4
© Aero-Stream, LLC 2022
102822 Rev. H
Tanks
The Aero-Stream aerobic treatment units have been certified in pre-cast concrete tanks. The Appendix
of this manual includes alternate construction poly tanks that have been approved by NSF for use with
the Aero-Stream aerobic treatment units.
The certified installer shall provide the model number, drawings and specifications of the poly tank or
the pre-cast tank configuration to Aero-Stream engineering for review to ensure compliance to the
ANSI/NSF 40 standard.
The details of every aerobic treatment unit installation shall be recorded and be available to NSF during
auditing. The record shall be maintained by Aero-Stream or the authorized representative. The
installation record shall include the following:
1. The model number o
f the tank and the manufacturer’s contact information.
2. A fully dimensioned drawing of each tank.
3. Documentation demonstrating compliance with all state and local codes for the location where the
tank is installed.
4. Documentation demonstrating tank compliance with the structural and water tightness requirement of
ANSI/NSF standard 40/245.
5.
Engineer’s review including stamped letter or stamped drawings, or documentation demonstrating
tank certification to either CSA B66, IAPMO/ANSI Z1000 or IGC 262.
6. If an existing tank is used, the following requirements must be met:
1. The tank must meet the criteria listed in Table 1.
2. Approved by Aero-Stream, LLC Engineering
3. Pump tank by a licensed contractor.
4. Clean and confirm tank condition including water tightness
7. Septic tank must contain a four (4) inch sanitary tee baffle. The outlet filter housing design and
installation based on the approved plans.
Model Number
AS450-2
AS500-2
AS600-2
AS750-2
AS1000-2
AS1500-2
Drawing Number
102805
102928
102848
102854
102860
102867
Tank Volume (Total)
900-1250
900-1250
1200-1650
1500-2100
1750-2500
2700-3750
Chamber Volume
(Nominal)
500
500
670
835
1000
1500
Chamber Volume
Range
450-625
450-625
600-825
750-1050
875-1250
1350-1875
Compressor
AS1000
(ED:101)
AS1200
(ED:102)
AS1200
(ED:102)
AS1400
(ED:103)
2 - AS1200
(ED:102)
3 - AS1200
(ED:102)
Max LL
72
72
72
72
72
72
Min LL
38
38
38
38
38
38
# of 102302 Diffusers
@ = or >44 LL
1
1
1
1
2
3
# of 120845 Diffusers
@>38 & <44 LL
2
2
2
2
3
3
Cluster configuration
(W*D)
2 * 3
2 * 3
3 * 3
3 * 4
3 * 5
4 * 5
Aero-Alert
Pressure/High Water
Alarm
Yes
Yes
Yes
Yes
Yes
Yes
Gas Deflector
Yes
Yes
Yes
Yes
Yes
Yes
Table 1, System Requirements
Summary of Contents for AS1000-2
Page 8: ...8 Aero Stream LLC 2022 102822 Rev H Figure 4 Picture of the AS450 2 System ...
Page 9: ...9 Aero Stream LLC 2022 102822 Rev H Figure 5 Picture of the AS500 2 System ...
Page 10: ...10 Aero Stream LLC 2022 102822 Rev H Figure 6 Picture of the AS600 2 System ...
Page 11: ...11 Aero Stream LLC 2022 102822 Rev H Figure 7 Picture of the AS750 2 System ...
Page 12: ...12 Aero Stream LLC 2022 102822 Rev H Figure 8 Picture of the AS1000 2 System ...
Page 13: ...13 Aero Stream LLC 2022 102822 Rev H Figure 9 Picture of the AS1500 2 System ...