32
– 66
Operating instructions EN
◼
SE-24
◼
01.06.2022
◼
V1.5
7.1.3 Profibus connection
The Profibus connection on the SE-24 servo controller is carried out as a 5 pole M12
plug or socket (b-coded) according to EN 50170.
7.1.3.1 Profibus IN [X2b]
Figure 6: View of the connection [X2b]
7.1.3.2 Profibus OUT [X3b]
Figure 7: View of the connection [X3b]
For the functional description of the input and output data please see the document:
SE-24 Profibus Manual
X2b, Profibus IN
Flush-type plug, 5 pole M12, b-coded
Phoenix: 1419661
SACC-DSI-M12MSB-5CON-M16/0,5
Pin
Designation
Specification
1
n.c.
2
A line (R/TxD-N)
Data line -
3
n.c.
4
B line (R/TxD-P)
Data line +
5
n.c.
X3b, Profibus OUT
Flush-type socket, 5 pole M12, b-coded
Phoenix: 1419674
SACC-DSI-M12FSB-5CON-M16/0,5
Pin
Designation
Specification
1
+5V (VCC_ISO)
+5 V supply
2
A line (R/TxD-N)
Data line -
3
ISOGND
Data ground
4
B line (R/TxD-P)
Data line +
5
n.c.