NOTE: THIS FAN MUST BE INSTALLED BY A LICENSED AND QUALIFIED 

 

ELECTRICIAN IN ACCORDANCE WITH LOCAL AUTHORITY REGULATIONS 

13

1. 

Any  damage  incurred  after  delivery  to  the  owner  that  is  not  caused  by  a  fault  in  the  products  materials  or 

workmanship; damage from lightning or power surges; incorrect installation; damage due to incorrect installation; 

noise or other influence of ripple control or information access systems operated over power delivery infrastructure; 

water damage of any kind; installation or use outdoors; damage arising from connection to or use with alternative 

power systems (e.g. inverters, solar, etc.).

2. 

Interference from other devices operating on the same frequency. This issue can be overcome by 

reprogramming the remote control hand piece to the Fan. A mechanism to isolate power is required, this will 

remove the requirement to engage a licensed electrician to complete the programming steps.

3. 

Ceiling fans not installed by a licensed and qualified electrician in accordance with local authority regulations.

4. 

Incorrect operation of the ceiling fan, accidental damage, modification in any way or not servicing in accordance 

with the maintenance instructions.

5. 

Travelling costs incurred by AeroDC personnel or service agents exceeding 30kms between the nearest agents’ 

service depot and the customer. These costs must be met by the purchaser. 

6. 

Subject  to  any  statutory  provisions  to  the  contrary,  claims  for  damage  to  furniture,  carpet,  walls,  ceilings, 

foundations or any other consequential loss either directly or indirectly resulting from a faulty ceiling fan.

7. 

Signals sent through the mains power supply by the electricity supplier for off peak hot water, and other signals 

including those for street lights and such. These signals may cause an intermittent humming in the ceiling fan. It 

is not the fault of the ceiling fan.

8. 

When humidity is high and temperature drops moisture condenses on metal surfaces including ceiling fans. The 

layer of moisture can be almost microscopic but it will affect the surface by depositing a tiny layer of dissolved 

salts or airborne acidic compounds and thus eventually leading to corrosion if the product is not properly and 

regularly cleaned.

9. 

A service call fee will be charged where; there is nothing wrong with the ceiling fan or; the defective operation of 

the ceiling fan is due to failure of electricity or; the installation is not in accordance with AeroDC instructions and/

or applicable local regulations or; the defects have been caused by incorrect application or abuse of the ceiling fan 

or; the damage has been caused by unauthorised persons attempting to repair the fan

NOT COVERED BY WARRANTY.

DOCUMENTS TO RETAIN FOR FUTURE WARRANTY CLAIMS

TO ASSIST WITH ANY WARRANTY CLAIMS ATTACH THE FOLLOWING DOCUMENTS FOR  

FUTURE REFERENCE.

1. 

Copy of the Purchasing Receipt. 

2. 

Proof of Professional Installation - in-accordance with local authority Regulations (copy of installation Invoice, 

Safety Certificate or letter on Letter head including licence details) 

Summary of Contents for Profile DC

Page 1: ...AN FROM THE CEILING UNLESS INSTRUCTED TO DO SO National Warranty Number 1300 116 305 Monday to Friday 9am to 5pm AEST g NOTE THIS FAN MUST BE INSTALLED BY A LICENSED AND QUALIFIED ELECTRICIAN IN ACCORDANCE WITH LOCAL AUTHORITY REGULATIONS Australian Edition Version 2 5 October 2020 Installation User Manual PLEASE NOTE THE REMOTE CONTROL COMES PRE PROGRAMMED TO THE FAN ...

Page 2: ...m to allow for programming and ongoing maintenance 8 The Fan and Light if supplied must be earthed 9 Your warranty will be void if a solid state dimmer or any other brand of wall or remote controller is used 10 Installation using steel beams grid ceilings and flexible structures are not recommended due to their inability to absorb vibration from normal operation Timber is the recommended material ...

Page 3: ...ber frame is to be added it must be securely nailed or screwed between two beams After the fan is completely installed check to make sure that all connections are secure to prevent the fan from falling and or causing damage or injury To reduce the risk of personal injury do not bend or damage the motor or Fan Assembly when handling or during installation Please ensure special care is taken when as...

Page 4: ...istance To reduce the chance of marks or possible damage please only remove the parts when required for installation To avoid possible electrical shock be sure electricity is turned off at the main fuse box before assembling and wiring the fan WARNING Part Quantity Part Quantity Ceiling Bracket 1 Fan Motor 1 Ceiling Bracket Screws 2 ABS Blades 3 Ceiling Bracket Covers 2 Blade Screws 9 Receiver 1 B...

Page 5: ...ance of marks or possible damage please only remove the parts when required for installation To avoid possible electrical shock be sure electricity is turned off at the main fuse box before assembling and wiring the fan WARNING Handset Ceiling Bracket Ceiling Bracket Screws Fan Receiver Blades Blade Screws LED Light Kit Fan Motor Ceiling Bracket Screw cover Part Quantity Part Quantity Ceiling Brac...

Page 6: ...ower box or disconnect power by removing fuse or turning off circuit breaker This fan must be installed by a licensed and qualified electrician in accordance with local authority regulations INSTALLING FAN WITHOUT LIGHT In accordance with Australian Standards the fan blades must be at least 2 1 metres above floor level and the blades require at least 300mm clearance to the nearest object 1 3 2 4 5...

Page 7: ... power by removing fuse or turning off circuit breaker This fan must be installed by a licensed and qualified electrician in accordance with local authority regulations INSTALLING FAN WITHOUT LIGHT In accordance with Australian Standards the fan blades must be at least 2 1 metres above floor level and the blades require at least 300mm clearance to the nearest object 7 9 8 10 ...

Page 8: ...power box or disconnect power by removing fuse or turning off circuit breaker This fan must be installed by a licensed and qualified electrician in accordance with local authority regulations INSTALLING FAN WITH LIGHT In accordance with Australian Standards the fan blades must be at least 2 1 metres above floor level and the blades require at least 300mm clearance to the nearest object 1 3 2 4 5 6...

Page 9: ...t power by removing fuse or turning off circuit breaker This fan must be installed by a licensed and qualified electrician in accordance with local authority regulations INSTALLING FAN WITH LIGHT In accordance with Australian Standards the fan blades must be at least 2 1 metres above floor level and the blades require at least 300mm clearance to the nearest object 7 9 8 10 ...

Page 10: ...me remote can control multiple fans To remove a second remote see page 15 Removing a second remote programmed to a fan CHANGE LED COLOUR TEMPERATURE WITH LIGHT VERSION ONLY The light kit on the fan has three different colour temperature options 3000K 4000K 6000K To change the colour temperature using the remote control 1 Start with the light off and press the LIGHT ON OFF button three times within...

Page 11: ... chlorides this will increase maintenance requirements Even indoors in coastal areas the influx of warm sea air can accelerate the surface corrosion of metal parts This can still happen many kilometres from the sea When humidity is high and temperature drops moisture condenses on metal surfaces including ceiling fans The layer of moisture can be almost microscopic but it will affect the surface by...

Page 12: ... and ceiling structure is not moving Countersunk screws have been used Countersunk screws will make the fan wobble and eventually allow the bracket to move Replace Countersunk screws with screws that have been supplied in box Fan is noisy Loose Screws or Parts Check all screws and parts are secured firmly be careful to never over tighten the screws Ensure there are no loose parts moving inside the...

Page 13: ...e the original purchase receipt or bill of sale along with a proof of installation by a Licensed Electrician to make a warranty claim No claim will be accepted without these documents being provided Please contact AeroDC via the warranty hotline web or email Please note carefully If the product is found to be free of defects or the product is not functioning properly as a result of faulty installa...

Page 14: ...rary claims for damage to furniture carpet walls ceilings foundations or any other consequential loss either directly or indirectly resulting from a faulty ceiling fan 7 Signals sent through the mains power supply by the electricity supplier for off peak hot water and other signals including those for street lights and such These signals may cause an intermittent humming in the ceiling fan It is n...

Page 15: ...er Wall controllers must only be types approved for use by AeroDC 2 The fan fan light assembly and bracket are earthed 3 Fan fan light and remote control receiver are run from the same final circuit via an isolation switch 4 Mounting bracket must be firmly secured to a solid structure such as a concrete ceiling steel structure or timber framing If additional bracing is added it must be firmly secu...

Page 16: ... IN ACCORDANCE WITH LOCAL AUTHORITY REGULATIONS EM Imports Pty Ltd 10 Overlord Place Acacia Ridge Queensland Australia 4110 Warranty Support AeroDC Ph 1300 116 305 support aerodc com au National Warranty Hotline 1300 116 305 Monday to Friday 9am to 5pm AEST Distributed by ...

Reviews: