Association Groups: 

Group Number 

Maximum 
Nodes 

Description 

Z-Wave Plus Lifeline.When the load state of Nano Switch (on/off) is changed, the 
Hail CC, Switch Multilevel Report and Basic Report (configured by parameter 80) 
can be sent to the associated nodes in this group. 

Forward the Basic Set, Switch All, Scene Activation Set to associated nodes in 
Group 2 when the Nano Switch receives the Basic Set, Switch All, Scene Activation 
Set commands from main controller. 

Send Basic Set (configured by parameter 82) to the associated nodes in Group 3 
when the external switch S1 is operated 

Send Basic Set (configured by parameter 82) to the associated nodes in Group 4 
when the external switch S2 is operated 

Configuration Parameters 

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt 
the function better to user needs or unlock further enhanced features. 

IMPORTANT:

 Controllers may only allow configuring signed values. In order to set values in the range 128 ... 

255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 
200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic 
applies: Values greater than 32768 may needed to be given as negative values too. 

Parameter 3: Current Overload Protection. 

Over current protection. Output load will be closed after 30 seconds if the current exceeds (US: 15.5A, AU or 
EU: 10.5A)

 

Size: 1 Byte, Default Value: 1 

Setting 

Description 

Disable 

Enable 

Parameter 4: Overheat protection. 

Output Load will be turned off automatically after 30 seconds and if the temperature of product inside exceeds 
100°C.

 

Size: 1 Byte, Default Value: 0 

Setting 

Description 

Disable 

Enable 

Parameter 20: Configure the output status after re-power on it. 

Configure the output status after re-power on it.

 

Size: 1 Byte, Default Value: 0 

Setting 

Description 

Last status 

Always on 

Always off 

 

 

Summary of Contents for ZW116

Page 1: ...resulting from failure to comply with the instructions in this manual or any other material Use this equipment only for its intended purpose Follow the disposal instructions Do not dispose of electron...

Page 2: ...s to control the load ON OFF independently Its surface has a pin socket which can be used for connecting to the touch panel so you can also use the touch panel to control the Nano Switch The Nano Swit...

Page 3: ...load 1 S2 External switch control for load 2 1 Shut off the main circuit breaker of your home for safety during the installation and ensure the wires are not short circuited during the installation w...

Page 4: ...the following diagram to achieve this Note The IN terminal should be connected to the of DC 24V input Wiring diagram of DC24V power input Since the Nano Switch also supports the DC24V power input so y...

Page 5: ...ions 2 Press the button 2 times quickly on the Nano Switch Exclusion 1 Press the button once on the Dual Nano Switch Quick trouble shooting Here are a few hints for network installation if things dont...

Page 6: ...or unlock further enhanced features IMPORTANT Controllers may only allow configuring signed values In order to set values in the range 128 255 the value sent in the application shall be the desired v...

Page 7: ...Value 1 Setting Description 0 Send Nothing 1 Send Basic Set CC Parameter 82 To set which notification would be sent to the associated nodes in association group 4 To set which notification would be se...

Page 8: ...value Mon to Sun 16777215 Disable the setting 16777216 Enable the setting Parameter 90 Enables disables parameter 91 and 92 below Enables disables the function of parameter 91 and 92 Size 1 Byte Defau...

Page 9: ...n Report group 2 To set which reports need to be sent in Report group 2 Size 1 Byte Default Value 0 Setting Description 1 Send Meter Report of voltage V 2 Send Meter Report of current A 4 Send Meter R...

Page 10: ...2147483647 The range of interval time is 1 to 2147483647 Parameter 120 Configure the external switch mode for S1 Configure the external switch mode for S1 Size 1 Byte Default Value 0 Setting Descripti...

Page 11: ...ing and removed from the z wave network Technical Data Dimensions 0 0425000x0 0400000x0 0200000 mm Weight 28 5 gr Hardware Platform ZM5202 EAN 1220000015333 IP Class IP 20 Voltage 24V DC 230V AC Load...

Page 12: ...ves can be sensors actuators and even remote controls Primary Controller is the central organizer of the network It must be a controller There can be only one primary controller in a Z Wave network In...

Reviews: