7
2.SPECIFICATION
2.1 Performance data of Swimming Pool Heat Pump Unit
*** REFRIGERANT : R32
PX30/32
7028290
30-6.7
23.7-5.46
7.22-0.42
100-175
30.00
40
13.46-6.28
7.28-4.65
220~240/1/ 50
Mitsubishi
R32
2
Horizontal
400-900
75*2
42-58
28-38
50
10.0
1.5
1.01
include
1165
×
470
×
1275
H*provided it is correctly insulated, calculation model : min vol 4x heating capacity (A15/W25)
max vol 7x heating capacity (A15/W25)
MODEL
kW
kW
kW
2
m
A
A
V/Ph/Hz
RPM
W
dB(A)
dB(A)
mm
3
m /h
kg
Ton
mm
Hydro-Pro Inverter
Part nr.
Heating capacity A27/W27 (max.-min.)
Heating capacity A15/W25 (max.-min.)
Power input (max.-min.)
Swimming pool volume*
Rated current
Minimum fuse
C.O.P. at A27/W27
C.O.P. at A15/W25
Power supply
Heat exchanger
Compressor brand
Refrigerant
Fan quantety
Fan direction
Fan speed
Power input of Fan
Noise level(1m)
Noise level(10m)
Water connection
Nominal flow rate
R32 Volume
CO2 equivalent
Wifi moudule
Net dimension
PX30T/32
7028291
30-6.7
23.7-5.46
7.35-0.42
100-175
12.50
20
13.46-6.28
7.28-4.65
380/3/ 50
Mitsubishi
R32
2
Horizontal
400-900
75*2
42-58
28-38
50
10.0
1.5
1.01
include
1165
×
470
×
1275
Twist-titanium tube in PVC
Summary of Contents for hydro-pro PX