background image

1. Power on the AP

 

and allow it to find and connect to HiveManager Classic. Once the

AP

 

is

 

connected, it appears in the table of unconfigured devices on the 

Monitor > Devices

page and is categorized as New under the Management Status table header.

2. Select the check box for the AP, and then choose 

Update > Advanced >

 

Update Country

.

3. On the 

Update Country Code

 page, choose the appropriate country code from the drop-

down list, and then click 

Upload

.

For Devices Running HiveManager NG

1. Power on the AP and allow it to find and connect to HiveManager NG. Once the AP

 

is

connected it appears in the table of devices on the 

Monitor > Devices

 page.

2. Select the check box next to the AP, and then choose 

Assign Country Code

 from the 

Actions

drop-down list. In the dialog box that appears, select the appropriate country from the drop-
down list, and then click 

Save

.

3. Upload your changes to the device.

Safety Guidelines

The information in this section applies to AP150W devices.

The following safety icons are used in these guidelines to identify the type of precaution:

This icon indicates a general caution. Failure to comply with a caution 

notification can result in damage to equipment.

This icon indicates an electrical caution. Failure to comply with an electrical 

notification can result in serious injury or death, and extensive damage to 
equipment.

The following table lists the safety precautions you should follow when installing your 

AP150W devices.

Aerohive devices must be installed by a professional installer who is certified to 

install these types of devices and to ensure that they are properly grounded 
and meet applicable local and national electrical codes.

These devices are intended for indoor use only.

Do not install the device in an environment where the operating ambient 

temperature might exceed the recommended ranges.

Electrical equipment generates heat. Ambient air temperature may not be 

adequate to cool equipment to acceptable operating temperatures without 

adequate circulation. Be sure that the room where you install your device has 

adequate air circulation.

Changes or modifications made to this device that are not expressly approved 

by the party responsible for compliance could void the user's authority to 

operate the equipment.

Page 2 of 17

AP150W Hardware User Guide

8/21/2017

Preliminarty 

Draft

Summary of Contents for AP150W

Page 1: ...of the device allows you to connect the AP150W without disabling the other cable or connector The AP150W has the power to support enterprise grade features including built in application visibility and control RADIUS authentication DHCP captive web portals location services and spectrum analysis For more information about Aerohive APs in general see Introduction to Aerohive APs For information abo...

Page 2: ...ndicates a general caution Failure to comply with a caution notification can result in damage to equipment This icon indicates an electrical caution Failure to comply with an electrical notification can result in serious injury or death and extensive damage to equipment The following table lists the safety precautions you should follow when installing your AP150W devices Aerohive devices must be i...

Page 3: ...pliance is located Install the AP150W The following sections describe how to install your AP150W devices connect them to the network and start managing them in HiveManager NG Shipping Carton Contents The AP150W access point shipping carton contains the following items AP150W chassis Generic QuickStart Card Wall mounting bracket and mounting hardware packet containing four Phillips screws and one T...

Page 4: ...with the large opening in the bracket aligned to the hole in the wall Use at least two mounting screws to mount the bracket The illustration below shows a bracket for a US SINGLE wall socket Page 4 of 17 AP150W Hardware User Guide 8 21 2017 P r e l i m i n a r t y D r a f t ...

Page 5: ... use the short Ethernet cable that ships with the device to connect the Eth0 port on the back of your device to the jack in the wall Page 5 of 17 AP150W Hardware User Guide 8 21 2017 P r e l i m i n a r t y D r a f t ...

Page 6: ...nd the flange on top of the bracket onto the opening at the top of the device back panel Push down on the device to seat it on the bracket as shown in the illustration The device will rest on the two flanges at the bottom of the bracket Page 6 of 17 AP150W Hardware User Guide 8 21 2017 P r e l i m i n a r t y D r a f t ...

Page 7: ...5 Install a screw in the top of the device to secure the unit to the top flange on the bracket Page 7 of 17 AP150W Hardware User Guide 8 21 2017 P r e l i m i n a r t y D r a f t ...

Page 8: ...hernet cable from ETH0 on the AP to a switch that provides PoE power or use a PoE injector see Ethernet Ports 2 After the AP receives power it automatically tries to get network settings and contact HiveManager NG This process takes about five minutes When you see the AP listed on the Page 8 of 17 AP150W Hardware User Guide 8 21 2017 P r e l i m i n a r t y D r a f t ...

Page 9: ...ate the following states of activity Dark There is no power or the status indicator is disabled Amber flashing This is an alert that indicates that the device is performing a firmware upgrade Do not power off the device during this process Amber steady This is an alert that indicates that the CAPWAP connection has not been successfully established or the device is booting or shutting down Green Th...

Page 10: ...tosensing 10 100 1000 Base T Ethernet Ports Two RJ45 passive pass thru ports on the back of the device RJ45 Console Port Power Options The AP150W can receive 802 3af and 802 3at PoE and PoE power through the Eth0 and Eth1 ports With 802 3af there is no PoE budget support on the downlink port With 802 3af the PoE budget on the downlink port is 12 W The AP150W can also be powered using a 48VDC 0 75 ...

Page 11: ...1000 Base T Ethernet PoE Output Port Eth2 Eth3 2x Autosensing 10 100 1000 Base T Ethernet Port Passive PASS THRU connection Two RJ45 ports from the back of the AP to the bottom Built in BLE and Zigbee future use RJ45 Console Port AC power input connector 48 VDC 0 75 A power supply sold separately Power Specifications IEEE 802 3af PoE input Typical 11 3 W maximum 12 4 W IEEE 802 3at PoE input Typic...

Page 12: ...mpleted in the instructions accompanying the radio equipment 2 Pursuant to Article 10 10 of Directive 2014 53 EU the Commission may adopt implementing acts specifying how to present the information provided for in Article 10 10 3 Those implementing acts shall be adopted in accordance with the advisory procedure referred to in Article 45 2 of Directive 2014 53 EU 4 The measures set out in this Regu...

Page 13: ...s in conformity with this Regulation shall be deemed to be in conformity with Article 10 10 of Directive 2014 53 EU This Regulation shall be binding in its entirety and directly applicable in all Member States Done at Brussels For the Commission The President Jean Claude Juncker EU Declaration of Conformity This device complies with the essential requirements of the R TTE Directive 1999 5 EC The f...

Page 14: ...requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999 5 CE Ελληνική Greek ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Aerohive ΔΗΛΩΝΕΙ ΟΤΙ AP150W ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 1999 5 ΕΚ Français French Par la présente Aerohive déclare que l appareil AP150W est conforme aux exigences essentielles et aux autres disposition...

Page 15: ...pment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio or TV technician for help FCC Caution Any ...

Page 16: ... une utilisation à l intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux Radiation Exposure Statement This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20 cm between the radiator and people or animals Déc...

Page 17: ...秭赫頻帶內操作之無線資訊傳輸設備 限於室內使用 無線資訊傳設備的製造廠商應確保頻率穩定性 如依製造廠商使用手冊上所述正常操作 發射的信號應維持 於操作頻帶中 Taiwan MPE Warning 電磁波曝露量MPE標準值1 mW cm2 送測產品實值為0 75289 mW cm2 本產品使用時建議應距離人體 20cm Aerohive Documentation Portal Aerohive Blogs HiveCare Community Forum Copyright 2017 Aerohive Networks Inc Page 17 of 17 AP150W Hardware User Guide 8 21 2017 file C Users dknodel AppData Local Temp MC_ htm P r e l i m i n a r t y D r a f t ...

Reviews: