background image

© Copyright LOTRONIC 2015                                     MINIBEAM32 

Page 4 

operated in any way different to the one described in this manual, the product may suffer damages and the 
guarantee becomes void. 

 

RIGGING 

This fixture may be mounted in any position, provided there is adequate room for ventilation 
It is important never to obstruct the fan or vents pathway.   
When selecting installation location, take into consideration lamp replacement access and routine maintenance.   
Safety cables must always be used. 
Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperature changes or 
restricted ventilation. 
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer 
or his service agent or a similar qualified person in order to avoid a hazard. 
 

INSTALLATION INSTRUCTIONS 

Installation/replacement of lamp 

Do not turn the unit on if no lamp is fitted or if the lamp is burnt out.   
Disconnect from mains during lamp installation 
Please note: Under normal operating conditions, the housing may reach 60°C. 
The lamp becomes very hot during operation. When you switch the lamp off, don’t unplug it from the mains; Wait at 
least for 15 minutes to let the lamp cool down otherwise you might cause a high voltage discharge, short-circuit or 
burn out components on the PCB. 
Make sure the installation position is stable before you fix the light. When the light is reverse hanging, make sure the 
light will not fall from the truss. Pass a safety cable through the truss and bracket of the light as an extra support to 
avoid the light to fall down. Don’t access to the work area during mounting. Periodically check if the safety cable has 
fretted away or clamp is loosened. We cannot be held responsible for inadequate fastening and installation of    the 
unit. It is not recommended to use the lamp constantly for more than 10 hours.   
 

Power Supply and Signal Cable Connection 

1. Mains Power connection 
The exclusive plug should be used between the connection of unit and power. Please ensure that the rated voltage 
and frequency are accordance with the power supply. The required input voltage and frequency are: 220-240V / 
50-60Hz 
We suggest that every light has an independent switch so that you can turn on or turn off the light randomly. 
Note: the ground wire (yellow/green double-color wire) must be safely connected, the electronic installation must be 
in accordance with the related standards

 

CAUTION

: When installing the device, make sure there is no highly inflammable material within a distance of 

min.5m! 
 
2. Connection of Signal Cable 
You can use the 3-pin XLR cable to connect the output socket of the master and the input socket of the slave light. 
Connect the DIGITAL OUT socket of the master and the IN socket of the slave light, then, connect the OUT socket to 
the IN socket of the next light. Ordinal to connect all the lights as below: 

IN

O U T

IN

O U T

O U T

IN

1

2

3

D

M

X

 

 

I

N

D

M

X

 

 

O

U

T

 

Summary of Contents for 15-1927

Page 1: ...1 D DM MX X B BE EA AM M L LE ED D M MO OV VI IN NG G H HE EA AD D L LY YR RE E A A L LE ED D B BE EA AM M D DM MX X MINIBEAM32 15 1927 GB INSTRUCTION MANUAL F MANUEL D UTILISATION D BEDIENUNGSANLEITU...

Page 2: ...the lamps Prior to moving or handling the light effect the unit MUST be SWITCHED OFF and cool down for at least 10 minutes The lamps are not covered by the warranty Thank you VORSICHT Nicht die Lampen...

Page 3: ...visibly damaged to such an extent that their effectiveness is impaired for example by cracks or deep scratches The lamp shall be changed if it has become damaged or thermally deformed CAUTION 1 Be ver...

Page 4: ...before you fix the light When the light is reverse hanging make sure the light will not fall from the truss Pass a safety cable through the truss and bracket of the light as an extra support to avoid...

Page 5: ...hannel 13 channels DMX512 Pan scan 540 16 bit Tilt scan 240 16 bit LCD display OPERATION Address To choose the DMX address of the device when the operating mode is DMX Workmod To choose the operating...

Page 6: ...l glass detergent and soft cloth to clean the light It s not allowed to use alcohol or chemical solvent The inner part of the light should be cleaned by vacuum cleaner at least once a year When the li...

Page 7: ...FICATIONS Voltage 220 240V 50 60Hz Led 1x 32W RGBW 4 in 1 Dimensions 176 x 126 x 288mm N W 3 5kg Electric products must not be put into household waste Please bring them to a recycling centre Ask your...

Page 8: ...mal et cesse apr s quelques instants Lorsque le cordon d alimentation ou un coupleur d appareil est utilis comme dispositif de d connexion ce dispositif doit rester facilement accessible Si un interru...

Page 9: ...n qualifi afin d viter tout risque d lectrocution INSTALLATION Installation remplacement de la lampe Ne pas mettre l appareil sous tension sans lampe ou lorsque la lampe est d fectueuse D branchez la...

Page 10: ...40 16 bit Afficheur LCD UTILISATION Address pour choisir l adresse DMX de l appareil en mode DMX Workmod Permet de choisir le mode de fonctionnement de la lyre DMX Auto ou musical sound Pt sett R glag...

Page 11: ...t d installation ne doivent pr senter aucune d formation 3 Les cordons d alimentation lectrique ne doivent pr senter aucun dommage ni signes d usure L installateur doit respecter toutes les consignes...

Page 12: ...toyez l int rieur de l appareil une fois par an au moyen d un aspirateur Si la lampe ne fonctionne pas v rifiez si le fusible a saut Si c est le cas remplacez le fusible par un neuf qui pr sente exact...