AEV MMS 3000 Manual Download Page 2

  

AEV MMMS3000 -  ON AIR CONSOLE

     

 

 

  AEV Broadcast Srl

, via della Tecnica 33 – 40050 Argelato (BO) Italy 

    Web site www.aev.eu     e-mail  [email protected]             

 

2

 

warranty does not cover faults provoked by carelessness, natural causes and parts subject 
to wear. In addition, the cost of shipment is not covered. The warranty will be voided if the 
equipment is mishandled. 

 

Technical Support 

If you require technical support, contact AEV SERVICE giving a clear and concise account of 
your speciic problem. Quote the serial number of your equipment by referring to the AEV 
nameplate attached to the equipment itself as this is the most important piece of information 
to be provided. 
Telephone: 39+051 6630904 Fax: 39+051 893605 
 

Factory Service and Repairs 

If problems arise while the equipment is being installed, consult this manual and check that 
the installation is being carried out properly. If the problems still cannot be solved, call the AEV 
SERVICE Department for further information. If the problem is a minor one we can a telephone 
call will probably sufice. If, on the other hand, the equipment is to be shipped to AEV for 
service or repairs.  
 

Shipping Instruction 

When shipping the equipment to AEV, use the original package in order to be certain that it will 
be fully protected during handling. If you need the original package, call us for a new one. 
If you ship the equipment in a different packing container, take care to provide a double 
package by interposing padding material between the two containers in order to fully protect 
the equipment during shipment. The package should be marked “FRAGILE” in red. 
Remember that the RMA number must be clearly visible on the package. If it is not, the 
equipment will not be accepted. 
 

IMPORTANT: 

Carefully read this paragraph as it contains important instructions concerning 

operator safety and directions regarding the installation, operation and maintenance of the 
equipment. 
Failure to observe the safety instructions and information given in this manual 

constitutes an 

infringement of the safety rules and design specifications provided for this piece of 
equipment

AEV Broadcast Srl declines all responsibility 

if any one of the safety rules given herein is 

not observed. 

AEV Broadcast Srl declines all responsibility 

if the end-user resells the product. 

The equipment is to be used by people capable of operating it in a trouble-free manner and 

it 

is assumed that they are aware of the following safety rules. 

• Keep this manual with the utmost care and close at hand so that it can be consulted 
whenever needed 
• After unpacking the equipment, check it for condition. 
• Avoid banging the equipment. 
• The packing material (plastic bags, polystyrene, nails, etc.) must never be left within the 
reach of the children, as 

these items are potential sources of danger

• Do not use the equipment in places where the temperature is not within the recommended 
range, as speciied by the manufacturer. 
• Before connecting the equipment, make sure the nameplate specifications correspond to the 
mains electricity supply (the nameplate is located on the equipment enclosure). 
• Do not remove the sticker from the equipment as it contains important specifications and the 
relevant serial number. 
• To join the equipment to the mains supply, use the power cord purchased with the 
equipment. 
• The equipment must be used only for the purpose it was designed for. 
• Abuse or misuse of the equipment is 

extremely dangerous 

for people, pets and property. 

The manufacturer declines all responsibility for damage and injury resulting from 

improper 

use 

and 

mishandling

Summary of Contents for MMS 3000

Page 1: ...roadcast Srl via della Tecnica 33 40050 Argelato BO Italy Web site www aev eu e mail info aev eu 1 AEV MMS 3000 On Air Broadcast Console Guarantee The equipment is warranted for a period of 2 years from the date of invoice ex works The ...

Page 2: ... equipment will not be accepted IMPORTANT Carefully read this paragraph as it contains important instructions concerning operator safety and directions regarding the installation operation and maintenance of the equipment Failure to observe the safety instructions and information given in this manual constitutes an infringement of the safety rules and design specifications provided for this piece ...

Page 3: ...own fuses inside the power supply indicate that there may be a fault in the power supply itself The fuses must be replaced by qualiied and authorised persons It is advisable to call your nearest dealer Call your dealer for any repairs and be certain original spare parts are used Failure to observe this rule may adversely affect the safety level of your equipment The equipment is to be connected to...

Page 4: ...ing operation 9 Telephone module 10 Master module 11 General functions 12 Insert 12 Phantom 12 Start 12 Stop 12 Slider 12 Tally 12 OUT AUX Coniguration 12 Direct controls 12 Control Room Area 12 Control Studio Area 13 Headsets Area 13 Using the Talk Back 13 Talk Back from Control Room Master control 13 Talk Back from Control Studio DJ 13 Mic Line Input Insert Pin out Setup 14 Line Line Input Pin o...

Page 5: ...Micro inputs Insert only for Micro inputs Bus assignment Tally 1 Logic control for the START STOP functions Intercom Outputs PGM Analog stereo UTL Analog Stereo CONTROL ROOM Analog Stereo CONTROL STUDIO Analog Stereo HEADPHONES Analog Stereo External controls Remote Fader with logic controls TB On Off Cough GPI Opto isolated logic inputs GPO Opto isolated logic outputs ON AIR Tally TalkBack Output...

Page 6: ...r adjusting the input level from 0 to 30 dB for very low volume microphones 4 Dip switch for setting up the microphone channel Insert Talk Back Mute Tally and Remote 5 GAIN Potentiometer 6 TREBLE Potentiometer 7 BASS Potentiometer 8 BALANCE L R Potentiometer 9 Button for selecting the input source Micro or Line 10 Button for routing the channel to the PGM bus 11 Button for routing the channel to t...

Page 7: ... 15 pole Line B input connectors for the pin out coniguration see the technical section 3 Dip switch for setting up the microphone channel Insert Talk Back Mute Tally and Remote 4 GAIN Potentiometer 5 TREBLE Potentiometer 6 BASS potentiometer 7 BALANCE L R Potentiometer 8 Buttons for selecting the input source Line A or Line B 9 Button for routing the channel to the PGM bus 10 Button for routing t...

Page 8: ... 1 2 3 5 PRIVATE Enable S S STAB S S IMPULS ST Mute CR Mute CS CR Enable With the channel in a STOP position the audio signalis routed to the TEL BUS private phone call With the channel in a STOP position press the TB and the microphone signal is routed to the Control Room Headsets and Speaker outputs while the Control Studio Mute is disabled When the channel switches to START the Control Room out...

Page 9: ...n of the module to be enabled pressed then switch the Mixer on The Module is communication enabled via the TB button of the Master on the Control Room output ON AIR TALLY Hold the PGM button of the module to be enabled pressed then switch the Mixer on The Module is enabled to manage the Tally logic output Instructions on startup B Input Modules or CALL Phone Modules on The optional remote control ...

Page 10: ...hannel to the PGM bus 8 Button for assigning the channel to the UTL bus 9 Button for assigning the channel to the AUX bus 10 Button for enabling CUE pre listening 11 Fader Operation When the CALL Led is lashing this means that a telephone call is being received Press the HOOK button to hook up the telephone line the respective Led lights up To disable the telephone line press the HOOK button again...

Page 11: ...hed VU Meters 19 Button for selecting the EXT1 input to be sent to the Control Room 20 Button for selecting the EXT2 input to be sent to the Control Room 21 Button for selecting the Master PGM output to be sent to the Control Room 22 Button for selecting the Master AUX output to be sent to the Control Room 23 Button for selecting the Master UTL output to be sent to the Control Room 24 Button for s...

Page 12: ...vailable on the mixer two external analog inputs EXT 1 and 2 a PGM analog output a UTL analog output an AUX analog output Direct controls Control Room Area The Control Room audio output level may be adjusted via the C Room potentiometer located on the panel EXT1 When the EXT1 button is pressed the following functions are set on the EXT1 input signal is sent to the Control Room output and the funct...

Page 13: ... output and the function previously set on the Control Studio bus is disabled TB When the TB talk back button is pressed the signal of the enabled microphone is sent to the Control Studio output Notice the Microphone signal replaces the signal that up to that moment had been sent to the pre selected output When the TB button is released all switches back to the previous status Any PRIVATE conversa...

Page 14: ...AEV MMMS3000 ON AIR CONSOLE AEV Broadcast Srl via della Tecnica 33 40050 Argelato BO Italy Web site www aev eu e mail info aev eu 14 Mic Line Input Insert Pin out Setup ...

Page 15: ...AEV MMMS3000 ON AIR CONSOLE AEV Broadcast Srl via della Tecnica 33 40050 Argelato BO Italy Web site www aev eu e mail info aev eu 15 Line Line Input Pin out ...

Page 16: ...AEV MMMS3000 ON AIR CONSOLE AEV Broadcast Srl via della Tecnica 33 40050 Argelato BO Italy Web site www aev eu e mail info aev eu 16 Mic Input connection ...

Page 17: ...AEV MMMS3000 ON AIR CONSOLE AEV Broadcast Srl via della Tecnica 33 40050 Argelato BO Italy Web site www aev eu e mail info aev eu 17 Line Input connection 9 2 3 15 7 6 9 2 3 15 7 6 ...

Page 18: ...AEV MMMS3000 ON AIR CONSOLE AEV Broadcast Srl via della Tecnica 33 40050 Argelato BO Italy Web site www aev eu e mail info aev eu 18 TELEPHONE Pin out Setup 7 6 ...

Page 19: ...y Web site www aev eu e mail info aev eu 19 GPI GPO Pin out Pulse commands pin n Mic Line 5 Vdc 2 3 4 11 1 9 6 7 IN START A 5 Vdc GND OUT START A IN STOP A IN HOOK START STOP HOOK GND 13 5 Telephpone 5 Vdc N C N C PGM GND Tally 10 12 14 SHIELD SHIELD SHIELD OUT STOP A CALL 15 8 PGM UTL AUX ...

Page 20: ...AEV MMMS3000 ON AIR CONSOLE AEV Broadcast Srl via della Tecnica 33 40050 Argelato BO Italy Web site www aev eu e mail info aev eu 20 Master Pin out ...

Page 21: ...AEV MMMS3000 ON AIR CONSOLE AEV Broadcast Srl via della Tecnica 33 40050 Argelato BO Italy Web site www aev eu e mail info aev eu 21 Master Output connection PGM UTL C STUDIO C ROOM ...

Page 22: ...AEV MMMS3000 ON AIR CONSOLE AEV Broadcast Srl via della Tecnica 33 40050 Argelato BO Italy Web site www aev eu e mail info aev eu 22 Master Input connection EXT 1 EXT 2 ...

Page 23: ... control Connector DSUB 15 pole female LINE INPUT Input configuration Electronically balanced Input Impedance 10 KΩ 600 Ω wired selectable Input Level 12 dBu Digital adj step 0 5 dB Headroom 18 dBu 100 mm Fader control VCA Digital controlled In Start Stop control Out Start Stop control Connector DSUB 15 pole female TELEPHONE HYBRID MODULE Input configuration Opto coupled Input Impedance 600 Ω Bala...

Page 24: ...or DSUB 9 pole female C Studio Mut Output Level Range 6 dBu Connector DSUB 9 pole female C Room Mut Output Level Range 6 dBu Connector DSUB 9 pole female HEADPHONES C Room no Muted Configuration Type Stereo unbalanced Output Impedance 50 Ω Connector JACK 6 3 mm Output Level Range 6 dBu LOGIC INPUT Configuration Opto coupled with internally 330 ohm protection Max Voltage input 5 Vdc for 10 mA input...

Page 25: ...e microphone channel ON fader at 0 dB input sensitivity at 40 dB 200 Ω source Output Noise better than 86 dB A Weighted 10 Hz 23 KHz 75 dB CCIR Wght with one line channel ON fader at 0 dB input sensitivity at 0 dB Output Noise better than 89 dB A Weighted 10 Hz 23 KHz 78 dB CCIR Wght with all input channel OFF DISTORTION T H D Microphone Input to program output Less than 0 018 Line Input to progra...

Reviews: