S H O P O N L I N E @ W W W . A G S P R A Y . C O M
11
1. Wipe grease fitting with a clean cloth before greasing
to prevent injecting dirt and grit into joint.
2. Replace and repair broken fittings immediately.
3. If a fitting will not take grease, remove and clean
thoroughly. Also clean lubricant passageway.
Replace fitting if necessary.
*Note: Grease 20 points 8 hours or daily. Along
with 2 points per coulter. Hubs and spindles should
be greased biannually.
*Note: It is best to grease the machine at the end
of the day to ensure that fertilizer/chemicals do not
have time to start corroding parts.
L/R GREASE LOCATIONS
Apply adequate grease to the following:
1. L/R Main Wing Hinge (Fig. 20b)
2. L/R Flip Wing (35’) (Fig. 20c)
3. Coulter Pivots (Fig. 20d)
4. Parallel Hinge Bushings (Fig. 20a)
5. Piston Pump (Refer to pump operators manual)
1
2
2
3
3
GREASING
FIG. 7a
4
4
4
4
FIG. 7b
FIG. 7c
FIG. 7d