Safety
MAXILYZER NG Plus
5
2
Safety
2.1
Intended use
The flue gas analysis computer MAXILYZER NG Plus is exclusively
suitable for the use in the following application areas:
•
Professional settings and control-measurements at all smallfir-
ings-facilities (low temperature- and burner-value-boilers and -
thermal) for gas and oil applicable.
•
With a second CO measuring cell (option) you can also use the
instrument for facilities for solid fuels as wood, coal etc.
•
Measurements at bivalent and power modulatory communal
heating stations.
Any use other than the use explicitly stated in this instruction manual
is not permitted.
2.2
Predictable incorrect application
The flue gas analysis computer MAXILYZER NG Plus must never be
used in the following:
•
Hazardous areas (ex)
If the device is operated in hazardous areas, sparks may cause
deflagrations, fires or explosions
•
Use as a safety (alarm) unit or continuous measuring device.
2.3
Safe handling
This product represents state-of-the-art technology and is manufac-
tured in accordance with the pertinent safety regulations. Each unit is
subjected to a function and safety test prior to despatch.
Operate the product only when it is in perfect condition. Always
observe the instruction manual, all pertinent local and national
directives and guidelines as well as health and safety regula-
tions and directives regarding the prevention of accidents.
Perform an overall visual inspection of the measuring device
(including any accessories) prior to each operation of the MAX-
ILYZER NG Plus in order to ensure proper operation of the de-
vice.
Voltage supply
Verify that the device is suitable for your mains. Make sure you
have the correct mains voltage when connecting the device.
This is a device of safety class 1, i.e. it has an earth connection. Any
interruption of the protective conductor inside or outside the device
or disconnecting the protective conductor connection may cause