5.2. ADJUSTING ANALOG OUTPUT LEVEL
In the following tables, ON is obtained with a switch lever in the DOWN position. The
adjustments are located on the SD sub-board at the rear of the unit.
Analog out adjustments. 0dB setting shown
SW1
Anlg
Output
Setting when ON
SW2
Anlg
Output
Setting when ON
1
1
0 dB (0 on analog scale =
0dBu on output)
1
3
0 dB (0 on analog scale =
0dBu on output)
2
1
4 dB (0 on analog scale =
+4dBu on output)
2
3
4 dB (0 on analog scale =
+4dBu on output)
3
1
8 dB(0 on analog scale =
+8dBu on output)
3
3
8 dB(0 on analog scale =
+8dBu on output)
4
1
Variable. adjacent pot RV1*
0 to +12 Db
4
3
Variable. adjacent pot
RV3* 0 to +12 Db
5
2
0 dB (0 on analog scale =
0dBu on output)
5
4
0 dB (0 on analog scale =
0dBu on output)
6
2
4 dB (0 on analog scale =
+4dBu on output)
6
4
4 dB (0 on analog scale =
+4dBu on output)
7
2
8 dB(0 on analog scale =
+8dBu on output)
7
4
8 dB(0 on analog scale =
+8dBu on output)
8
2
Variable. adjacent pot RV2*
0 to +12 dB
8
4
Variable. adjacent pot
RV4* 0 to +12 dB
Note:
It is intended that only one switch lever is set ON for each analog output. The ON
position is obtained with a switch lever in the direction of the arrow (downward in the above
drawing).
*Clockwise rotation increases gain.