INSTALLATION, USE AND MAINTENANCE MANUAL
GENERAL SAFETY PRESCRIPTIONS
ATTENTION!
The TA series units are intended for the civil and tertiary
sector: any other use (in highly corrosive environments,
in the presence of potentially explosive atmospheres,
etc.) is not permitted.
Installation and maintenance
Make sure the unit has not been damaged during transport before
installation. Using a damaged machine could be dangerous.
Installation and special maintenance must be carried out by personnel
with the necessary requisites in accordance with current regulations.
Do not use the unit as storage for equipment or spare parts. Any use
other than that indicated in this manual is prohibited as it can generate
dangerous situations.
Before performing maintenance or cleaning, make sure that the unit is
not live and that it cannot be powered without the operator knowing
it.
During maintenance and cleaning, pay attention to scalding deriving
from any heating coils.
Before starting the unit, make sure that the electrical components have
been connected to the building’s earth plant.
Use suitable Personal Protective Equipment (PPE) and tools during the
installation, maintenance and cleaning stages.
Unit access
Only operators and qualified technicians may access the unit once it
is installed. By operator we mean a person authorised by the owner
of the machine to perform operations on it (in compliance with that
provided in this manual). By technician we mean a person authorised
by AERMEC or under the full responsibility of an AERMEC distributor
to perform operations on the machine. By machine owner we mean
the legal representative of the company, body or physical person
who owns the system on which the AERMEC unit is installed. He is
responsible to make sure that all safety standards indicated in this
manual and standards in force are complied with. Since this unit is
generally installed on a suspended ceiling, the lower panelling must
be accessible in order to inspect the filters and fans.
Residual risks
Installation, start-up, shutdown and maintenance of the unit must be
carried out in compliance with that provided in the product’s technical
documentation and anyhow in such a way as not to create any situation
of risk. The unit has been designed to reduce risks for the safety of the
persons interacting with it to a minimum. During designing, it was not
technically possible to fully eliminate the causes of risks. Therefore it is
absolutely necessary to refer to the following prescriptions.
CONCERNED PART
RESIDUAL RISK
MODE
PRECAUTIONS
Inside unit: heat exchange
finned coil
small cuts
contact
avoid contact, use protective gloves
Electric heating coil
burns, injuries
contact
avoid contact
Inside unit: metal parts and
electric cables
intoxication, electrocution,
serious burns
faulty insulation of power cables
upstream electric control board of
unit; live metal parts
adequate electric protection of power
line; utmost care when earthing metal
parts
Outside of unit: zone around
unit
serious burns
fire caused by short-circuit or
overheating of power line upstream
electric control board of unit
cross-section of cables and protective
system of electric power line in
compliance with standards in force
Summary of Contents for TA 09
Page 2: ......
Page 51: ...51 WIRING DIAGRAMS TA09 E WMT05 PE L N 230V 50Hz IG MAX MED MIN ...
Page 52: ...52 TA09 E WMT06 PE L N 230V 50Hz IG VF VC MAX MED MIN ...
Page 53: ...53 TA09 E WMT10 PE L N 230V 50Hz IG VF VC MAX MED MIN ...
Page 56: ...56 TA19 24 CON WMT05 E MOTORE CMC PE L N 230V 50Hz IG KA1 KA2 KA3 MAX MED MIN ...
Page 57: ...57 TA19 24 CON WMT06 E MOTORE CMC PE L N 230V 50Hz IG KA1 KA2 KA3 VC VF MAX MED MIN ...
Page 58: ...58 TA19 24 CON WMT10 E MOTORE CMC PE L N 230V 50Hz IG KA1 KA2 KA3 VC VF MAX MED MIN ...
Page 59: ...59 TA33 50 CON WMT05 E MOTORE CMC PE L N 230V 50Hz IG KA1 KA2 KA3 MAX MED MIN MAX MED MIN ...
Page 69: ...69 STO MAX MED MIN 82 82 38 PX mm PX mm ...
Page 70: ......
Page 71: ......