background image

NOTE: THIS FAN MUST BE INSTALLED BY A LICENSED AND QUALIFIED 

 

ELECTRICIAN IN ACCORDANCE WITH LOCAL AUTHORITY REGULATIONS 

1

IMPORTANT INFORMATION - PLEASE READ BEFORE ATTEMPTING INSTALLATION

Please Note:  Nothing  in  this  manual  is  intended  to  instruct  or  assist  untrained  or 

unqualified  persons  to  install  this  product.  Additionally,  it  is  the  responsibility  of  the 

installer and user to apply common sense and care at all times.

Please note: Minor design changes may result in slight variations between the product illustrations and the fan contained within the packaging.

1. 

Please read these instructions carefully, be mindful of all warnings and safety information shown throughout this 

manual. Should you have any questions, please contact 1300 116 305.

2. 

Please review the accompanying assembly diagrams before attempting installation.

3. 

This fan MUST be installed by a licensed & qualified electrician according to local authority regulations and in 

accordance with current wiring rules AS/NZS3000. Therefore, to protect our repair personnel, on-site warranty 

claims will not be accepted if products have been installed by unlicensed persons.

4. 

A copy of the purchasing receipt and proof of installation by a licensed and qualified electrician according to local 

authority regulations is required for all warranty claims.

5. 

Where special access equipment is required in accordance with local authority regulations all associated costs are 

the responsibility of the owner.

6. 

We reserve the right to charge a $175 service fee for all call outs where the fan is found not to be defective and 

/ or where access is not provided.

7. 

An isolation switch providing full disconnection of both fan and light must be fitted in accordance with the wiring 

rules (AS/NZS 60335.1 C1.7.12.2). In addition to all pole disconnection an isolation switch must be installed for 

each individual fan located in the same room to allow for programming and ongoing maintenance.

8. 

The Fan and Light (if supplied) must be earthed.

9. 

Your warranty will be void if a solid state dimmer or any other brand of wall or remote controller  is used.

10.  Installation using steel beams, grid ceilings and flexible structures are not recommended due to their inability to  

absorb vibration from normal operation. Timber is the recommended material to support the fan.

11.  To avoid possible electric shock during installation, be sure electricity is turned off at the main power box before 

commencing work. Disconnect power by removing fuse or turning off circuit breaker before installing the fan. 

Ensure all spliced connections are adequately insulated.

12.  Warning! Do not allow the rotating fan blades to come into contact with any object, this can cause serious injury 

or death.

13.  Damage caused by; incorrect installation, Force-majeure, lightning, electrical surges & spikes, exposure to water, 

pests or moisture is not covered under warranty.

14.  In  accordance  with  AS/NZS60355-1  &  ASNZS60355-2-80:  “This  appliance  is  not  intended  for  use  by  persons 

(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, 

unless they have been given supervision or instruction concerning use of the appliance by a person responsible for 

their safety. Children should be supervised to ensure that they do not play with the appliance.”

15.  Children should be supervised to ensure that they do not play with the appliance.
16.  Children shall not play with the appliance.
17.  Cleaning and user maintenance shall not be made by children.
18.  Blades must be replaced only as a complete set. Blades are supplied only as a pre-balanced set and the replacement 

of  individual  blades  may  void  the  warranty  by  causing  mechanical  damage  to  the  motor,  excessive  noise  or 

premature wear.

19.  Do not use outdoors where the fans could be directly exposed to water or moisture. Incorrect installation can be 

dangerous and will void the warranty. 

20.  No more than eight (8) DC fans per lighting circuit as this may cause intermittent tripping.

Summary of Contents for Profile DC

Page 1: ...AN FROM THE CEILING UNLESS INSTRUCTED TO DO SO National Warranty Number 1300 116 305 Monday to Friday 9am to 5pm AEST g NOTE THIS FAN MUST BE INSTALLED BY A LICENSED AND QUALIFIED ELECTRICIAN IN ACCORDANCE WITH LOCAL AUTHORITY REGULATIONS Australian Edition Version 2 5 October 2020 Installation User Manual PLEASE NOTE THE REMOTE CONTROL COMES PRE PROGRAMMED TO THE FAN ...

Page 2: ...m to allow for programming and ongoing maintenance 8 The Fan and Light if supplied must be earthed 9 Your warranty will be void if a solid state dimmer or any other brand of wall or remote controller is used 10 Installation using steel beams grid ceilings and flexible structures are not recommended due to their inability to absorb vibration from normal operation Timber is the recommended material ...

Page 3: ...ber frame is to be added it must be securely nailed or screwed between two beams After the fan is completely installed check to make sure that all connections are secure to prevent the fan from falling and or causing damage or injury To reduce the risk of personal injury do not bend or damage the motor or Fan Assembly when handling or during installation Please ensure special care is taken when as...

Page 4: ...istance To reduce the chance of marks or possible damage please only remove the parts when required for installation To avoid possible electrical shock be sure electricity is turned off at the main fuse box before assembling and wiring the fan WARNING Part Quantity Part Quantity Ceiling Bracket 1 Fan Motor 1 Ceiling Bracket Screws 2 ABS Blades 3 Ceiling Bracket Covers 2 Blade Screws 9 Receiver 1 B...

Page 5: ...ance of marks or possible damage please only remove the parts when required for installation To avoid possible electrical shock be sure electricity is turned off at the main fuse box before assembling and wiring the fan WARNING Handset Ceiling Bracket Ceiling Bracket Screws Fan Receiver Blades Blade Screws LED Light Kit Fan Motor Ceiling Bracket Screw cover Part Quantity Part Quantity Ceiling Brac...

Page 6: ...ower box or disconnect power by removing fuse or turning off circuit breaker This fan must be installed by a licensed and qualified electrician in accordance with local authority regulations INSTALLING FAN WITHOUT LIGHT In accordance with Australian Standards the fan blades must be at least 2 1 metres above floor level and the blades require at least 300mm clearance to the nearest object 1 3 2 4 5...

Page 7: ... power by removing fuse or turning off circuit breaker This fan must be installed by a licensed and qualified electrician in accordance with local authority regulations INSTALLING FAN WITHOUT LIGHT In accordance with Australian Standards the fan blades must be at least 2 1 metres above floor level and the blades require at least 300mm clearance to the nearest object 7 9 8 10 ...

Page 8: ...power box or disconnect power by removing fuse or turning off circuit breaker This fan must be installed by a licensed and qualified electrician in accordance with local authority regulations INSTALLING FAN WITH LIGHT In accordance with Australian Standards the fan blades must be at least 2 1 metres above floor level and the blades require at least 300mm clearance to the nearest object 1 3 2 4 5 6...

Page 9: ...t power by removing fuse or turning off circuit breaker This fan must be installed by a licensed and qualified electrician in accordance with local authority regulations INSTALLING FAN WITH LIGHT In accordance with Australian Standards the fan blades must be at least 2 1 metres above floor level and the blades require at least 300mm clearance to the nearest object 7 9 8 10 ...

Page 10: ...me remote can control multiple fans To remove a second remote see page 15 Removing a second remote programmed to a fan CHANGE LED COLOUR TEMPERATURE WITH LIGHT VERSION ONLY The light kit on the fan has three different colour temperature options 3000K 4000K 6000K To change the colour temperature using the remote control 1 Start with the light off and press the LIGHT ON OFF button three times within...

Page 11: ... chlorides this will increase maintenance requirements Even indoors in coastal areas the influx of warm sea air can accelerate the surface corrosion of metal parts This can still happen many kilometres from the sea When humidity is high and temperature drops moisture condenses on metal surfaces including ceiling fans The layer of moisture can be almost microscopic but it will affect the surface by...

Page 12: ... and ceiling structure is not moving Countersunk screws have been used Countersunk screws will make the fan wobble and eventually allow the bracket to move Replace Countersunk screws with screws that have been supplied in box Fan is noisy Loose Screws or Parts Check all screws and parts are secured firmly be careful to never over tighten the screws Ensure there are no loose parts moving inside the...

Page 13: ...e the original purchase receipt or bill of sale along with a proof of installation by a Licensed Electrician to make a warranty claim No claim will be accepted without these documents being provided Please contact AeroDC via the warranty hotline web or email Please note carefully If the product is found to be free of defects or the product is not functioning properly as a result of faulty installa...

Page 14: ...rary claims for damage to furniture carpet walls ceilings foundations or any other consequential loss either directly or indirectly resulting from a faulty ceiling fan 7 Signals sent through the mains power supply by the electricity supplier for off peak hot water and other signals including those for street lights and such These signals may cause an intermittent humming in the ceiling fan It is n...

Page 15: ...er Wall controllers must only be types approved for use by AeroDC 2 The fan fan light assembly and bracket are earthed 3 Fan fan light and remote control receiver are run from the same final circuit via an isolation switch 4 Mounting bracket must be firmly secured to a solid structure such as a concrete ceiling steel structure or timber framing If additional bracing is added it must be firmly secu...

Page 16: ... IN ACCORDANCE WITH LOCAL AUTHORITY REGULATIONS EM Imports Pty Ltd 10 Overlord Place Acacia Ridge Queensland Australia 4110 Warranty Support AeroDC Ph 1300 116 305 support aerodc com au National Warranty Hotline 1300 116 305 Monday to Friday 9am to 5pm AEST Distributed by ...