pag.
44 di 64
Use and Maintenance Manual
M
MCCHH88--1111//EEM
M -- M
MCCHH1133--1166//EETT
Standard
Cap.7 _ Maintenance
Checking and cleaning
Change
SCHEDULED MAINTENANCE TABLE
7.4
TROUBLESHOOTING
7.5
Problem
Cause
Solution
The electric motor does not start Phase missing
Check fuses or condenser
Rotation speed and flow rate
Motor power too low
Check the motor and the line
decrease
The belt slips
Restore proper belt tension
The flow rate diminishes
Valves not working
Contact technical assistance
without rpm decreasing
4 th stage piston worn
Contact technical assistance
Fittings loose / leaking seals
Check for leaks with soapy
water and eliminate them
Intake filter clogged
Replace filter
Intake extension kinked
Straighten, use stiffer pipe
Piston or piston rings worn
Contact technical assistance
Air smells of oil
Filter cartridge exhausted
Replace
Piston rings worn
Contact technical assistance
Compressor overheats
Direction of rotation wrong
Check direction of rotation
Cooling tubes dirty
Contact technical assistance
Incomplete valve closure
Contact technical assistance
(causing overload of another stage)
5
10
30
40
50
250
500 1000 2000 3000 4000
Maintenance
hours hours hours hours hours hours hours hours hours hours hours
Condensate discharge
Automatic shutdown check
Lubricating oil level check
Main functions check
Clean condensate discharge valves
Condensate discharge O-rings
Condensate discharge valves
Belt wear and tension
Clean separator filter element
Oil change
1
st
, 2
nd
, 3
rd
-stage valves
HP water/oil separator
HP filter body
1
st
, 2
nd
, 3
rd
-stage segments
Check and replace HP flex hoses
Fitting/hose leak
General check-up
Pumping unit, general overhaul
1
st
and 2
nd
stage safety valves
Safety valves