background image

DH8500EW
DH9500EW

GB

DE

FR

NL

Dehumidifier

Luftentfeuchter

Déshumidificateur

Ontvochtiger

www.ecor-pro.com

ES

Deshumidificador

Summary of Contents for DH8500EW

Page 1: ...DH8500EW DH9500EW GB DE FR NL Dehumidifier Luftentfeuchter Déshumidificateur Ontvochtiger www ecor pro com ES Deshumidificador ...

Page 2: ...safe place for future reference Before using your dehumidifier for the first time please ensure that it has been standing for 2 hours in it s upright position before it is switched on SAFETY For safety reasons read this information carefully before operating Persons who are not familiar with this type of product must not use it This appliance must be earthed and should only be connected to an eart...

Page 3: ...al cable and an earthed plug Should it be necessary to replace this plug at any time you must use an earthed electrical plug Warning Never operate this appliance if it has a damaged cord or plug If the supply cord is damaged it must be replaced by an approved service repre sentative or a similar qualified person in order to avoid any hazards There should be direct access to the electrical plug aft...

Page 4: ...This condensate water then flows safely into a fixed drain The dried air then passes through a final heat exchanger where it is warmed before it re enters the room area at a slightly elevated temperature The level of dehumidifying is set with the digital humidistat control Moist Air Warm Dry Air Cooled Heat Exchanger Warmed Heat Exchanger Compressor Inlet Grille Air Filter Fan Drain ...

Page 5: ... of excess mois ture as soon as it is plugged in and switched on When positioning your Ecor Pro dehumidifier ensure that it is placed on a level surface Best results are obtained when windows and doors are closed thus prevent ing the possible influx of more humid air When the unit is placed in a swimming pool area connect to the mains via a transformer or a breaking switch conform the local regula...

Page 6: ...e supporting bracket with at least 5 screws horizontally to the wall use the appropriate fixings for the type of wall Note the unit is heavy approxi mately 25kg Hang the unit on the bracket the two tongues fit into the slots on the unit s rear panel Make sure the three rubber support pads on the lower part of the rear panel are properly placed ...

Page 7: ...ting it back and closing the grille Housing Wipe regularly clean with a moist cloth and mild household detergent Servicing Have your dehumidifier once a year serv iced by a qualified engineer Caution This unit should not be operated without the air filter fitted Operation without the air filter may damage the heat exchanger DRAINAGE Connecting the permanent outlet Connect the pipe to an outlet tub...

Page 8: ...l stop however the fan will continue to run for approximately 15 minutes this will clear the heat exchanger of all collected water Fan speed Press the FAN SPEED SELECT button to select low or high speed The cor responding control light will indicate this Lo low or Hi high Humidity Temperature display The digital display will normally show the measured relative humidity in the area Your Ecor Pro de...

Page 9: ...n temperatures below 7 C or above 35 C Defrost Control The dehumidifier is equipped with an automatic de icing mode to defrost the refrigeration coil during low temperature operation The compressor is switched off whilst the fan continues to run GB TROUBLE SHOOTING If the dehumidifier does not operate Make sure the unit is plugged in Ensure the humidistat control is turned on If the unit is noisy ...

Page 10: ... C Condensate pump head Option 1 8m 1 8m Refrigerant R410A Hermetically sealed EC No 842 2006 R410A is a preparation of fluorinated greenhouse gases covered by the Kyoto Protocol Its global warming potential GWP is 1725 Disposal This marking indicates that this product should not be disposed with other house hold wastes throughout the EU To prevent possible harm to the environment or human health ...