aero pure AP100-RVL Installation Manual Download Page 4

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with the homeowner.

4

REPLACEMENT INSTALLATION 

Remove

t he screws

Wire Panel

Wire Panel 

Remove

 the screws

SERVICE PARTS

PART

PART NAME

Qty.

1a

1b

2

3

4

5

6

7

9

10

Blower Wheel

Motor plate

Wiring plate

Wire Panel / Harness Assembly

Trim Ring
( AP80-RVL & AP80H-RVL & AP100-RVL & AP100-RVL)

Trim Ring

 ( AP80-QVL & 

AP80H-QVL

)

Grille Spring

Lamp base

Motor

Duct

1

1

1

2

1

1

4

1

1

1

1

1

8

Blower housing

1

11

12

13

Housing

1

Hanger Bars

3

2
1a

1b

5

4

6

7

8

9

10

11

6

12

13

Humidity Sensor System

 

(AP80H-QVL&AP80H-RVL)

WARRANTY 

This warranty covers all defects in workmanship or materials for:
The mechanical and electrical parts contained in this product for a period of 72 months from the date of purchase. You
must keep and be able to provide your original sales receipt as proof of date of purchase. This warranty is covered to the
original retail purchaser of this product only. The manufacturer will replace any mechanical or electrical part that proves
defective in normal household use for a period of 72 months.

THIS WARRANTY DOES NOT COVER:
• Damages from improper installation.
• Damages from shipping.
• Damages from misuse, abuse, accident, alteration, lack of proper care and maintenance.
• Damages from service by persons other than a licensed electrician.
• Does not cover any labor or transportation charges related to the repair of this product.

This warranty does not extend to fluorescent lamp starters and tubes or any light bulbs..

THIS LIMITED WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING
THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

The remedy provided in this warranty is exclusive and is granted in lieu of all other remedies.

This warranty does not

cover incidental or consequential damages. Some states do not allow the exclusion of incidental or consequential
damages, so this limitation may not apply to you. Some states do not allow limitations on how long an implied warranty
lasts, so this limitation may not apply to you. This warranty gives you specific legal rights; you may also have other rights
that vary from state to state.

8.

 To replace the capacitance you will need to remove the wire panel, 

 and then replace the capacitance.    

Summary of Contents for AP100-RVL

Page 1: ...LLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switching on accidentally If the service disconnecting means cannot be locked secure...

Page 2: ...bars may be used on all types of framing I joist standard joist and truss construction Slide hanger bars onto housing and adjust as needed to fit between framing 1b Extend the hanger bars to the width of the framing Position the fan with the hanger bar tabs aligned with the bottom edge of the framing holding the ventilator in place Secure hanger bars to framing using one screw on each end of hange...

Page 3: ...n 3 2mm Fluorescent lamp Hanger bar Ceiling Joist After finishing the ceiling job fill gap between flange and ceiling with caulk or other sealant to prevent air leakage 1 8 in 3 2mm 6 1 2 in 1 65 m m Wing nut Lamp base Remove the screws Lamp base Blower system Remove the screws Remove the screws WIRE PANEL UNIT BLACK BLK LIGHT SWITCH BOX FAN POWER SUPPLY 120V AC GROUND GRD BLUE BLU WHITE WHT FAN R...

Page 4: ...usehold use for a period of 72 months THIS WARRANTY DOES NOT COVER Damages from improper installation Damages from shipping Damages from misuse abuse accident alteration lack of proper care and maintenance Damages from service by persons other than a licensed electrician Does not cover any labor or transportation charges related to the repair of this product This warranty does not extend to fluore...

Page 5: ...www aeropurefans com 5 AP100H RVL AP80 RVL AP80H RVL AP80H QVL AP80 QVL AP100 RVL ...

Page 6: ...A 6 ...

Page 7: ...MIDITÉ BRUN BRN AP80H RVL AP80H QVL Joist Lamp base Wing nut Fluorescent lamp Ceiling After finishing the ceiling job fill gap between flange and ceiling with caulk or other sealant to prevent air leakage Remove the screws Blower system Lamp base Remove the screws Remove the screws Hanger bar 6 1 2 in 165m m 1 8 in 3 2mm 1 8 in 3 2mm 6 1 2 in 1 65 m m AP80 RVL AP100 RVL AP80 QVL ...

Page 8: ...ews Wire Panel 1a 2 3 4 5 6 7 9 10 1 1 2 1 1 4 1 1 1 1 1 8 1 11 12 13 1 3 2 5 4 6 7 8 9 10 11 6 12 13 Du détecteur d humidité AP80H RVL AP80H QVL 8 1a 1b AP80 RVL AP80H RVL AP100 RVL AP100 RVL 1b 1 AP80 QVL AP80H QVL ...

Page 9: ...DESCARGA ELÉCTRICA O LESIONES A PERSONAS LEA LO SIGUIENTE 1 Utilice esta unidad únicamente de la manera prevista por el fabricante Si tiene preguntas póngase en contacto con el fabricante a la dirección o al número de teléfono que figuran en la garantía 2 Antes de realizar labores de mantenimiento o limpiar la unidad apáguela desde el panel de servicio y bloquee el sistema de desconexión de servic...

Page 10: ...ción corta 30 90 cm de conducto flexible aislado garantizará un funcionamiento silencioso PLANIFICACIÓN DE LA INSTALACIÓN No lo utilice en un área de cocina Dos formas de conectar los conductos a una unidad de fábrica CUBIERTA DE TECHO con compuerta incorporada CONDUCTO REDONDO compra por separado CARCASA DEL VENTILADOR CODO S REDONDO S Selle las uniones de los conductos con cinta Mantenga los con...

Page 11: ... un orificio redondo en el techo de 165 mm 6 1 2 pulgadas de diámetro Selle cualquier hueco entre el orificio de la pared de yeso y el ventilador con sellador 2 Instale la lámpara fluorescente compacta o LED Lámpara no incluida 3 Se puede ajustar el alojamiento de la lámpara hacia arriba o hacia abajo para acomodar diferentes lámparas La unidad es apta para el uso de un adaptador y lámpara GU24 1 ...

Page 12: ...sulte defectuosa en el uso doméstico normal por un período de 72 meses ESTA GARANTÍA NO CUBRE Daños por instalación incorrecta Daños por el transporte Daños por mal uso abuso accidente alteración falta de cuidado y mantenimiento adecuados Daños causados por la asistencia de personas que no sean electricistas autorizados No cubre los gastos de mano de obra o transporte relacionados con la reparació...