20
EU-20-OI-v-1.2 gb. 28.07.14.docx
3.7 Gripper load
3.8 Electrical interface
Connecting cable
Strand colour
Assignment
white
24VDC (1A)
brown
0 VDC (GND)
yellow
Digital input (DI)
Edge change 0
24V: extend
Edge change 24V
0V: retract
green
Digital output 1: (DO 1) (1 = retracted on resistance)
grey
Digital output 2: (DO 2) (1 = extended)
Figure 4: Table of the connecting cables