3.8.6
Active Flags
ID:
COOLMAX SR Base A 5
Variable
Bits
Type
Description
Unused
63…13
-
-
Panel missing
12
Boolean
Input voltage indicates panel missing
Log file full
11
Boolean
Log file full
Maximizer fault
10
Boolean
Regulation or power stage fault
Bat temp sensor fault
9
Boolean
Battery temperature sensor fault
Not used
8
Boolean
-
Not used
7
Boolean
-
Hi bat temp
6
Boolean
High battery temp fault
Bat current
5
Boolean
High battery discharge current fault
Iout fault
4
Boolean
High output current fault
Vout high fault
3
Boolean
High output voltage fault
Not used
2
-
-
Vout low fault
1
Boolean
Low output voltage fault
Vout low warning
0
Boolean
Low output voltage warning
3.8.7
Time
ID:
COOLMAX SR Base A 7
Variable
Bits
Type
Description
Time
63…0
Uint64
System Unix time
3.9
COOLMAX SR COMMAND MESSAGES
3.9.1
Reset Command
ID:
Driver Controls Base A 23
Variable
Bits
Units
Description
Unused
63…32
Unit32
-
Reset command string
ALL – full reset
RCO – remote config reset
31…0
Uint32
Send 'ALL' or 'RCO' as a string (“00000ALL”)
COOLMAX SR replies with Y or N in byte 0