– Battery Ratings Charts   

 

 

8.1 Japanese Industrial Standard (JIS#) CCA Ratings 
 

 

                             

Battery Model (JIS#) 

 

    CCA    Rating 

                             

Battery Model (JIS#

 

  CCA    Rating 

             

NEW 

                 

OLD 

 
WET 

     
MF 

CMF 
SMF 

           

NEW 

                 

OLD 

 
WET 

     
MF 

CMF 
SMF 

26A17R 

 

200 

 

 

48D26R 

N50 

280 

360 

420 

26A17L 

 

200 

 

 

48D26L 

N50L 

280 

360 

420 

26B17R 

 

200 

 

 

50B24L 

NT80-S6L 

390 

 

 

26B17L 

 

200 

 

 

50B24R 

NT80-S6 

390 

 

 

26A19R 

12N24-4 

200 

220 

264 

50D20R 

 

310 

380 

480 

26A19L 

12N24-3 

200 

220 

264 

50D20L 

 

310 

380 

480 

28A19L 

NT50-N24L 

250 

 

 

50D23R 

85BR60K 

500 

 

 

28B17R 

 

245 

 

 

50D23L 

85B60K 

500 

 

 

28B17L 

 

245 

 

 

50D26R 

50D20R 

 

370 

 

28B19R 

NS40S 

245 

 

 

50D26L 

50D20L 

 

370 

 

28B19L 

NS40LS 

245 

 

 

55B24R 

NX100-S6 

435 

420 

500 

28A19R 

NT50-N24 

250 

 

 

55B24L 

NX100-S6L 

435 

420 

500 

32A19R 

NX60-N24 

270 

295 

 

55B24RS 

NT80-S6S 

430 

420 

500 

32A19L 

NX60-N24L 

270 

295 

 

55B24LS 

NT80-S6LS 

430 

420 

500 

32B20R 

NS40 

270 

 

 

55D23R 

 

355 

480 

500 

32B20L 

NS40L 

270 

 

 

55D23L 

 

355 

480 

500 

32C24R 

N40 

240 

325 

400 

55D26L 

N50ZL 

350 

440 

525 

32C24L 

N40L 

240 

325 

400 

55D26R 

N50Z 

350 

440 

525 

34B17R 

 

280 

 

 

60D23R 

 

520 

 

 

34B17L 

 

280 

 

 

60D23L 

 

520 

 

 

34B19R 

NS40ZA 

270 

325 

400 

65D23R 

 

420 

540 

580 

34B19L 

NS40ZAL 

270 

325 

400 

65D23L 

 

420 

540 

580 

34B19RS 

NS40ZAS 

270 

325 

400 

65D26R 

NS70 

415 

520 

625 

34B19LS 

NS40ZALS 

270 

325 

400 

65D26R 

NS70L 

415 

520 

625 

36B20R 

NS40Z 

275 

300 

360 

65D31R 

N70 

390 

520 

630 

36B20L 

NS40ZL 

275 

300 

360 

65D31L 

N70L 

390 

520 

630 

36B20RS 

NS40ZS 

275 

300 

360 

70D23R 

35-60 

490 

540 

580 

36B20LS 

NS40ZLS 

275 

300 

360 

70D23L 

25-60 

490 

540 

580 

38B20R 

NX60-N24 

330 

340 

410 

75D23R 

 

500 

520 

580 

38B20RS 

NT60-N24S 

330 

340 

410 

75D23L 

 

500 

520 

580 

38B20L 

NX60-24L 

330 

340 

410 

75D26R 

F100-5 

490 

 

 

38B20LS 

NX60-24LS 

330 

340 

410 

75D26L 

F100-5L 

490 

 

 

40B20L 

 

330 

 

 

75D31R 

N70Z 

450 

540 

735 

40B20R 

 

330 

 

 

75D31L 

N70ZL 

450 

540 

725 

42B20L 

 

330 

 

 

80D23R 

 

580 

 

 

42B20RS 

 

330 

 

 

80D23L 

 

580 

 

 

42B20LS 

 

330 

 

 

80D26R 

NX110-5 

580 

580 

630 

46B24R 

NS60 

325 

369 

420 

80D26L 

NX110-5L 

580 

580 

630 

46B24RS 

NS60S 

325 

360 

420 

85B60K 

 

 

 

500 

46B24LS 

NS60LS 

325 

360 

420 

85BR60K 

 

 

 

500 

46B26R 

NS60 

360 

 

 

95D31R 

NX120-7 

620 

660 

850 

46B26L 

 

360 

 

 

95D31L 

NX120-7L 

620 

660 

850 

46B26RS 

 

360 

 

 

95E41R 

N100 

515 

640 

770 

46B26LS 

 

360 

 

 

95E41L 

N100L 

515 

640 

770 

46B24L 

NS60L 

325 

360 

420 

105E41R 

N100Z 

580 

720 

880 

Summary of Contents for BESA-12P

Page 1: ...BESA 12P User s manual 1 www aetool com AETOOL LTD BESA 12P V13 08 Battery Electrical System Analyser with integrated Printer USER MANUAL...

Page 2: ...Link 13 6 0 HELP Key 14 7 0 Battery Test 7 1 Start Testing 16 8 0 Battery Rating Charts 8 1 Japanese Industrial Standards JIS Rating Chart 29 8 2 DIN EN Standards Rating Charts 30 8 3 YUASA Battery R...

Page 3: ...Analyses the condition of the electrical return circuit contacts resistance which were connected to the engine or chassis body from the battery terminal with results and recommendations display after...

Page 4: ...ipped with an USB port to be connected to the PC to store the results or have it printed out from normal computer printer 1 2 Specifications Operating Voltage 9V 15V DC max Analysing Capacity Amps CCA...

Page 5: ...es they are hazardous that can lead to death To protect your eyes from propellant object such as caustic liquids always wear safety eye protection Fuel and battery vapors are highly flammable DO NOT S...

Page 6: ...m 9V 15V DC and should not be tested on 24V directly It will cause damage the unit For 12V x 2 batteries in series or parallel disconnect the connections and test them individually Battery that has ju...

Page 7: ...d exercise caution Do not allow battery electrolyte to mix with salt water Even small quantities of this combination will produce chlorine gas that can KILL you Whenever possible please follow the man...

Page 8: ...the battery and charger manufacturer s procedures for connecting and disconnecting cables and other steps to minimize the possibility of an explosion or incorrectly charging the battery You should tur...

Page 9: ...rical System Analyser 4 1 BESA 12P 4 2 Keypad Functions Figure 1 Figure 2 3 6 8 1 2 4 7 5 Red Clamp to battery positive post Black Clamp to battery negative post USB port for connection to PC Printer...

Page 10: ...ery Ratings values mode press this key once will decrease the value by step of 5 units 4 Use this key to shift the selection tab to the left item OR when it is in the keying in Battery Ratings values...

Page 11: ...e paper is about 20mm out when the printer cover is closed Figure 4b 5 2 Select Display Language To change the display language of the Analyser this can be done while on the wake up screen see fig 5 b...

Page 12: ...s If you find that LCD screen display is too bright or too dim and need to adjust its contrast then select LCD Brightness from the menu Fig 8 Once entered the display will show as in Fig 9 To increase...

Page 13: ...n you wish to connect BESA 12P to PC to print or store the results of the last tested vehicle Once the tester is connected to the PC with the USB cable provided select PC Link as in Fig 11 with key an...

Page 14: ...the menu screens as shown below Fig 13 and Fig 14 EXIT For Example If help is needed on Battery Test then press key on this item and the display will change to as shown Fig 15 Figure 13 Figure 15 Fig...

Page 15: ...ck to the main menu Fig 5 Let say if you need help on How to operate press key in this selection will get into the display as shown below Figure 16 Figure 17 Battery Test How to operate Voltage Batter...

Page 16: ...is still in the car Vehicle that was running has to have its engine OFF first and then switch ON the headlights for 30 seconds to remove the surface charge After the headlights had switched OFF let t...

Page 17: ...you select your choice from the Menu New Clear Memory Selecting this item will allow the tester to clear the last tested results stored in its memory and begin a new test Continue Testing Selecting t...

Page 18: ...inue Testing will proceed to the display below Fig 23 4 Pressing key once will scroll down to the next item if there is a need to select it 5 As an example Fig 23 the selected item was on Battery Test...

Page 19: ...the instructions as shown Fig 25 below 8 Wait until the surface charge removal had completed the analyser will advise as follows Fig 26 and then press key Figure 26 Figure 25 Figure 24 The Analyser is...

Page 20: ...SLI batteries e g normal Flooded types like Wet Low Maintenance Pb Ca Wet Standard Pb Pb Batteries If AGM Flat Spiral is selected then it will test Wet MF Maintenance Free Ca Ca AGM Gel Cell VRLA Ca...

Page 21: ...les shown below If it is selected under JIS Japanese Industrial Standard then the display will prompt you as shown Fig 29 below Refer to the battery model example 80D26L or NX110 5L on the Cold Cranki...

Page 22: ...CCA Note WET Wet Cell Type MF Maintenance Free Type SMF Closed or Sealed Maintenance Free 14 To enter the value 630 press key will increase the original value of 500 Fig 31 by step of 100 units to 60...

Page 23: ...results basing on the evaluation of the tested condition Good indicates the battery in good condition Replace indicates that the battery needs to be replaced If not the battery will fail anytime witho...

Page 24: ...ion in relation to its rating From the above example a 630 CCA rated battery measuring 406 CCA available power does not mean that the battery would pass a CCA test at 406 CCA The available power readi...

Page 25: ...ery at 0 F 18 C for 30 seconds while maintaining a voltage of at least 7 2 Volts for a 12V battery during cranking SAE The Society of Automotive Engineers Standard SAE has established Cold Cranking Am...

Page 26: ...f the results display is shown below Fig 35 To determine the condition of the tested Deep Cycle Batteries refer the Volts reading State of Charge should not fall below 12 60V when fully charged for Le...

Page 27: ...39 the Results shown To replace this meant that the battery need to be replaced as its internal plate resistance Int R is higher than 15 mOhm 15 Pressing the key at any moment will exit and return bac...

Page 28: ...N50Z 350 440 525 34B17R 280 60D23R 520 34B17L 280 60D23L 520 34B19R NS40ZA 270 325 400 65D23R 420 540 580 34B19L NS40ZAL 270 325 400 65D23L 420 540 580 34B19RS NS40ZAS 270 325 400 65D26R NS70 415 520...

Page 29: ...0 20L 1530 1250 8 2 DIN EN Standards Rating Chart Battery Model No Amps Battery Model No Amps DIN EN DIN EN 52805 180 240 55057 320 540 52815 180 240 55068 220 390 53517 175 300 55069 220 390 53520 15...

Page 30: ...6638 300 510 60026 440 720 56641 300 510 60038 500 760 55647 300 510 60044 500 760 56821 315 540 60527 410 680 56820 315 540 60528 410 680 56828 315 540 61017 400 680 57024 315 540 61018 400 680 57029...

Page 31: ...Battery Rating Chart 8 4 Rough CCA Guide Given below is a rough CCA ratings guide for any unknown battery model basing on the capacity of the vehicle Vehicle Capacity Approximate Battery CCA Rating 12...

Page 32: ...rrosion takes place very often If these contacts were no good then it will pose a lot of electrical problems to the vehicle To check the grounding condition this Analyser will measure the resistance f...

Page 33: ...the Grounding Test Fig 43 5 Press key will proceed to the display as follows Fig 44 Figure 42 Figure 43 Figure 44 Select Test Battery Test Grounding Test Starter Test Alternator Test Then press Enter...

Page 34: ...you have should unclamp the Black tester clip from the engine or chassis body and transfer to the battery negative terminal within 20 seconds time limit if not the testing procedure has to be repeated...

Page 35: ...isplay as follows Fig 49 12 If the measured resistance reading has gone beyond the limits then it will display the screen as follows Fig 50 Figure 48 Figure 49 Figure 50 Analysing Please wait Results...

Page 36: ...ow the right procedures during the testing it will display the results as follows Fig 51 below 14 To exit the program pressing the key at any moment will exit and return back to the main menu screen F...

Page 37: ...rop which indicates that it is weaker but still usable Whereas Figure C represents a very weak battery that can barely crank a car and is due to fail in the very near future As voltage profiles can in...

Page 38: ...continue and the display will show Fig 55 3 Switch the ignition key to ON and start cranking the engine until it starts Immediately after that press key and the results will show as follows Figure 55...

Page 39: ...when it detects that there is no drop in voltage it will display the following screen Figure 58 Figure 56 Figure 57 Figure 58 Result OK Min Volts 10 56V Volt Drop Normal Press Exit to main menu Result...

Page 40: ...fixed to the case of the alternator and these windings are static i e they don t rotate As the Rotor rotates its magnetic field cuts each Stator winding in turn this induces a current in each winding...

Page 41: ...harge of the battery controls amperage output of the alternator When the battery has a full charge the electro motive force of the voltage lowers the amperage to almost zero As the battery charge wear...

Page 42: ...oceed to the display below Fig 61 5 Pressing key to scroll down to the Alternator Test Fig 62 6 Press key to continue and the display will show Fig 63 Figure 61 Figure 62 Figure 60 Select Menu New Cle...

Page 43: ...w as below Fig 65 With the captured readings analysis can done by referring to the limits as indicated that MAX voltage should not exceed 15 0V max voltage at 3 000 RPM and MIN voltage should be more...

Page 44: ...to the battery to compensate for the added load This test is to check the alternator s behavior during loading 9 Continue from the previous test either Fig 66 67 or 68 proceed to the next step by pres...

Page 45: ...out 10 seconds and release the pedal The maximum and minimum voltages values will be captured Fig 70 With the captured readings analysis can done by referring to the limits as indicated that MAX volta...

Page 46: ...main menu screen Fig 62 12 0 View Last Test Results To view the results of the last test BESA 12P has to be connected to an external power source by either clamping its clips directly to a 12 Volt car...

Page 47: ...hown Fig 76 3 Pressing key once will scroll down to the View last Test Fig 77 below Figure 75 Figure 76 Figure 77 Select Menu New Clear Memory Continue Testing View last Test Setup Menu Then press Ent...

Page 48: ...Battery Good Measured 406 CCA Rating 630 CCA Volts 12 45 V Int R 6 72 mOhm Life 76 Results High Ohms The grounding resistance of the engine or car chassis is high Clean the cable contacts or replace...

Page 49: ...r has to be connected to a 12V battery in order to work with the mobile printer This is because it needs higher Amps to operate which the PC USB output is unable to provide To print just press key on...

Page 50: ...the proper driver for BESA 12P when connected If you have made the above error and wish to install the driver the second time you need to uninstall the previously installed driver first before starti...

Page 51: ...prompt you as shown below Click Finish Step 3 Then Plug BESA 12P on any of the USB port and the computer will start to locate the driver and it will pop up a message box as shown below Wait for awhil...

Page 52: ...by left clicking the and the display page will show as follows Step 6 Now link up BESA 12P with PC through the following procedures 1 On the Main Menu page Fig 83 below select Setup Menu by pressing...

Page 53: ...ss any other keys because the Analyser is already communicating with the PC 3 To confirm whether there is communication click on Get Data From Analyser tab and the Last Test Result will appear See exa...

Page 54: ...on this page if you wish to print out the results make sure that your printer is connected to the computer Click on PRINT tab and a text box will appear Select the right printer and click Print tab to...

Page 55: ...onsequential damages including lost profits in connection with the furnishing performance or use of this material This user manual tells how to use and perform the required procedures on vehicles Safe...

Page 56: ...ct with extreme heat Cables that have broken bent contact pins or subject to extreme stress or wear Physical damage to the product surface including scratches cracks or other damage to the display scr...

Reviews: