background image

4

DANGER

WARNING

WARNING

NOTE

WARNING

Improper connection of the electrical outlet grounding 
conductor might result in a risk of electric shock. Check 
with a qualified electrician if you are uncertain whether 
or not the electrical outlet is properly grounded. Do not 
modify the plug provided with the product if it does 
not fit in the outlet. Have a proper outlet installed by a 
qualified electrician.
 .............................................................................................
Do NOT DROP charger or coupler.
 .............................................................................................

If the output cable becomes separated from the charger 
module or the charge coupler, DO NOT ATTEMPT TO 
REPAIR THE CABLE YOURSELF. Contact AV Customer 
Support for assistance.
 .............................................................................................

When using your charger, basic precautions should always 
be followed, including the following:

•  See warnings on charger cord label. Read warnings 

before operating the unit the first time. Read all 

instructions in this guide before using this product.

•  Never use the charger with an extension cord.
•  Shock hazard – make sure the plug is fully inserted 

into the wall outlet so that there are no exposed blade 

surfaces.

•  Children should be supervised when in the vicinity of 

the charger while plugged in.

•  Do not put fingers into the electric charge coupler.
•  To reduce the risk of fire, connect only to a circuit 

provided with 20 amps maximum branch circuit 

overcurrent protection.

•  Do not use in a commercial garage classified for 

internal combustion engine vehicles due to vapors of 
flammable liquids (gasoline) being present.

TurboCord will not charge and will give a fault indication if 
ground is not present

.

Summary of Contents for TurboCord

Page 1: ...USER GUIDE TURBOCORDTM PORTABLE CHARGER 120V 240V DUAL VOLTAGE AeroVironment EV Solutions...

Page 2: ...names No portion of these materials may be duplicated used or disclosed without prior written permission from AeroVironment Inc Disclaimer This user guide includes the latest information available at...

Page 3: ...er Support Write down the Serial Number of your charger in the Owner s Record above The Serial Number can be found on the bottom of the charger s plug in module AeroVironment EV Solutions Customer Sup...

Page 4: ...TurboCord Charger 3 TurboCord Charger Components 5 Required Outlets 6 SECTION 2 USING YOUR DUAL VOLTAGE CHARGER 7 Know Your Indicator Lights 8 Charging Your Vehicle 9 120 VAC Mode 9 240 VAC Mode 10 M...

Page 5: ...SECTION 1 INTRODUCTION...

Page 6: ...r death Indicates information about safety practices which if not followed could result in personal injury or are necessary to prevent fire or equipment overheating Indicates helpful information for i...

Page 7: ...turer specifically for use with this charger 120 VAC Operation the charger requires a 120 VAC single phase dedicated circuit It draws a maximum of 12 amp continuous current and requires a 15 amp rated...

Page 8: ...hould always be followed including the following See warnings on charger cord label Read warnings before operating the unit the first time Read all instructions in this guide before using this product...

Page 9: ...5 TURBOCORD CHARGER COMPONENTS Release button 240 V ADAPTER 240 V ADAPTER CLIP CHARGE MODULE CHARGE COUPLER...

Page 10: ...required NEMA 5 15R receptacle 120 V A dedicated 120 VAC single phase circuit and a 15 amp rated circuit breaker are required 208 240 VAC operation a NEMA 6 20R wall outlet is required NEMA 6 20R wal...

Page 11: ...SECTION 2 USING YOUR TURBOCORD CHARGER...

Page 12: ...cted an error If the RED TROUBLE Indicator is illuminated the charger will not deliver power to the vehicle The error must be corrected before a charging cycle can begin or continue Refer to the Troub...

Page 13: ...icle s charging outlet until it clicks If inserted properly the BLUE STATUS Indicator will blink once Once latched the CHARGE COUPLER will not disengage unless the release button is pressed manually 4...

Page 14: ...Plug the CHARGE COUPLER into your vehicle s charging receptacle until it clicks Once latched the CHARGE COUPLER will not disengage unless the release button is pressed manually 7 Automatic charge beg...

Page 15: ...nd safely stop BLUE STATUS Indicator remains ON solid A NOTE ON AUTO RESTART The Auto Restart feature helps ensure that your vehicle will be charged and ready for use when needed A charge may be inter...

Page 16: ...CHAPTER 3 TROUBLE SHOOTING...

Page 17: ...e charging begins or resumes Problem Possible Cause Solution BLUE STATUS Indicator does not illuminate No power to unit 1 Check circuit breaker and other circuit loads 2 Try another wall outlet 3 Ensu...

Page 18: ...tion persists contact AV Customer Support for assistance 2 Disconnect the charger and adapter if operating in 240 VAC mode from the wall outlet 3 Have a qualified electrician inspect the wall outlet a...

Page 19: ...APPENDIX...

Page 20: ...2 watts 4 watts Cable length approximately 20 ft 6 1 m Weight 4 lb 1 81 kg module 0 2 lb 0 09kg adapter Temperature operating 40 C to 50 C 40 F to 122 F Temperature storing and transporting 40 C to 70...

Page 21: ...location of your vehicle s charge receptacle Preferably mounted to a wall stud Dry wall and masonry wall installations require the use of appropriate inserts 2 Measure up approximately 36 from the flo...

Page 22: ...Support ALWAYS position the charger output cable so that it will not be driven over stepped on tripped over or otherwise damaged or stressed To prevent personal injury and damage to the charger ALWAY...

Page 23: ...d affect operation If you suspect your charger is receiving interference take the following steps before contacting Customer Support for service 1 Relocate nearby electrical appliances or equipment du...

Page 24: ...r Insulation The charger module adapter cable assembly and charge coupler are completely insulated no exposed live parts to protect against electric shock Unintentional Disconnection The charge couple...

Page 25: ...the original purchase price of the charger as applicable to a warranty claim b AV s liability under this warranty shall be limited to the repair or replacement at AV s option of defective component pa...

Page 26: ...ic shock 3 4 19 20 environmental rating 16 F features 3 19 G GFCI 11 20 H hanger 17 18 I indicator light 8 9 10 insulated 20 M manual stop 11 O outlet 3 4 6 8 9 10 11 13 14 output ground 20 P pilot si...

Page 27: ......

Page 28: ...Support 1 888 833 2148 evscs avinc com Corporate Headquarters AeroVironment Inc EV Solutions 181 W Huntington Drive Suite 202 Monrovia CA 91016 Corporate phone 626 357 9983 or 888 833 2148 ev avinc co...

Reviews: