5.6 Emitter evaluation and analog input [X6]
Parameters
Value
Inputs for Hall sensors
Type
Single ended
Inputs
H1, H2, H3
Input voltage
5 V
max. pulse frequency
(per track)
100 kHz
Inputs for encoder
Type
Single ended
Inputs
A, B, Inx
Input voltage
5 V
max. pulse frequency
(per track)
300 kHz (push-pull)
100 kHz (open collector)
Supply voltage for Hall sensors and encoder
Output voltage
5 V +/-5 %
max. load
200 mA
Analog input
Type
Single ended
Measuring range
0…10 V
Resolution
10 bit
Input impedance
ca. 20 kOhm