27
2.Please contact with local dealer if error remains the same after
several reset.
IntFaultG
1.Electricity grid abnormal
2.DCI too high
1.After electricity grid returns to normal, the mac
hine will
automatically restart.
2.Please contact with local dealer if error remains the same after
several reset.
IntFaultJ
Relay failure
Please contact with local dealer if error remains the same after
several reset.
IntFaultK
1.Electricity grid abnormal
2.Bus differential fault
1.After electricity grid returns to normal, the mac
hine will
automatically restart.
2.Please contact with local dealer if error remains the same after
several reset.
IntFaultL
1.Electricity grid abnormal
2.Low Bus voltage fault
1.After electricity grid returns to normal, the machine
will
automatically restart.
2.Please contact with local dealer if error remains the same after
several reset.
IntFaultM
1.Electricity grid abnormal
2.High Bus voltage fault
1.After electricity grid returns to normal, the machine will
automatically
restart.
2.Please contact with local dealer if error remains the same after
several reset.
IntFaultN
Internal hardware fault
Please contact with local dealer if error remains the same after
several reset.
IntProtectA
Offset current protection
Please contact with local dealer if error remains the same after
several reset.
IntProtectB
Relay protection
Please contact with local dealer if error remains the same after
several reset.
IntProtectC
Over current protection
Please contact with local dealer if error remains the same after
several reset.
IntProtectD
1.PV side high current
2.Boost over current protection
1.Adjust the panel configuration to lower the input current.
2.Please contact with local dealer if error remains the same after
several reset.
IntProtectE
1.Electricity grid abnormal
2.Soft start overtime protection
1.After electricity grid returns to normal, the mac
hine will
automatically restart.
2.Please contact with local dealer if error remains the same after
several reset.
IntProtectF
When direct current is at low
voltage, Soft start overtime
protection
Please contact with local dealer if error remains the same after
several reset.
IntProtectG
Bus voltage differential protection Please contact with local dealer if error remains the same after
several reset.
IntProtectH
Low Bus voltage protection
Please contact with local dealer if error remains the same after
several reset.
IntProtectI
High Bus voltage protection
Please contact with local dealer if error remains the same after
several reset.
IntProtectJ
Inverter bridge protection
Please contact with local dealer if error remains the same after
several reset.
IntProtectK
Bus hardware overvoltage
Please contact with local dealer if error remains the same after