5
IVES0LJ 1707 - 5880761_01
IMPORTANT INFORMATION AND MAINTENANCE
AT TENTION : the fan coil is
connected to the power supply and
the hydraulic circuit. Operations
performed by persons who do not
have the required technical skills
can lead to personal injury to the
operator or damage to the unit and
the surrounding environment.
SUPPLY THE FAN COIL ONLY WITH
VOLTAGE 230V ~ 50Hz
The fan coil may be permanently
damaged if a different electric power
supply is used.
D O N O T U S E T H E FA N C O I L
IMPROPERLY
The fan coil must not be used to breed,
deliver and raise animals.
AIR OUT THE ROOM
Periodically air out the room in which
the fan coil has been installed; this is
particularly important if the room is
occupied by many people, or if there are
gas appliances or sources of odours.
A D J U S T T H E T E M P E R AT U R E
CORRECTLY
Ambient temperature should be regulated
to ensure maximum comfort, particularly
for the elderly, infants and invalids.
Prevent temperature fluctuations
between indoors and outdoors greater
than 7°C during summer.
Excessively low temperatures during
summer involve higher electrical
consumption.
DIRECT THE AIR FLOW CORRECTLY
Air delivered by the fan coil must not
be directed onto people. Even if the
air temperature is higher than the
ambient temperature, it can cause a cold
sensation and, therefore, discomfort.
DO NOT USE WATER THAT IS TOO HOT
Clean the fan coil by using soft cloths or
sponges with warm water at a maximum
temperature of 40°C. Do not use
chemical products or solvents on any
part of the fan coil. Do not spray water
on internal or external surfaces of the fan
coil (danger of short circuits).
CLEAN THE FILTER PERIODICALLY
Frequent cleaning of the filter will ensure
more efficient operation.
Check if the filter is excessively dirty.
Repeat the operation more frequently, if
required.
Clean often and use a suction device to
remove accumulated dust.
When the filter is clean, reassemble it onto
the fan coil by following the removal
procedure in reverse order.
EXTRAORDINARY CLEANING
Removing the augers of the inspected fans
(which can be carried out only by qualified
personnel) allows the internal parts to be
cleaned accurately. This is essential for
installation in very crowded areas or that
require high hygienic standards.
DURING OPERATION
Always leave the filter mounted on the fan
coil during operation, otherwise the dust in
the air will dirty the surface of the coil.
IT IS NORMAL
When in cooling mode, water vapour can
come out of the fan coil air flow.
When in heating mode, a slight hissing
sound can be heard near the fan coil. The
fan coil may sometimes emit unpleasant
odours due to the accumulation of
substances present in the environment
(clean the filter more often, especially if
the room is not aired out regularly).
During operation, noise and/or a creaking
sound may be heard from inside the
device due to the heat expansion of the
elements (plastic and metal), however,
this does not indicate a fault and does
not cause damage to the unit unless the
maximum input water temperature is
exceeded.
OPERATION ANOMALIES
In case of anomalous operation,
disconnect the voltage from the unit
and then re-apply it and re-start the
appliance.
ATTENTION! Do not try to repair the
unit on your own, as it may be very
dangerous!
If the problem persists, call the Area
After-sales Service immediately.
DO NOT PULL THE ELECTRIC CABLE
It is very dangerous to pull, step on or
crush the power supply cable or secure it
using nails or staples.
The damaged cable can cause short
circuits and injury to persons.
DO NOT INTRODUCE OBJECTS INTO
AIR VENTS
Do not introduce objects in the air outlet
and inlet.
This could cause injury to persons or
damage the fan.
ATTENTION
Do not allow the appliance to be used
by children or disabled people without
appropriate supervision. Remember that
children must not use the appliance as
a toy.
AIR FILTER REMOVAL AND REASSEMBLY
To clean the air filter remove it from the
fan coil.
The clean or new (replaced) air filter
must be mounted and locked in place
properly in the fan coil.
To remove the air filter:
- loosen the screws of the two filter
retainers
- make the two filter retainers slide all the
way
- pull the filter out of its seat
To remount the clean air filter:
- insert the air filter into its seat,
- make the two filter retainers slide until
locking the filter in place,
- tighten the screws of the two filter
retainers,
- make sure that the filter is locked in
place.
Refer to the control panel manual for the operating and installation instructions.
USE
The fan coils are delivered with standard packaging consisting in expanded polystyrene and cardboard covering.
PACKAGING
Summary of Contents for VES030
Page 1: ...VES030 VES040 VES130 VES140 VES230 VES240 VES330 VES340 IVES0LJ 1707 5880761_01 ...
Page 2: ...OSSERVAZIONI REMARKS REMARQUES OBSERVACIONES HINWEISE ...
Page 50: ...VES_I030 VES_I040 VES_I130 VES_I140 VES_I230 VES_I240 VES_I330 VES_I340 5880751_01 17 07 ...
Page 51: ...OSSERVAZIONI REMARKS REMARQUES OBSERVACIONES HINWEISE ...
Page 59: ...10 5880751_01 TECHNICAL DATA ...