background image

page 10 of 13 

 
 
 

Capacity / power consumption at 

30°C / 80% 

l/24h 

Watt 

8,5 

198 

27°C / 60% 

l/24h 

Watt 

4,4 

182 

20°C / 60% 

l/24h 

Watt 

2,7 

160 

10°C / 70% 

l/24h 

Watt 

1,7 

142 

dimensions 

mm 

494 x 330 x 241 

weight 

kg 

24 

 

8. Service & Maintenance 

 
ATTENTION! 

When performing any repair or maintenance, the general safety rules and 
provisions must be adhered to! 

 
 

To the protection of a troublefree function, the device should be cleaned regularly. 
The following procedure is recommended: 
 

  Switch OFF the air dryer 
  Disconnect mains cable 
  Remove filter for cleaning or disposal 

During strong pollution:  

  Dismantle cover and top 
  Blow out device cautiously with compressed air. (wear protective goggles!)  In 

this case, it might ensure that all components are cleaned. (Compressor, 
evaporator, condenser, ect.) 

  Visual inspection: Drain and connected hose 

 

  Clean case with moist cloth. Do not use aggressive Detergent 
  Mount cover and top 
  Insert new or cleaned filter 
  Put main plug into the sucket 
  Switch on dehumidifier 

 

This cleaning is without fail regularly required! 

No other maintenance work is required for the air dryer

 
 
 
 
 

Summary of Contents for AD 110

Page 1: ...page 1 of 13 Instruction manual _____________________________________ Dehumidifier AD 110 _____________________________________ valid 02 2012...

Page 2: ...ical connection 6 5 2 Putting into operation 6 5 3 Operation panel 7 5 4 Hygrostat control 7 8 5 5 Condensate outlet 8 5 6 Automatic defrosting 8 6 Operating conditions 8 9 7 Technical data 9 10 8 Ser...

Page 3: ...order to be able to send the device safe for guarantee repair In order to save place you open simply the adhesive tape with a knife and you fold the carton 2 Mode of operation The AD air dryer is cons...

Page 4: ...Using as directed The condensation dryers are intended for the drying of air with atmospheric pressure Risk by accessory Hoses for condensate removal and air filters must be fit expertly and must not...

Page 5: ...and the air filter must at least conduct 1 meter The open space under that dehumidifier must conduct at least 10 cm That dehumidifier is attached with the delivered mounting bar to a wall Rough draft...

Page 6: ...of time the oil distributed inside the refrigerating system and frothed during transport will return into the compressor We recommend this procedure since it extends the service life of the compressor...

Page 7: ...midity is higher than 80 60 The dehumidifier switches off when a humidity of approx 60 r h has achieved And switches on again when humidity is higher than 60 40 The dehumidifier switches off when a hu...

Page 8: ...ding on the extent of ice formation the appliance will be defrosted automatically according to the following principle A temperature sensor measures the condition existing in a critical area of the ev...

Page 9: ...hat extremely air movings around the dryer can annoy or affect the function of the dryer as the air flow of the dryer can not flow as planned In the case of doubtful operating conditions it is recomme...

Page 10: ...ure is recommended Switch OFF the air dryer Disconnect mains cable Remove filter for cleaning or disposal During strong pollution Dismantle cover and top Blow out device cautiously with compressed air...

Page 11: ...h voltage Check the main cable an additional cable the socket and the main fuse The at the hygrostat adjusted value has been achieved The dryer will start again after exceeding the adjusted humidity 4...

Page 12: ...ng defects and malfunctions of AERIAL air dryers we recommend to get in touch with your supplier 10 Disposal Please do not dispose this unit with the domestic waste and please do not dispose this unit...

Page 13: ...ready for connection Related standards EN ISO 12100 Safety of Machinery EN 61000 Electromagnetic Compatibility EMC Basic Specification Emitted Interference EN 60335 2 40 Safety of electric appliances...