Chapter 4
LOAD AND TRANSPORT INSTRUCTIONS
-
20
-
English
C42
4146
000.fm
ID
M
4.9.
PNEUMATIC CONNECTIONS
For this operation, proceed in the follow-
ing way.
1 -Insert a flexible tube on the end of
the rubber fitting and fasten it with a
metallic screw clamp
(A)
.
2 -Check that the valve
(B)
is in the
"OPEN" position.
3 -Start pressure supply.
4 -Check that the pressure gauge indi-
cates at least 6 bar and use the
knob
(C)
to compensate any pres-
sure differences. Repeat this opera-
tion when the machine is running.
4.10. ELECTRICAL CONNECTIONS
Standard models work with a mains voltage of:
– 220/240V 1Ph-50/60 Hz
– 220/240V 3Ph-50/60 Hz
– 380/415V 3Ph+N-50/60 Hz
Proceed as follows for electrical connections.
1 -Check that the mains voltage (V) and frequency
(Hz) correspond to those of the machine (see the
data plate and the wiring diagram).
2 -Turn the on/off switch to 0 (OFF).
3 -Connect the power cord to the outlet
(A)
, as illus-
trated, according to the network mains.
4 -The earth wire (yellow and green) must be con-
nected to its earth terminal PE.
5 -Switch on the power supply using the on/off switch.
6 -Press the "Reset" button.
7 -When the "Start" button is pressed, the table
should rotate in a clockwise direction.