1. The unit can only be repaired by qualified installer centre personnel or an authorised
dealer.
(
for Europe market
)
2. This appliance is not intended for use by persons (including children) with reduced physical
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
(
for Europe market
)
Children should be supervised to ensure that they do not play with the appliance.
3. Please make sure that the unit and power connection have good earthing, otherwise may
cause electrical shock.
4. If the supply cord is damaged, it must be replaced by the manufacturer or our service agent
or similarly qualified person in order to avoid a hazard.
5. Directive 2002/96/EC (WEEE):
The symbol depicting a crossed-out waste bin that is underneath the appliance indicates
that this product, at the end of its useful life, must be handled separately from domestic
waste, must be taken to a recycling centre for electric and electronic devices or handed
back to the dealer when purchasing an equivalent appliance.
6. Directive 2002/95/EC (RoHs): This product is compliant with directive 2002/95/EC (RoHs)
concerning restrictions for the use of harmful substances in electric and electronic devices.
7. The unit CANNOT be installed near the flammable gas. Once there is any leakage of the gas
, fire can be occur.
8. Make sure that there is circuit breaker for the unit, lack of circuit breaker can lead to
electrical shock or fire.
9. The heat pump located inside the unit is equipped with an over-load protection system. It
does not allow for the unit to start for at least 3 minutes from a previous stoppage.
10. The unit can only be repaired by the qualified personnel of an installer center or an
authorized dealer.
(
for North America market
)
11. Installation must be performed in accordance with the NEC/CEC by authorized person only.
(
for North America market
)
12. USE SUPPLY WIRES SUITABLE FOR 75
℃
.
13. Caution: Single wall heat exchanger, not suitable for potable water connection.
Caution & Warning
1. PREFACE
3
4
2.SPECIFICATION
2.1 Performance data of Swimming Pool Heat Pump Unit
*** REFRIGERANT : R32
PIV7/32
7028283
7.24-1.82
5.64-1.39
1.8-0.13
20-35
7.9
10
13.13-5.66
7.15-4.41
220~240/1/ 50
Mitsubishi
R32
1
Horizontal
400-700
40
38-50
19-29
50
2.4
0.35
0.24
include
1000
×
418
×
605
PIV11/32
7028284
11-2.23
7.9-1.58
2.05-0.15
30-53
9.0
12
13.24-5.84
7.22-4.67
220~240/1/ 50
Mitsubishi
R32
1
Horizontal
400-800
40
39-51
20-30
50
3.0
0.4
0.29
include
1000
×
418
×
605
PIV14/32
7028285
14-2.52
9.5-1.79
2.15-0.16
40-70
9.5
12
13.35-6.64
7.28-4.52
220~240/1/ 50
Mitsubishi
R32
1
Horizontal
400-800
40
42-53
22-32
50
4.9
0.5
0.32
include
1000
×
418
×
605
H*provided it is correctly insulated, calculation model : min vol 4x heating capacity (A15/W25)
max vol 7x heating capacity (A15/W25)
MODEL
kW
kW
kW
2
m
A
A
V/Ph/Hz
RPM
W
dB(A)
dB(A)
mm
3
m /h
kg
Ton
mm
Hydro-Pro Inverter
Part nr.
Heating capacity A27/W27 (max.-min.)
Heating capacity A15/W25 (max.-min.)
Power input (max.-min.)
Swimming pool volume*
Rated current
Minimum fuse
C.O.P. at A27/W27
C.O.P. at A15/W25
Power supply
Heat exchanger
Compressor brand
Refrigerant
Fan quantety
Fan direction
Fan speed
Power input of Fan
Noise level(1m)
Noise level(10m)
Water connection
Nominal flow rate
R32 Volume
CO2 equivalent
Wifi moudule
Net dimension
Twist-titanium tube in PVC
Summary of Contents for hydro-pro PX