background image

 

7

Air Brad Nailer F50RC     

      www.aeroprotools.com 

 

OPERATING INSTRUCTIONS 

4.1 Preparing a tool for first time operation 

Please Read and observe these Operating Instruction before using the tool. Basic safety measures should 

always  be  strictly  followed  to  protect  against  damage  to  the  equipment  and  personal  injury  to  the  user  or 

other people working in the vicinity of operation. 

 

4.2 Connection to the compressed air system 

Ensure that the pressure supplied by the compressed air system does not exceed the maximum allowable 

pressure  of  the  fastener  driving  tool.  Set  the  air  pressure  initially  to  the  lower  value  of  the  recommended 

allowable pressure (see

 

TECHNICAL DATA). 

Empty  the  magazine  to  prevent  a  fastener  from  being  ejected  at  the  next  stage  of  work  in  the  event  that 

internal parts of the fastener driving tool are not in the starting position following maintenance and repair work 

or transportation. 

Connect the fastener driving tool to the compressed air supply using suitable pressure hose equipped with 

quick-action connectors. 

Check for proper functioning by applying the muzzle of the fastener driving tool to a piece of wood or wooden 

material and actuating the trigger once or twice. 

4.3Filling the magazine 

 

Only those fasteners specified under TECHNICAL DATA (see 1.1) may be used 

When filling the magazine, hold the tool so that the muzzle is not pointing towards the operator or any other 

person or animals. 

4.4 Handling the tool 

 

Pay attention to 

2-Special Reference-

of these operating instructions. 

Having  checked  that  the  fastener  driving  tool  is  functioning  correctly,  apply  the  tool  to  a  work  piece  and 

actuate the trigger. 

Check whether the fastener has been driven into the work piece in accordance with the requirements. 

- if the fastener is protruding, increase the air pressure in increments of 0.5 bar, checking the result 

after each new adjustment; 

- if the fastener is driven into an excessive depth reduce the air pressure I increments of 0.5 bar until 

the result is satisfactory. 

You  should  endeavor  in  any  event  to  work  with  the  lowest  possible  air  pressure.  This  will  give  you  three 

significant advantages; 

          1.energy will be saved, 

          2.less noise will be produced, 

          3.a reduction in fastener driving tool wear will be achieved. 

Avoid triggering the fastener driving tool if the magazine is empty. 

Any  defective  or  improperly  functioning  fastener  driving  tool  must  immediately  be  disconnected  from  the 

compressed air supply and passed to a specialist for inspection. 

In  the  event  of  longer  breaks  in  work  or  at  the  end  of  the  working  shift,  disconnect  the  tool  from  the 

compressed air supply and it is recommended to empty the magazine. 

The  compressed  air  connectors  of  the  fastener  driving  tool  and  the  hoses  should  be  protected  against 

contamination,  the  ingress  of  coarse  dust  chips,  sand  etc,  will  result  in  leaks  and  damage  to  the  fastener 

driving tool and the couplings. 

Summary of Contents for F50RC

Page 1: ...o lungs if an effective dust mask is not worn Damage to hearing if effective hearing protection is not worn Health defects resulting from vibration emission if the power tool is being used over longer period of time or not adequately managed and properly maintained Wear eye protection 2014 OPERATING INSTRUCTIONS FOR FASTENER DRIVING TOOLS OPERATED BY COMPRESSED AIR IMPORTANT Read all safety rules ...

Page 2: ... protecting personal safety and preventing equipment problems it is very important to read this manual carefully and understand it thoroughly before using the product the symbols listed below are used to indicate this information DANGER Potential hazard that will result in serious injury or loss of life WARRNING Potential hazard that could result in serious injury or loss of life CAUTION Potential...

Page 3: ... switch or safety valve for any reason They have been preset at the factory for this compressor s maximum pressure Tampering with the pressure switch or the safety valve may cause personal injury or property damage Risk of burns The pump and the manifold generate high temperatures In order to avoid burns or other injuries do not touch the pump the manifold or the transfer tube while the compressor...

Page 4: ... parts Do not use the tool near or below freezing temperatures as doing so may cause tool failure Do not store the tool in a freezing environment to prevent ice formation on the operating valves of the tool as doing so may cause tool failure Handling and storage of oil Use with adequate ventilation Avoid contact of oil with eyes skin and clothing Avoid breathing spray or mist Store in a tightly cl...

Page 5: ... specifically designed for professional work Air system Always use clean dry regulated compressed air at 4 8 to 7 5 bar 70 to 110psi Do not exceed the maximum or minimum pressures Operating the tool at the wrong pressure too low or too high will cause excessive noise or rapid wear of tool WARNING Potential hazard that could result in serious injury or loss of life Keep hands and other parts of the...

Page 6: ...ury or loss of life Do not use the tool if it is not in proper working order Do not use oxygen carbon dioxide or any other combustible or bottled gas to power this tool Do not use this tool in the presence of any flammable liquids or gases Keep hands and other parts of the body away from the firing head during use Do not point the tool towards the operator or other people Never attempt to clear a ...

Page 7: ... the muzzle is not pointing towards the operator or any other person or animals 4 4 Handling the tool Pay attention to 2 Special Reference of these operating instructions Having checked that the fastener driving tool is functioning correctly apply the tool to a work piece and actuate the trigger Check whether the fastener has been driven into the work piece in accordance with the requirements if t...

Page 8: ...gular lubrication if your tool without using the in liner automatic oilier place 2 or 6 drops of pneumatic tool oil into the air inlet before each work day or after 2 hours of continuous use depending in the characteristic of workpiece or type of fasteners Air operated tools must be inspected periodically and worn or broken parts must be replaced to keep the tool operating safely and efficiently C...

Page 9: ... 1 Tighten screws 2 Check and replace O rings or bumper Air leak between body and cylinder cap 1 Loose screws 2 Worn or damaged O rings or seals 1 Tighten screw 2 Check and replace O rings or bumper Blade driving fastener too deep 1 Worn bumper 2 Air pressure is too high 1 Replace bumper 2 Adjust the air pressure Tool does not operate well can not drive fastener or operate sluggishly 1 Inadequate ...

Page 10: ...10 Air Brad Nailer F50RC www aeroprotools com If any parts are missing or damaged or if you have any questions please contact to rongpeng company ...

Reviews: