BC 2000 DIGITAL
Audio Routing, Mixing and Processing System for Program Production Centres
.
ARENA DM CONTROL SURFACE
FUNCTIONAL DESCRIPTION
19
3.1.3.1.2. Saving and loading compressor settings.
When “Preset List” is selected, the following screen is displayed:
An item from the list can be selected using the navigation cursors (5),
and then one of the two available options can be chosen: “Save” or
“Load.” The option chosen is validated using the middle button, or the
screen is exited if “EXIT” has been selected.
The “Load”
option loads the
respective effect
in the list of 4
presets that are
displayed when
the compressor
is accessed.
"Save” lets you
save the
parameter
changes made
in a certain
preset.
3.1.3.2. Noise Gate.
To enter the menu for the Noise Gate effect, press the navigator’s OK key (5)
over the Noise Gate
option on the screen
that is displayed in
section 3.1.3. (page
14). The menus
displayed for this effect
work in exactly the
same way as the ones
for the compressor /
limiter, except for
setting the parameters,
which are the following:
Threshold.
Attack time.
Release time.
Hold time.
Range.
When establishing the settings, the threshold for the noise gate will be much
lower than in the case of the compressor, as its operation is the opposite. The
noise gate prevents the passage of the lower levels of the signal that could be
considered noise. Therefore, the range of settings is different.
In addition, there is an additional parameter for noise gates, which is “Hold
Time”. This is a safety period used to prevent the gate from accidentally closing
if a signal is suddenly absent, for example, in speech.