background image

© Copyright LOTRONIC 2012                                      IPAR-136 

Page 1 

 

 

 

 

 

 

 

 

O

O

U

U

T

T

D

D

O

O

O

O

R

R

 

 

L

L

E

E

D

D

 

 

P

P

R

R

O

O

J

J

E

E

C

C

T

T

O

O

R

R

 

 

P

P

R

R

O

O

J

J

E

E

C

C

T

T

E

E

U

U

R

R

 

 

A

A

 

 

L

L

E

E

D

D

S

S

 

 

E

E

X

X

T

T

E

E

R

R

I

I

E

E

U

U

R

R

E

E

 

 

 

 

 

 

 

 

IPAR

 

136

 

 
 

GB

 ‐ 

INSTRUCTION

 

MANUAL

 

F

 ‐ 

MANUEL

 

D’UTILISATION

 

 

 

 

 

Summary of Contents for IPAR 136

Page 1: ...IC 2012 IPAR 136 Page 1 O OU UT TD DO OO OR R L LE ED D P PR RO OJ JE EC CT TO OR R P PR RO OJ JE EC CT TE EU UR R A A L LE ED DS S E EX XT TE ER RI IE EU UR RE E IPAR 136 GB INSTRUCTION MANUAL F MANU...

Page 2: ...ectric shock when touching live wired 2 Never look directly into the light source as sensitive persons may suffer an epileptic shock 3 Please be aware that damages caused by manual modifications to th...

Page 3: ...dependent switch so that you can turn on or turn off the light randomly Note the ground wire yellow green double color wire must be safely connected the electrical installation must be in accordance w...

Page 4: ...S MENU BACK TO THE MAIN MENU AUTO FUNCTION CHOOSE AUTO PRESS ENTER TO AUTO MODE PRESS UP DOWN TO CHOOSE THE BUIL IN PROGRAM OR EDIT PROGRAM PRESS MENU BACK TO THE MAIN MENU Key code UP DOWN UP DOWN EN...

Page 5: ...LAV PRESS MENU BACK TO THE MAIN MENU DMX FUNCTION DMX ADDRESS SETTING CHOOSE DMX PRESS ENTER PRESS UP DOWN TO CHOOSE 1 512 VALUE PERS FUNCTION DMX OPERATING MODE DMX512 CHANNELS PERS CHOOSE PERS PRESS...

Page 6: ...OSE CURR OR TOP CHOOSE CURR PRESS ENTER WILL SEE THE VALUE IT S THE VALUE OF PROTECT TEMPERATURE PRESS MENU GO BACK CHOOSE TOP PRESS ENTER TO SET THE PROTECT TEMPERATURE Default 85 PRESS UP DOWN EDIT...

Page 7: ...RECEIVING PLEASE CUT OFF THE POWER AND RECEIVE AGAIN REST KEY CODE UP DOWN UP DOWN ENTER ID ID address setting ENTER press UP DOWN to choose ON to allow ID address function OFF close ID address functi...

Page 8: ...P DOWN TO CHOOSE VALUE 0 255 NOTE WHEN DMX channels set as STAG channel 6 can call out the 11 kind whites CAL2 FUNCTION COLOR DEVIATION CORRECTING SETTING CHOOSE CAL2 PRESS ENTER TO RGBW PRESS ENTER T...

Page 9: ...10 NO STROBE 11 255 SPEED OF STROBE 255 faster 7 0 20 NO FUNCTION 21 30 Build in program 1 every 10 numbers as a program 110 120 Build in program 10 121 130 Edit in program 1 every 10 numbers as a pro...

Page 10: ...ANNEL VALUE FUNCTION 1 0 255 MASTER DIM 2 0 255 RED 3 0 255 GREEN 4 0 255 BLUE AR1 S CHANNEL MODE CHANNEL VALUE FUNCTION 1 0 255 MASTER DIM 2 0 255 RED 3 0 255 GREEN 4 0 255 BLUE 5 0 10 NO STROBE 11 2...

Page 11: ...W 0 111 130 R up G 0 B 100 W 0 131 150 R 100 G 0 B down W 0 151 170 R 100 G up B up W 0 171 190 R down G down B 100 W 0 191 200 R 100 G 100 B 100 W 100 201 255 Color temperature Can Adjust by CAL1 Ev...

Page 12: ...s of the device have to be tightly connected and must not be corroded There must not be any deformations on the housing glass pane fixations and installation spots The electric power supply cables mus...

Page 13: ...r 36 x 1W RGB LEDs 12R 12G 12B Life time led 50000 hours IP norm IP 65 Working environment indoor Outdoor Voltage AC 100 240V 50 60Hz Power 60W Dimensions 200 x 200 x 250mm N W 2kg Electric products m...

Page 14: ...orsqu il n est pas utilis ou avant de le nettoyer Ne tirez que sur la fiche jamais sur le cordon Lorsque le cordon d alimentation ou un coupleur d appareil est utilis comme dispositif de d connexion c...

Page 15: ...vu qu il y ait suffisamment d espace pour assurer une ventilation suffisante Lorsque vous installez l appareil choisissez un emplacement qui permet d acc der facilement l appareil afin d effectuer l e...

Page 16: ...e Utilisez du c ble double blindage Le diam tre du conducteur de chaque c ble doit tre d au moins 0 5mm PANNEAU DE CONTROLE MENU ENTER UP DOWN Menu description FONCTION STAT MODE MANUEL S lectionnez S...

Page 17: ...internes soit les programmes dit s Appuyez sur MENU pour revenir au menu principale FONCTION RUN MODE MA TRE ESCLAVE S lectionnez RUN puis appuyez sur ENTER Utilisez les boutons UP DOWN pour choisir e...

Page 18: ...sur UP DOWN pour s lectionner la valeur ID 1 66 FONCTION TEMP PROTECTION SURCHAUFFE S lectionnez TEMP puis appuyez sur ENTER Utilisez UP DOWN s lectionner soit CURR soit TOP s lectionnez CURR puis app...

Page 19: ...AMME S lectionnez EDIT puis pressez ENTER Appuyez sur ENTER pour choisir les param tres Utilisez les boutons UP DOWN pour choisir le num ro de programme la sc ne et la valeur voir dans la partie Exemp...

Page 20: ...de correction des couleurs ENTER Appuyez sur UP DOWN pour choisir ON pour autoriser la fonction de correction des couleurs OFF pour annuler La correction des couleurs se fait dans la fonction CAL2 PO...

Page 21: ...ez sur ENTER pour RGBW Appuyez ENTER pour choisir le rouge Red le vert Green le bleu Blue Appuyez UP DOWN pour choisir la proportion de couleurs 25 255 FONCTION KEY PROTECTION BOUTON S lectionnez KEY...

Page 22: ...55 CHANGEMENT COULEURS 6 0 10 PAS DE STROBE 11 255 STROBE de lent rapide 7 0 20 Pas de fonction 21 30 Programme interne 1 110 120 Programme interne 10 121 130 Programme dit 1 211 220 Programme dit 10...

Page 23: ...L VALEUR FONCTION 1 0 255 Dimemr master 2 0 255 Rouge 3 0 255 Vert 4 0 255 Bleu AR1 S CANAL VALEUR FONCTION 1 0 255 Dimemr master 2 0 255 Rouge 3 0 255 Vert 4 0 255 Bleu 5 0 10 Pas de strobe 11 255 St...

Page 24: ...tres SCENE R G B W ST T F EFFECT SC 01 255 0 0 0 0 2 2 Le rouge s allume lentement 2 secondes SC 02 0 0 0 0 0 2 2 Le rouge s teint lentement SC 03 0 255 0 0 0 4 2 Le vert s allume lentement 2 seconde...

Page 25: ...maximale et de prolonger sa dur e de vie Utilisez un produit de nettoyage vitre de bonne qualit et un chiffon doux pour nettoyer l appareil Ne pas utiliser d alcool ou de solvants chimiques pour nett...

Reviews: