aero pure AP100-RVL Installation Manual Download Page 1

MODEL: AP80-RVL

AP80H- RVL

AP80H- QVL

AP80-QVL

RECESSED FAN LIGHT

www.aeropurefans.com

Use an on/off switch to operate this fan. See “Connect Wiring” for details. 
The humidity control and fan can be operated separately. Can be used with a dual “stacked” switch for fan / light control. Do not use a dimmer switch 
to operate the humidity control or light. See “Connect Wiring” for details. 

For AP80H-RVL & AP80H-QVL & AP100H-RVL
SENSOR OPERATION 

The humidity-sensing fan uses a sophisticated humidity sensor that responds to: (a) rapid to moderate (user-adjustable) increases in humidity or (b) 
humidity rate above a user-adjustable set-point (30%-80% relative humidity). The humidity sensor may occasionally turn the fan ON when 
environmental conditions change. If the fan continuously responds to changing environmental conditions, adjustment may be required. The fan  is 
factory-set for 80% (with a ambient temperature of 77 degree F) 

SENSITIVITY ADJUSTMENT (H)

The “H” has been factory set for most shower applications. However, if the fan is in a tub area or is being used for dampness control, the “H” 
may need to be increased toward maximum “+”. If the control is responding too often to changing environmental conditions, movement toward less “-” 
“H” may be required. To adjust the “H”: 
1. Disconnect power at service entrance. 
2. Through the grille, locate the slot marked “H”. 
3. Carefully rotate the “H” adjustment toward “+” or “-”. 
4. Turn on power and check operation by turning on the shower or other humidity source until the fan turns on. 
5. Repeat above steps if necessary. 
When the ambient temperature changes, the humidity sensor values will deviate slightly. 

TIMER ADJUSTMENT (T) 

The “T” on the control panel will adjust the time delay from 5 to 60 minutes (factory pre-set at  20 minutes). This “T” controls the length of time that the 
fan remains ON after the sensor has stopped sensing a rise in humidity and the humidity level is below the user-adjustable set-point. To adjust the “T”: 
1. Disconnect power at service entrance;                                                                 
2. Through the grille, locate the slot marked “T”; 
3. Carefully rotate the “T” adjustment to desired setting (from 5 to 60 minutes).      
4. Check operation by turning on a humidity source until the fan turns on. 
5. Turn humidity source off and time the unit.                                                           
6. Repeat above steps if necessary. 

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, PLEASE READ THE FOLLOWING: 

1

. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number

listed in the warranty.

2

.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power

from being switching on accidentally. If the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag,
to the service panel.

3

. Installation work and electrical wiring must be done by a licensed person(s) in accordance with all applicable codes and

standards, including fire-rated construction codes and standards.

4

. Sufficient air is needed for proper combustion and exhausting of gases through

the flue (chimney) of fuel burning equipment to prevent backdraft. Follow the heating equipment manufacturer’s guideline and safety standards such
as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.

5

. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden

utilities.

6.

Ducted fans must always be vented to the outdoors.

7

. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault

Circuit Interrupter) - protected branch circuit.

8

. This unit must be grounded.

9

. Never place a switch where it can be reached from a tub or shower.

10.

WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.

11

. The fan must not be

installed in a ceiling thermally insulated to a value greater than R40.

CAUTION 

1

. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

2

. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must be horizontal. DO NOT

MOUNT THIS PRODUCT IN A WALL.

3

. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

4

. Please read specification label on product for further information and requirements.

CLEANING & MAINTENANCE 

For quiet and efficient operation, long life, and attractive appearance lower or remove grille and vacuum interior of unit with the dusting brush
attachment.

The motor is permanently lubricated and never needs oiling.

OPERATION 

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with the homeowner.

Cod

0060300920-E

AP100-RVL

AP100H-RVL

Summary of Contents for AP100-RVL

Page 1: ...LLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switching on accidentally If the service disconnecting means cannot be locked secure...

Page 2: ...bars may be used on all types of framing I joist standard joist and truss construction Slide hanger bars onto housing and adjust as needed to fit between framing 1b Extend the hanger bars to the width of the framing Position the fan with the hanger bar tabs aligned with the bottom edge of the framing holding the ventilator in place Secure hanger bars to framing using one screw on each end of hange...

Page 3: ...n 3 2mm Fluorescent lamp Hanger bar Ceiling Joist After finishing the ceiling job fill gap between flange and ceiling with caulk or other sealant to prevent air leakage 1 8 in 3 2mm 6 1 2 in 1 65 m m Wing nut Lamp base Remove the screws Lamp base Blower system Remove the screws Remove the screws WIRE PANEL UNIT BLACK BLK LIGHT SWITCH BOX FAN POWER SUPPLY 120V AC GROUND GRD BLUE BLU WHITE WHT FAN R...

Page 4: ...usehold use for a period of 72 months THIS WARRANTY DOES NOT COVER Damages from improper installation Damages from shipping Damages from misuse abuse accident alteration lack of proper care and maintenance Damages from service by persons other than a licensed electrician Does not cover any labor or transportation charges related to the repair of this product This warranty does not extend to fluore...

Page 5: ...www aeropurefans com 5 AP100H RVL AP80 RVL AP80H RVL AP80H QVL AP80 QVL AP100 RVL ...

Page 6: ...A 6 ...

Page 7: ...MIDITÉ BRUN BRN AP80H RVL AP80H QVL Joist Lamp base Wing nut Fluorescent lamp Ceiling After finishing the ceiling job fill gap between flange and ceiling with caulk or other sealant to prevent air leakage Remove the screws Blower system Lamp base Remove the screws Remove the screws Hanger bar 6 1 2 in 165m m 1 8 in 3 2mm 1 8 in 3 2mm 6 1 2 in 1 65 m m AP80 RVL AP100 RVL AP80 QVL ...

Page 8: ...ews Wire Panel 1a 2 3 4 5 6 7 9 10 1 1 2 1 1 4 1 1 1 1 1 8 1 11 12 13 1 3 2 5 4 6 7 8 9 10 11 6 12 13 Du détecteur d humidité AP80H RVL AP80H QVL 8 1a 1b AP80 RVL AP80H RVL AP100 RVL AP100 RVL 1b 1 AP80 QVL AP80H QVL ...

Page 9: ...DESCARGA ELÉCTRICA O LESIONES A PERSONAS LEA LO SIGUIENTE 1 Utilice esta unidad únicamente de la manera prevista por el fabricante Si tiene preguntas póngase en contacto con el fabricante a la dirección o al número de teléfono que figuran en la garantía 2 Antes de realizar labores de mantenimiento o limpiar la unidad apáguela desde el panel de servicio y bloquee el sistema de desconexión de servic...

Page 10: ...ción corta 30 90 cm de conducto flexible aislado garantizará un funcionamiento silencioso PLANIFICACIÓN DE LA INSTALACIÓN No lo utilice en un área de cocina Dos formas de conectar los conductos a una unidad de fábrica CUBIERTA DE TECHO con compuerta incorporada CONDUCTO REDONDO compra por separado CARCASA DEL VENTILADOR CODO S REDONDO S Selle las uniones de los conductos con cinta Mantenga los con...

Page 11: ... un orificio redondo en el techo de 165 mm 6 1 2 pulgadas de diámetro Selle cualquier hueco entre el orificio de la pared de yeso y el ventilador con sellador 2 Instale la lámpara fluorescente compacta o LED Lámpara no incluida 3 Se puede ajustar el alojamiento de la lámpara hacia arriba o hacia abajo para acomodar diferentes lámparas La unidad es apta para el uso de un adaptador y lámpara GU24 1 ...

Page 12: ...sulte defectuosa en el uso doméstico normal por un período de 72 meses ESTA GARANTÍA NO CUBRE Daños por instalación incorrecta Daños por el transporte Daños por mal uso abuso accidente alteración falta de cuidado y mantenimiento adecuados Daños causados por la asistencia de personas que no sean electricistas autorizados No cubre los gastos de mano de obra o transporte relacionados con la reparació...

Reviews: