H - HOLE 7 mm.
E
Q
M
8TR1062/1
INSTRUCTIONS TUBÒ | ROBÒ CM186TR KIT WIRELESS
WITH START/STOP CENTRAL VACUUM UNIT
LINE: PERFETTO - PERFETTO INOX - CLASSIC - STUDIO – STUDIO TS - SILVER
WITH RECEIVER AND TRANSMITTER COMPLETE (SPARE)
INSTALLATION
CONNECTION
SUPPLIED COMPONENTS
2
-Remove the closure cap
(M)
of the power unit body, insert grommet
(Q)
in the
hole
(H)
and depression detection tube
(E)
REMARK
If there isn’t a hole (H)
for the depression detection hose (E) in the body of the
vacuum unit, you will have to drill a 7mm diameter hole.
3
-Connect plug line
(F)
to connector
(N)
of the central vacuum unit.
If the vacuum system has a low voltage line for some of the vacuum sockets, use plug
adaptor
(P)
to connect both inlet lines.
REMARK
If the vacuum system is started from the sockets circuit, it can’t be turned off with
the radio control.
S1
S2
A
B
T
V
E
C
V
T
T
R
R
D
1,5 meters
F
Q
P
R
F
1
-Position the receiver
(R)
near the central vacuum
unit at a distance of roughly 1.5 meters
Fix the receiver
(R)
to the wall with the screws and
dowels supplied
(V)
N
P
E
R
EN
T -
wireless transmitter with ROBÒ base
A -
start/stop button
B -
wireless signal LED
C -
battery
D -
transmitter fixing support with screw
E -
depression detection tube
F -
plug cable for 12V line activation
R -
appliance
Wireless receiver
V -
screws with plugs
P -
adapter with double plug
Q -
grommet
OPERATING FREQUENCY
433.92 Mhz
ACTUAL RADIO POWER
0.3mW
TYPE OF MODULATION
amplitude
(ON OFF)
ABSORPTION DURING
TRANSMISSION
10mA
COMPLIANCE WITH DIRECTIVE 99/05/EC
The remote control is compliant with the essential
requirements provided by Directive 99/05/EC.
The following Technical Standards have been applied:
EN 60335-1, EN 301489-3, EN 300220-3
ATTENTION
If a house has several floors,
we recommend installing the
receiver
(R)
on the middle floor.
The Receiver
(R)
cannot be
installed outside the house.
Inside a building, the operating
range between the receiver
(R)
and the transmitter
(T)
is 15m.
and it is capable of intersection
two floors
(S1 - S2)