![AEQ AM-04 User Manual Download Page 9](http://html1.mh-extra.com/html/aeq/am-04/am-04_user-manual_2861323009.webp)
AEQ AM-04
Analog, AES/EBU and SDI embedded Audio Monitor with Alarm System
9
3.3. BARGRAPHS SCALES
The following bargraph ballistics may be selected using internal switches.
SCALE TYPE
RANGE
ATTTACK
TIME
FALLBACK
AES/EBU:
60 dB (0 to -60 dB)
1 ms
1,5 s per 20 dB decay
DIN PPM:
55 dB (+50 to-50 dB)
10 ms
1,5 s per 20 dB decay
VU:
23 dB (+3 to -20 dB)
300 ms
300 ms
BBC PPM:
+12 a –12 dB – mark 7 to 1
10 ms
2,85 s - mark 7 to 1
VU EXT:
80 dB (+20 to -60 dB)
300 ms
300 ms
NORDIC:
54 dB (+12 to -42 dB)
5 ms
1,7 s per 20 dB decay
AM – 04 scales ballistics
Stick-on scale graticules,
which may be applied to the space between the front-panel
bargraphs, are supplied with the unit.
AM – 04 scale graticules
Note:
Bargraph color transition points and peak hold decay may also be adjusted internally.
Refer to the Configuration chapter for switch settings and graticule fitting instructions.