  After  removing  the  packing  materials,  make  sure 

the contents are in good condition and complete in 

all parts. If you notice any damage or missing parts, 

contact the Dealer from whom you purchased the 

appliance.

  This appliance is designed for air dehumidification 

and it must be installed indoors.

  This  appliance  must  be  utilised  exclusively  for  its 

intended purpose. All other uses are construed as 

improper  and  potentially  dangerous.  The 

manufacturer cannot be held liable for any damage 

deriving  from  improper,  incorrect  or  unreasonable 

use of the appliance.

  The  appliances  are  supplied  without  grilles  or 

cabinet. Protective elements must be installed such 

as to prevent accidental contact with the appliance.

  This handbook must be kept safe because it is an 

integral  part  of  the  appliance  and  must  therefore 

ALWAYS accompany it, also when it is transferred 

to a new owner or user or when it is relocated for 

use  in  a  different  system.  If  the  handbook  is 

damaged  or  lost,  order  a  replacement  copy  from 

your local Technical Support Service.

  Repairs and maintenance work must be carried out 

by  the  Technical  Support  Service  or  by  qualified 

personnel in compliance with the prescriptions set 

down in this handbook.

  The  technical  dataplate  shows  the  technical  and 

performance data of the appliance. If the technical 

dataplate  is  lost  or  misplaced,  order  a  duplicate 

from  the  Technical  Support  Service.  Tampering 

with,  removal  of,  or  absence  of  the  Technical 

Dataplate  or  any  other  items,  such  that  prevents 

unequivocal  identification  of  the  appliance,  will 

hinder installation and maintenance procedures.

  In  the  case  of  faults  and/or  malfunctioning  of  the 

appliance, switch it off and do not attempt to repair 

it yourself. For repairs always contact the technical 

service centres authorized by the manufacturer and 

insist  on  the  use  of  genuine  original  replacement 

parts. Failure to comply with the above prescriptions 

will impact negatively on the safety of the appliance.

  Do  not  use  extension  cables  when  working  in 

bathrooms or shower areas except with the utmost 

caution. 

Do not install the appliance in rooms in which the air 

may be contaminated with gas, oil mist or sulphur or 

close to sources of heat

  If  you  decide  you  no  longer  wish  to  use  the 

appliance, make it inoperative by unplugging it from 

the mains supply and cutting off the power cable. 

Make  safe  all  parts  of  the  appliance  that  may 

constitute a source of danger, especially for children 

who may attempt to play with the appliance

Note that the use of electrically powered products calls for 

compliance with a series of basic safety rules:

 Do not place heavy or hot objects on the appliance.

 Do not allow children or unassisted differently abled 

persons to use the appliance.

 Do not touch the appliance if you have bare feet or 

when any parts of your body are wet.

 Do not attempt to service or clean the appliance until 

you have disconnected it from the mains supply and 

set the main electrical power breaker to “off”.

 Do  not  attempt  to  alter  safety  or  control  devices 

without the express authorisation and instructions of 

the manufacturer.

 Do not spray water directly onto the appliance.

 Do not pull, disconnect or twist the electrical cables 

connected to the appliance, even when the appliance 

is disconnected from the mains supply.

 Do  not  stand  on  the  appliance  and/or  place  any 

objects on it.

 Do  not  poke  pointed  instruments  through  the  air 

intake and outlet grilles.

 Do not open the covers providing access to internal 

parts of the appliance until you have set the main 

electrical power breaker to “off”.

 It is prohibited to disperse the packing materials in 

the  environment  or  leave  them  within  reach  of 

children. Discarded packing materials can constitute 

a source of danger.

SAFETY PRESCRIPTIONS

WARNINGS

2

Summary of Contents for VESTA 80 FVI

Page 1: ...VESTA 80 series Isothermal dehumidifiers VESTA 80 FVI Vertical version for exposed recessed VESTA 80 HI Horizontal ductable version INSTRUCTION OPERATING AND MAINTENANCE MANUAL MIU VE80I GB 002 05 17...

Page 2: ...s appear in this handbook Warning Prohibited I Installer U User A Technical Support Compliance and range 1 Precautions 2 Safety prescriptions 2 Appliance description 3 Identification 4 Technical data...

Page 3: ...magnetic compatibility Directive 2014 30 EU Standards Safety machinery electrical equipment of machines Part 1 General requirements EN 60204 1 2006 and rev EN 55014 1 2006 Electromagnetic compatibilit...

Page 4: ...d by the manufacturer and insist on the use of genuine original replacement parts Failure to comply with the above prescriptions will impact negatively on the safety of the appliance Do not use extens...

Page 5: ...minium fins a reciprocating compressor mounted on antivibration supports or springs VESTA 80V a capillary expansion tube and a filter dryer VESTA 80 delivers air at neutral temperature with respect to...

Page 6: ...porator con denser post treatment 9 Fan access panel 10 Compressor VESTA 80 HI horizontal ductable version Top view with internal layout of the main unit components Side view water and condensate drai...

Page 7: ...5x201x695 mm Frame WxDxH 750x230x740 mm Version VESTA 80 HI WxDxH mm Pre and post treatment coils hydraulic connections VESTA 80 FVI no 2 3 8 GAS female Version VESTA 80 HI no 2 1 2 GAS female Total s...

Page 8: ...essure of the fan The speed regulating system of the fan allows the balance of the pressure drop which is due to the different lengths of the ducts VESTA80I is equipped with refrigerating system with...

Page 9: ...I U A ELECTRICAL DIAGRAM REFRIGERANT CIRCUIT 7...

Page 10: ...struction handbook is an integral part of the appliance Please read it carefully and keep it safe Remove the packing material only when the unit has been moved to the point of installation It is prohi...

Page 11: ...y the system designer or a suitably skilled technician and must take account of technical requirements technical standards and compliance with statutory legislation VESTA 80 HI Horizontal ductable ver...

Page 12: ...the frame into the recess Clean the recess carefully before inserting the frame Before routing the various pipes into the dehumi difier installation recess fit the frame in such a way as to be able to...

Page 13: ...draulic pipes and electrical wiring Front panel Clearance 60 mm Attach the front panel as shown in the figure 11 25 mm 25 mm 30 mm 30 mm Side view panel panel Top view VESTA 80 FVI VESTA 80 FVII Diagr...

Page 14: ...technician and must take account of technical requirements technical standards and compliance with statuto ry legislation Check pressure drops of the air outlet intake gril les and any ducts in relat...

Page 15: ...t is perfectly level or slightly tilted in such a way as to facilitate the drainage of condensate through the metal manifold Suspended from ceiling side view The figure alongside shows two methods of...

Page 16: ...ompressor access panel 4 Removable cover 5 Electrical panel Mounted on beams The figure alongside shows installation of the appliance on a flat surface Choose antivibration mounts in compliance with t...

Page 17: ...ifold and siphon Condensate drain VESTA 80 dehumidifiers are equipped with a condensate collection tray to be connected to a drain hose that must be routed to a suitable drainage point VESTA 80 FVI VE...

Page 18: ...he electrical circuit diagrams Model Power supply V Ph Hz Max power consumption W Max current input W Delayed action line fuse A Power input con ductor cross section mm2 Earth conductor cross section...

Page 19: ...uit must be emptied or it must protected by adding antifreeze such as ethylene glycol in the amounts recommended by the antifreeze producer CHECKS DURING AND FOLLOWING COMMISSIONING PROLONGED DISUSE O...

Page 20: ...ore changing the fan speed DISCONNECT THE MAINS SUPPLY to the appliance 3 is Minimum speed for plastic and metal fan is Red 2 is Medium speed default for metal fan is Orange for Metal fan is Blue 1 is...

Page 21: ...hen water starts to flow from the appliance bleed valves close them and continue filling up to the pressure value specified for the system Check that the hydraulic unions are watertight This operation...

Page 22: ...Operation without the panels cor rectly fitted can lead to malfunctioning of the unit poor efficiency difficulty in draining condensate with consequent dripping water from the unit Before starting up...

Page 23: ...pplied with the room control panel you are using OPERATIONS POSSIBLE ON THE ROOM CONTROL PANEL Accessory Activation Set the main switch to On Set the required room humidity value by means of the regul...

Page 24: ...hat the VESTA 80 unit is effectively con nected to the electrical supply For all communications requests for technical service or replacement parts always quote mod el and serial number shown on the i...

Page 25: ...s are composed of a series of flashes having the following meaning If the VESTA 80 appliance is to be scrapped it must be disassembled and the parts sorted according to their construction material by...

Page 26: ...NOTES 24...

Page 27: ......

Page 28: ......

Reviews: