background image

IT

EN

FR

DE

ES

10

&WͺWKͺϭϲϬϱͳϲϰϱϲϬϲϯͺϬϮ

GENERAL WARNINGS

•  WARNINGS REGARDING SAFETY AND INSTALLATION 

STANDARDS 

• 

Follow the indications below to install the equipment correctly. 
The completion of all operations, according to specific 
requirements, is left to the experience of the installer.

• 

Do not modify or tamper with the units, as dangerous situations 
can occur. The manufacturer will not be liable for any damage 
caused. The validity of the warranty shall be void in the event of 
failure to comply with the indications mentioned in this manual.

• 

Before starting any operations, READ THESE INSTRUCTIONS 
CAREFULLY AND CARRY OUT THE SAFETY CHECKS TO AVOID ALL 
RISKS. 

• 

All the staff involved must have thorough knowledge of the 
operations and any danger that may arise when the installation 
operations are carried out.

• 

The unit must be installed to facilitate routine (filter cleaning) and 
special maintenance operations.

• 

 ATTENTION: the fan coil is connected to the power supply 

and the hydraulic circuit. Operations performed by persons who 
do not have the required technical skills can lead to personal 
injury to the operator or damage the unit and the surrounding 
environment.

• 

 ATTENTION: The unit must be installed in compliance with 

national regulations.

• 

 ATTENTION: make sure that the power supply has been 

disconnected before carrying out any interventions.

• 

 ATTENTION: Install a device, master switch or electric plug that 

allows the unit’s power supply to be completely disconnected.

• 

 ATTENTION: In order to protect the unit against short circuits, 

mount a magnet circuit breaker omnipolar switch on the power 
supply line.  In order to avoid any danger due to the accidental 
rearming of the thermal cut-out device, this appliance must 
not be powered with an external switching device, such as a 
timer, or be connected to a circuit that is regularly powered or 
disconnected from the service. 

• 

 ATTENTION! DANGER! Any use other than what is indicated 

by Aermec is prohibited. 

• 

 Supply the fan coil only with the voltage value indicated in 

the data plate

• 

The fan coil may be permanently damaged if a different electric 
power supply is used.

• 

 OPERATION ANOMALIES

• 

In the event of operation anomalies, power off the unit and then 
power it back on and re-start the unit. 

• 

Do not try to repair the unit on your own, as it may be very 
dangerous!

• 

If the problem persists, call the Area After-sales Service 
immediately.

• 

 Do not pull the electric cable

• 

It is very dangerous to pull, step on or crush the power supply 
cable or secure it using nails or staples.

• 

The damaged cable can cause short circuits and injury to persons.

• 

 Electric power supply cable

• 

If the power supply cable is damaged, it must be replaced with 
a new cable of adequate section. Have the repair made by 
"Qualified personnel", in order to prevent any risk.

• 

Do not repair damaged cables.

• 

For the electric power supply, use integral cables with suitable 
section for the load.

• 

 Do not introduce objects into air vents

• 

Do not introduce any objects into the air outlet slots.

• 

This could cause injury to persons or damage the fan.

• 

INFORMATION

• 

• 

The FCZ AERMEC units are constructed according to the 
recognised technical standards and safety regulations. They 
have been designed and must be used for air conditioning and 
heating purposes, in accordance with their technical features.

• 

Any contractual or extra-contractual liability of the Company is 
excluded for injury/damage to persons, animals or objects owing 
to installation, regulation and maintenance errors or improper 
use. All uses not expressly indicated in this manual are prohibited.

• 

Use suitable Personal Protective Equipment (PPE) during 
installation, maintenance, and cleaning stages.

• 

Do not use the unit as storage for equipment or spare parts. Any 
use other than that indicated in this manual is prohibited as it can 
generate dangerous situations.

• 

ATTENTION: the electric and hydraulic connections, together 
with installation of the fan coils and their accessories must 
only be performed by technicians who have the technical-
professional requisites for installation, transformation, extension 
and maintenance of the systems and who can verify these 
functions in terms of safety and functionality (in accordance with 
the national laws in force in the country of installation). In this 
manual they will be also identified as: experienced and qualified 
technician with specific technical knowledge.

• 

Aermec will not be liable for damage due to failure to follow these 
instructions.

• 

Make sure the unit has not been damaged during transport 
before installation. 

• 

using a damaged machine could be dangerous.

• 

the support surface must withstand the weight of the unit.

• Note:
• 

Always indicate the serial number for future reference 
and for any communication with AERMEC S.p.A.

• STORING 

THE 

DOCUMENTATION

• 

Hand over the instructions with all the related documenta-
tion to the system user, who must store the instructions so 
that they are always available in case of necessity.

TRANSPORT

• 

Refer to the weight indications on the data plate to transport the 
unit safely.

• 

Take the following measures during transport: 

• 

The unit and the accessories must not undergo violent impacts in 
order not to affect the integrity of the structure and of the internal 
components;

• 

during transportation, the unit and any accessories must be 
protected in order to prevent impacts, for this reason they must 
be properly secured on the transportation floor with ropes or any 
other means that prevent their movement;

• 

during transport and storage, the unit and the accessories must 

always be protected against bad weather.

VERIFICATIONS UPON RECEPTION

• 

Visually check the unit upon reception to make sure that:

• 

the order corresponds with what is indicated in the transport 
documents;

• 

packaging is intact;

• 

the unit is intact;

• 

all the components have been provided.

• 

Indicate any damage or missing components on the transport 

document. 

Summary of Contents for FCZ P

Page 1: ...E INSTALLAZIONE USE AND INSTALLATION MANUAL MANUEL D UTILISATION ET D INSTALLATION B E D I E N U N G S U N D I N S T A L L A T I O N S A N L E I T U N G MANUAL DE INSTRUCCIONES E INSTALACI N IT EN FR...

Page 2: ...faut pr voir l espace n cessaire pour les op rations d entretien et ou de r paration La garantie de l appareil ne couvre pas les co ts d rivant de l utilisation de voitures avec chelle m canique d cha...

Page 3: ...ibung des produkts 20 Wichtige hinweise und wartung 20 Verpackung 20 Installation der einheit 21 Elektrische anschl sse 21 Drehen der batterie 21 Advertencias generales 22 Descripci n del producto 24...

Page 4: ...wenn sein Gewicht die 25kg bersteigt NO transportar la m quina solos si su peso es superior a los 25Kg NON lasciare gli imballi sciolti durante il trasporto Non rovesciare DO NOT leave boxes unsecure...

Page 5: ...rieur de l unit et reporte les donn es d identification et les caract ristiques techniques du produit ATTENTION L alt ration l enl vement l absence de la plaque d identification ou de tout autre l men...

Page 6: ...r the electric power supply use integral cables with suitable section for the load Do not introduce objects into air vents Do not introduce any objects into the air outlet slots This could cause injur...

Page 7: ...r necessary knowledge as long as they are supervised or have been instructed on the safe use Of the appliance and on the understanding of the dangers inherent to it Children must not play with the app...

Page 8: ...n the aircouldsoilthesurfaceofthecoil IT IS NORMAL Duringcooling watervapourmaybepresentintheairdeliveryofthefancoil In the heating function it might be possible to hear a slight hiss around the fan c...

Page 9: ...connections all the trays are arranged for the condensate discharge on both sides Slide out the electrical connections from the right side remove the push and move the cable guide g from right to lef...

Page 10: ...Temperatur und Feuchtigkeitswerte siehe Abschnitt DURCHSCHNITTLICHE MINDEST WASSERTEMPERATUR Se han alcanzado las condiciones l mites de temperatura y humedad descritas en M NIMA TEMPERATURA MEDIA DE...

Reviews: