Installation Kit 

 

Three (3) standard installation kits as follows: 
 

Item 

Description 

Qty 

Part # 

Installation Kit, 6”, with large chip strainer 

099AIK-0002 

1(a) 

Suction hose 6” 

5ft 

099MPH-0006 

1(b) 

Hose clamp 6” 

099MHH-0005 

1(c) 

Machine adaptor 6” 

099AMS-0006 

1(d) 

Chip strainer, 6.5” x 8” x 3¼” 

099ACS-0004 

1(d) 

Optional chip deflector  

099ACD-0004 

 

 

 

 

Installation Kit, 8” 

099AIK-0003 

2(a) 

Suction hose 8” 

5ft 

099MPH-0008 

2(b) 

Hose clamp 8” 

099MHH-0006 

2(c) 

Machine adaptor 8” 

099AMS-0008 

2(d) 

Chip strainer, 8” x 10” x 4” 

099ACS-0005 

2(d) 

Optional chip deflector  

099ACD-0005 

 

Oil Drain Hose Kit 

 

Item 

Description 

Qty 

Part # 

Drain Hose Kit, c/w 

099MPH-0013 

1(a) 

Oil drain hose 

10ft 

099MPH-0004 

1(b) 

Oil drain bracket 

A99SPM-0002 

1(c) 

Nipple 

099MPB-0001 

1(d) 

Hose clamp 

099MHH-0002 

 
Installation:

 

 

Loop in oil drain hose is required  
to create air lock. 
Fill with water, coolant or oil. 
 
Failure to install correctly will  
result in no oil draining  

 

 

 

 

 

 

Summary of Contents for ARO-400

Page 1: ... 20 www aeroex com orderdesk aeroex com Aeroex Technologies Inc Oil Mist Collector Model ARO 400 600 Multi Stage Installation Service Manual www aeroex com 705 734 0199 sales aeroex com orderdesk aeroex com ...

Page 2: ...of Contents Specifications 3 Installation instructions 4 Installation Kit 5 Oil drain hose Kit 5 Electrical Connection 6 Direction of rotation 6 Wiring Connection 7 Maintenance 8 Filter options Coolant 9 Filter options Oil 10 Dimensions 11 Warranty 12 ...

Page 3: ...r For Oil the primary separation pack consists of a 1st stage ME and 2nd and 3rd stage multi layer fiber bed filter Final filtration 4th stage HEPA filter Specifications Model CFM Sound dB A Machine Tool Enclosure Volume ft Motor hp Voltage RPM Amps RPM ARO 400 6 inlet 350 500 68 125 1 0 External Motor 230 3 60 460 3 60 575 3 60 3 2 1 3 1 2 3450 ARO 600 6 inlet 600 700 70 200 1 0 External Motor 23...

Page 4: ...ting or flexible hose can be used Do not locate suction intake on machining applications in direct line of the cutting spray Install chip strainer See details next page Connect the oil drain line using loop in hose or pee trap Loop in hose must be minimum 8 below mist collector no max See instructions page 5 Fill loop with water or oil to create air lock Install motor starter and set overloads Con...

Page 5: ... Installation Kit 8 1 099AIK 0003 2 a Suction hose 8 5ft 099MPH 0008 2 b Hose clamp 8 1 099MHH 0006 2 c Machine adaptor 8 1 099AMS 0008 2 d Chip strainer 8 x 10 x 4 1 099ACS 0005 2 d Optional chip deflector 1 099ACD 0005 Oil Drain Hose Kit Item Description Qty Part 1 Drain Hose Kit c w 1 099MPH 0013 1 a Oil drain hose 10ft 099MPH 0004 1 b Oil drain bracket 1 A99SPM 0002 1 c Nipple 1 099MPB 0001 1 ...

Page 6: ...e control with 24 VDC signal Fused disconnect switch overloads pilot light 2 VFD Motor Starter Panel Fused disconnect switch start stop overloads pilot light 5 VFD Motor Starter NEMA 4X enclosure 3 Motor Starter Panel Fused disconnect switch start stop overloads pilot light Mount the motor starter control panel in a convenient location Machine mounted mist collectors can be wired into the CNC elec...

Page 7: ...7 01 20 www aeroex com orderdesk aeroex com Wiring Connection External Motor Wiring Diagram ...

Page 8: ... the maintenance interval The mist collector has one magnehelic gauge measuring the pressure drop on 4th stage HEPA filter Should the gauge reduce to near zero this indicates no air flow going to HEPA filter check filter stages 1 to 3 and chip strainer HEPA filter replacement Replace when magnehelic pressure gauge reaches the red zone Note If filter stages 1 3 or chip strainer are plugged no air f...

Page 9: ...cription Part Number 1 1st stage ME Mechanical Element A06FMS 0001 2 2nd stage AF Coolant Filter A06FAF 0001 3 3rd stage CM Coolant Mist Filter A06FCM 0004 4 4th stage HF HEPA Filter 95 0 3 microns 600HF 2095 4 4th stage HF HEPA Filter HEPA 99 97 0 3 microns Optional 600HF 2099 4 4th stage HF Odor Rid HEPA Filter Optional 600HF 3095 ...

Page 10: ...t Number 1 1st stage ME Mechanical Element A06FMS 0001 2 2nd stage OM 5 Oil Mist Fibre Bed Filter A06FOM 0005 3 3rd stage OM 7 Oil Mist Fibre Bed Filter A06FOM 0007 4 4th stage HF HEPA Filter 95 0 3 microns 600HF 2095 4 4th stage HF HEPA Filter HEPA 99 97 0 3 microns Optional 600HF 2099 4 4th stage HF Odor Rid HEPA Filter Optional 600HF 3095 ...

Page 11: ...11 01 20 www aeroex com orderdesk aeroex com Dimensions ...

Page 12: ...r and tear erosion or corrosion misuse abuse or improper handling by the purchaser or any third party Aeroex Technologies makes no additional warranties expressed or implied whether of merchantability or otherwise other than stated above AEROEX shall not be responsible for any indirect special or consequential damages nor for any other claim arising out of the sale rental or use of its equipment A...

Reviews: