Aeropro F50RC Operating Instructions Manual Download Page 4

 

4

Air Brad Nailer F50RC     

      www.aeroprotools.com 

 

Do not carry the compressor while it is running. 

Do not operate the compressor if it is not in a stable position. 

Do not operate the compressor on a rooftop or in an elevated position that could allow the unit to fall or be tipped 

over. 

Always replace a damaged gauge before operating the unit again. 

 

 

CAUTION! 

Potential hazard that may result in moderate injury or damage to equipment. 

Always ensure that the tool has stopped before connecting to the air supply. 

Do not wear watches, rings, bracelets, or loose clothing when using any air tool. 

Do not overload the tool. Allow the tool to operate at its optimum speed for maximum efficiency. 

Do not use a tool that is leaking air, with missing or damaged parts, or that requires repairs.Verify that all screws are 

securely tightened. 

For optimal safety and tool performance, inspect the tool daily in order to ensure free movement of the trigger, safety 

mechanisms, and springs. 

Always keep your air tools clean and lubricated. Daily lubrication is essential to avoid internal corrosion and possible 

failures. 

Ensure the floor is not slippery and wear non-slip shoes. Floors should be kept clean can clear. 

Always follow all workshop safety rules, regulations, and conditions when using the tools. 

Carry the tool by the handle only. Do not carry the tools with a finger on the trigger. Do not carry the tool by the hose, 

magazine or any other parts. 

Do not use the tool near or below freezing temperatures, as doing so may cause tool failure. 

Do not store the tool in a freezing environment to prevent ice formation on the operating valves of the tool, as doing 

so may cause tool failure. 

Handling and storage of oil: Use with adequate ventilation. Avoid contact of oil with eyes, skin, and clothing.  Avoid 

breathing spray or mist. Store in a tightly closed container in a cool, dry, well-ventilated area free from incompatible 

substances. 

CAUTION! 

Potential hazard that may result in moderate injury or damage to equipment. 

Disconnect  tool  from  the  air  supply  and  turn  off  the  compressor  before  performing  any 

maintenance, or changing accessories, when the tool is not in use, when it is being handed to 

another person, and when it is left unattended. Failure to comply may result in moderate injury or 

damage to equipment. 

 

Use safety goggles and ear protection: 

Wear safety glasses with side shields when operating the tool/compressor and verify that others in 

the  work  area  are  also  wearing  safety  glasses.  Safety  glasses  must  conform  to 

American 

national standards institute (ANSIZ87.1)

 

Requirements and must provide protection from flying particles from the front and the sides.   

Air powered tools are loud and the sound can cause hearing damage. Always wear ear protection 

to prevent hearing damage and loss. Failure to comply may result in moderate injury. 

NOTE: Recycle unwanted materials father than disposing of them as waste. Sort the tools, hoses, and package into 

specific categories and take to the local recycling centre or dispose of them in an environmentally safe way. 

 

Summary of Contents for F50RC

Page 1: ...o lungs if an effective dust mask is not worn Damage to hearing if effective hearing protection is not worn Health defects resulting from vibration emission if the power tool is being used over longer period of time or not adequately managed and properly maintained Wear eye protection 2014 OPERATING INSTRUCTIONS FOR FASTENER DRIVING TOOLS OPERATED BY COMPRESSED AIR IMPORTANT Read all safety rules ...

Page 2: ... protecting personal safety and preventing equipment problems it is very important to read this manual carefully and understand it thoroughly before using the product the symbols listed below are used to indicate this information DANGER Potential hazard that will result in serious injury or loss of life WARRNING Potential hazard that could result in serious injury or loss of life CAUTION Potential...

Page 3: ... switch or safety valve for any reason They have been preset at the factory for this compressor s maximum pressure Tampering with the pressure switch or the safety valve may cause personal injury or property damage Risk of burns The pump and the manifold generate high temperatures In order to avoid burns or other injuries do not touch the pump the manifold or the transfer tube while the compressor...

Page 4: ... parts Do not use the tool near or below freezing temperatures as doing so may cause tool failure Do not store the tool in a freezing environment to prevent ice formation on the operating valves of the tool as doing so may cause tool failure Handling and storage of oil Use with adequate ventilation Avoid contact of oil with eyes skin and clothing Avoid breathing spray or mist Store in a tightly cl...

Page 5: ... specifically designed for professional work Air system Always use clean dry regulated compressed air at 4 8 to 7 5 bar 70 to 110psi Do not exceed the maximum or minimum pressures Operating the tool at the wrong pressure too low or too high will cause excessive noise or rapid wear of tool WARNING Potential hazard that could result in serious injury or loss of life Keep hands and other parts of the...

Page 6: ...ury or loss of life Do not use the tool if it is not in proper working order Do not use oxygen carbon dioxide or any other combustible or bottled gas to power this tool Do not use this tool in the presence of any flammable liquids or gases Keep hands and other parts of the body away from the firing head during use Do not point the tool towards the operator or other people Never attempt to clear a ...

Page 7: ... the muzzle is not pointing towards the operator or any other person or animals 4 4 Handling the tool Pay attention to 2 Special Reference of these operating instructions Having checked that the fastener driving tool is functioning correctly apply the tool to a work piece and actuate the trigger Check whether the fastener has been driven into the work piece in accordance with the requirements if t...

Page 8: ...gular lubrication if your tool without using the in liner automatic oilier place 2 or 6 drops of pneumatic tool oil into the air inlet before each work day or after 2 hours of continuous use depending in the characteristic of workpiece or type of fasteners Air operated tools must be inspected periodically and worn or broken parts must be replaced to keep the tool operating safely and efficiently C...

Page 9: ... 1 Tighten screws 2 Check and replace O rings or bumper Air leak between body and cylinder cap 1 Loose screws 2 Worn or damaged O rings or seals 1 Tighten screw 2 Check and replace O rings or bumper Blade driving fastener too deep 1 Worn bumper 2 Air pressure is too high 1 Replace bumper 2 Adjust the air pressure Tool does not operate well can not drive fastener or operate sluggishly 1 Inadequate ...

Page 10: ...10 Air Brad Nailer F50RC www aeroprotools com If any parts are missing or damaged or if you have any questions please contact to rongpeng company ...

Reviews: