56 Maintenance
4510012 - REV F – 220621
External Cleaning
The exterior of the GEN S may require occasional cleaning due to environmental contaminants.
To clean the external components, gently wipe them with a clean cloth and cleaning spray.
Manual Cleanout
Every 3 months, a manual cleanout of the Boiler Tank and Heating Elements is necessary.
ATTENTION:
Do not use boiler cleaning compounds.
Needed to Perform a Manual Cleanout:
•
Long-Handled, Soft Wire Brush
•
Teflon Paste
•
Heat-resistant Work Gloves
•
Safety Glasses/Goggles
•
New Gasket
To Perform a Manual Cleanout:
Perform the blowdown procedure to empty the Boiler of all water (see “Blowdown
Procedure” on page
) and allow the system at least 20 minutes to cool afterward.
Open the Electrical System Enclosure.
Electrical
System
Enclosure
Boiler
Electrical
Cabinet