INSTRUCTION MANUAL 
 

Air dehumidifier 

 

 

Series 

AD810-P 

 

 

 

 
 

 

 

 

 

 

 

Summary of Contents for BlueDry AD810-P Series

Page 1: ...MADE IN GERMANY INSTRUCTION MANUAL Air dehumidifier Series AD810 P...

Page 2: ...hts reserved The instruction manual is based on the technical and product specific parameters The manufacturer reserves the right to add supplementary information to the instruction manual Any use of...

Page 3: ...11 Electrical connection ______________________________________________________12 Connect condensate drain hose___________________________________________13 Connection of the optional dewpoint kit ___...

Page 4: ...nts for proper and safety conscious handling of the dehumidifiers must always be met Conventions In this instruction manual you will find notes preceding the operating steps described to warn you of p...

Page 5: ...ons set out in this manual Hazards from accessories Waste water hoses and air filters must be properly installed and must not disable the protection devices of the condensation dryers The operating el...

Page 6: ...increased lime deposits in rooms with salt or liquids with a salt content 1 incl brine baths in rooms with ozone treated air in rooms with high solvent concentration in rooms with extreme dust load Pl...

Page 7: ...ifiers within the limits of designated use also involves observing the specified operating conditions refer to page 11 Any use of the air dehumidifier not in conformity with or going beyond the design...

Page 8: ...tion The air dehumidifier is equipped with two lateral handles two guide pulleys and two transport rollers Fig 1 AD810 P series air dehumidifier isometric view 1 Front wall air outlet 3 Carrying handl...

Page 9: ...Page 7 of 27 Fig 2 Series AD810 P air dehumidifier rear view 1 Filter holder 4 Pushbutton for manual draining 2 Air intake area with air filter 5 Amphenol can for dewpoint kit 3 Power cable 6 Condens...

Page 10: ...Room sensor AD810 P has been fitted with condensate drain pump with which the condensate water is drained The pump has a maximum head of 4 m To close the condensate water hose please use the quick co...

Page 11: ...into the openings at the front or rear Lift the device with a colleague and use suitable lifting and transport equipment CAUTION Material damage Pulling the power cable may damage the cable Always di...

Page 12: ...ifting and transport equipment In case of wall mounting use suitable holders and fastening elements according to the weight 1 Report any obvious damage to the carrier parcel service postal service etc...

Page 13: ...res is inefficient and can result in icing Storage of the air dehumidifier at impermissible temperature conditions can result in damage problems in case of immediate switching on In case of storage be...

Page 14: ...s must be checked prior to electrical connection of the air dehumidifier The mains voltage must be in conformity with the voltage of the air dehumidifier Socket outlet and supply system must be suffic...

Page 15: ...the hose Do not place any objects on the hose Check regularly whether condensate is properly discharged 1 Attach the condensate drain hose to the quick coupling Fig 4 page 8 and secure with a hose cl...

Page 16: ...tute a risk Read the instruction manual before commissioning the air dehumidifier Operating elements AD810 P Fig 5 Operating panel AD810 P 1 Current room humidity 6 Stepwise fan setting 2 Target room...

Page 17: ...ty is higher than the set humidity value the air dehumidifier will start to work The last values for hygrostat language and fan step are taken over where applicable Operator control Use the arrow keys...

Page 18: ...fter the room humidity has reached the value set and the sensor measures thawing For living space climate conditions of 20 25 C and 55 65 r h are recommended For quick building drying the hygrostat is...

Page 19: ...and service WARNING Danger of injury due to contact with hot components inside the air dehumidifier Work on inside components may only be carried out by the manufacturer or personnel authorised by th...

Page 20: ...t only trained expert staff with inspection and any work inside the air dehumidifier Work on electrical parts of the air dehumidifier may only be carried out by the manufacturer or by authorised quali...

Page 21: ...er regularly In order to guarantee trouble free functioning of the air dehumidifier also in continuous operation the air dehumidifier in particular the air filter must be checked and cleaned at regula...

Page 22: ...cturer Any work carried out by unauthorized persons shall lead to the forfeiture of all warranty claims WARNING Danger of injury due to contact with hot components inside the air dehumidifier Work on...

Page 23: ...C or 35 deg C The unit will start up automatically when the temperature is 5 deg C or 30 deg C again Faults Problem Possible cause Remedy Air dehumidifier shows poor or no humidification performance...

Page 24: ...t of operation the compressor is working The air dehumidifier is in defrost mode The compressor continues to run not however the fan After a few minutes the fan will automatically start again The air...

Page 25: ...r is immediately switched on after storage in colder environments The humidity set on the hygrostat is not achieved or the air dehumidifier does not automatically switch off Hygrostat set to a value 4...

Page 26: ...the on off button to switch the air dehumidifier on 3 Pull the power plug 4 If necessary cover the air dehumidifier with a cloth to protect it from dust Storage To store a single air dehumidifier we...

Page 27: ...n class IP X4 Protection for indoor swimming pools RCCB to be installed by user Operating conditions 1 C to 34 C 35 r h to 95 r h Type Unit AD810 P Air circulation rate Fan speed I cbm h 1000 Fan spee...

Page 28: ...ssure in closed indoor rooms The air dehumidifier can prevent the formation of condensation water remove excessive humidity and keep humidity at a defined constant level The air dehumidifier is design...

Page 29: ...Particular requirements for electrical heat pumps air conditioners and dehumidifiers EN 60204 1 2006 A1 2009 Safety of machinery Electrical equipment of machines Part 1 General requirements EN ISO 13...