AERMEC FK260 Use And Installation  Manual Download Page 7

7

Aermec. 16.01. 5140901_01

2. 

UNIT TYPE

The air conditioners are of the air condensed 

FK monoblock type, ideal for cooling, 

dehumidifying or just ventilation.

Perfect for applications in commercial 

environments such as stores, hotels, offices, 

laboratories, prefabricated sheds, etc.

These units are equipped, as standard, by a 

front control panel on the machine, as well as 

a remote control device.

3. 

FEATURES

• 

Operation with R32 eco-friendly coolant gas

• 

Centrifugal fan evaporator side and axial fan condenser side

• 

Scroll compressor

• 

Infra-red remote control

• 

Control panel on the machine

• 

Compact unit with reduced dimensions

• 

Three possible functions:

 - 

Cooling

 - 

Dehumidification

 - 

Ventilation only

• 

Class A energy efficiency

• 

Contained sound emissions

• 

Plug and play

• 

Possibility to adjust the flow of air upward or downward.

• 

Timer for setting operation with a clock (turning on or switching off).

• 

Easy installation and maintenance 

• 

Automatic operating modes suitable for the various installation contexts (room, office, restaurant).

FK 260

FK 360

AUTO
COOL
DRY
FAN
HEAT

SWING
SLEEP

T-ON T-OFF

LOCK
SPEED

+

_

ON/OFF

FAN

WING

S

SLEEP

TIMER

MODE

Remote control 

remote

Schuko Plug

Front control panel

Structure

External grille

Air filter

(device behind 

the front grille)

Front grille

External grille

Summary of Contents for FK260

Page 1: ...EN USE AND INSTALLATION MANUAL Aermec 16 01 5140901_01 FK260 FK360 Energy efficiency A 5140901_01...

Page 2: ...NS FOR INSTALLATION OF THE UNIT 10 7 2 POSITIONING 10 7 3 MINIMUM TECHNICAL CLEARANCES 11 7 4 CONDENSATE DRAINAGE 11 7 5 ELECTRICAL WARNINGS 12 7 6 UNIT DIMENSIONS 12 8 WIRING DIAGRAMS 13 9 OPERATING...

Page 3: ...laws All specifications are subject to change without prior notice Although every effort has been made to ensure precision Aermec does not assume any responsibility for any errors or omissions Dear c...

Page 4: ...Y ONLY BE FOLLOWED BY SPECIALISED TECHNICIANS OR QUALIFIED PERSONNEL Make sure that other types of coolant do not contaminate the R32 The gas tank must be kept in a vertical position during filling Ap...

Page 5: ...s Service these operations must only be carried out by Personnel with the specific technical skills Ensure that the power supply and the installed output are adequately scaled to supply the air condit...

Page 6: ...cally check that the installation conditions of the unit have not been altered and have the system checked by a qualified engineer Do not remove the protection grilles Do not insert your hands or any...

Page 7: ...remote control Control panel on the machine Compact unit with reduced dimensions Three possible functions Cooling Dehumidification Ventilation only Class A energy efficiency Contained sound emissions...

Page 8: ...enser attachment diameter mm 7 7 Fan Type Axial Axial Air flow rate m3 h 800 1200 Sound pressure maximum dB A 56 58 Sound pressure medium dB A 54 56 Sound pressure minimum dB A 52 54 Sound power maxim...

Page 9: ...9 Aermec 16 01 5140901_01 6 DESCRIPTION OF COMPONENTS Inner side Air filter Outer side...

Page 10: ...the air delivery and intake sockets in the internal part so that air can circulate freely Ensure the installation complies with the minimum technical clearances specified in the installation diagram...

Page 11: ...re starting up the unit Slide the frame of the unit from the base Install the drainage tub on the corner and fix it with two screws as shown in the figure Connect the drainage pipe NOT provided to the...

Page 12: ...Ensure that the earthing cable is connected to the building s earthing connection system Ensure that a differential switch suitable for leaks to the ground is installed Do not connect the earth cable...

Page 13: ...tilator PE W V U N AC L AP1 BN M BU YEGN BU YE RD Kompressor CN1 W V U YEGN 2 XT 1 berstrom ausl ser RD RD WARNUNG 15K 50K 20K CN3 RT1 RT2 RT3 WH BK Temp F hler Lufteintritt Temp F hler Register Temp...

Page 14: ...e or generate noise Has a check for refrigerant leaks been performed Poor performance Is the thermal insulation sufficient It could cause condensate and dripping water Does the unit correctly drain th...

Page 15: ...hese steps the filter is still dirty fill a tub with lukewarm water and some non aggressive cleanser and soak it for a few minutes Next dry it with a cloth 5 Otherwise have a specialised technician cl...

Page 16: ...to select the fan speed 5 SWING button Press this button to select the fan mode from left to right 6 TIMER button Timer function for setting the time the unit is switched on or off Temp function to se...

Page 17: ...d FAN Ventilation only mode the unit operates in ventilation mode In this case press the FAN button repeatedly to adjust the ventilation speed 3 button Function 1 Pressing or once will increase or red...

Page 18: ...GRAMMED START UP FUNCTION When the unit is turned off pressed the Timer button to set the programmed start up function The T ON and H icons on the display will start to blink In 5 seconds press the bu...

Page 19: ...careful not to invert the polarity Close the battery cover NOTE When batteries are replaced use new batteries of the recommended type Remove the batteries if the remote control is not used for extende...

Page 20: ...room temperature We recommend that you do not keep the air jets direct instead set the unit to Swing mode Make sure the doors and windows are closed well Avoid opening the doors and windows of the roo...

Page 21: ...ssor protection from overloading Contact specialised personnel or the Aermec Assistance Service L9 Power supply protection Contact specialised personnel or the Aermec Assistance Service H5 Module temp...

Page 22: ...suggested by the producer of the material The unit must be installed in a space that respects the minimum allowed dimensions Please carefully observe the following table Verify that the maintenance ar...

Page 23: ......

Page 24: ...le droit de modifier tous moments les donn es consid r es n cessaires l amelioration du produit Technical data shown in this booklet are not binding Aermec S p A shall have the right to introduce at a...

Reviews: