7
BASIC
The fan runs continuously at selected trickle speed (set by the jumper switch combination
fig. 15) and can be boosted with a dedicated ON/OFF switch (or PIR, CO2…sensor) or
with a light switch (fig. 13A). Trickle speed can be set to off (fig. 15).
WITH HUMIDISTAT/TIMER
The fan is equipped with a humidity sensor, whose threshold is adjustable from 50%
Quantum AX is a decentralised mechanical ventilation unit designed to ensure air
extraction in small/medium-sized rooms.
Suitable for air discharge directly to the outside or in the presence of short ducted
system. Wall, ceiling or window installation (fig. 1).
• Material: High quality, impact and UV-resistant ABS colour RAL 9010.
• Design front cover removable for cleaning without the use of tools.
• Rear reinforcement ring to prevent spigot deformation during installation.
• High efficiency aerodynamic fan with “winglet” blades to optimise quietness and
efficiency.
• Single phase EC Brushless motor with integral thermal protection.
• Motor mounted on high quality ball bearings.
• The fan is double insulated: no earth connection is required.
• Trickle speed selectable during installation.
• Option to boost from trickle (or from off) through LS connection.
• Installation type selection available (through wall or ducted).
• Timer and Integral Humidistat versions available.
• IPX4 degree of protection.
• Power supply 220-240V~ 50Hz.
equipment operation.
• Install the product so that the impeller is not accessible from the air outlet side as
verified by contact with the Test Finger (test probe “B” of the norm EN61032) in
compliance with the current safety regulations.
• Ceiling installation
In order to guarantee the IPX4 degree of protection against moisture in case of
ceiling installation, use the appropriate ceiling mount kit, which is not included. Use
only the rear entry hole for supply cables. If there is a possibility of condensation
along the air discharge duct, provide a drainage system to prevent condensation
from discharging into the environment through the fan.
Attention: do not mount the product on the ceiling without this kit.
• Window installation
In case of window installation it is necessary to use the appropriate window kit,
which is not included.
Attention: do not mount the product on the window without this kit.
introduction
tecHnicAl sPeciFicAtions
Versions
Model
Airflow
m
3
/h
Power
W max
sound pressure
dB(A) @3m
Quantum AX 100
max 83
min from 27 to 62
max 2,6
min from 1 to 1,7
max 26
min from 11 to 23
Quantum AX 150
max 187
min from 29 to 98
max 6,5
min from 1 to 2
max 35
min from < 9 to 18