Parameter 252: Lock/unlock configuration parameters 

Lock/unlock configuration parameters.

 

Size: 1 Byte, Default Value: 0 

Setting 

Description 

Unlock 

Lock 

Parameter 255: Reset the Nano Dimmer 

Reset the Nano Dimmer to factory default.

 

Size: 4 Byte, Default Value: 0 

Setting 

Description 

Reset all configuration parameters to factory default setting 

1431655765 

Reset to factory default setting and removed from the z-wave network 

Technical Data 

Dimensions 

0.0425000x0.0400000x0.0200000 mm 

Weight 

28.5 gr 

Hardware Platform 

ZM5202 

EAN 

1220000015333 

IP Class 

IP 20 

Voltage 

24V DC/ 230V AC 

Load 

6,5 A 

Device Type 

On/Off Power Switch 

Generic Device Class 

Binary Switch 

Specific Device Class 

Binary Power Switch 

Firmware Version 

01.00 

Z-Wave Version 

04.22 

Certification ID 

ZC10-17035496 

Z-Wave Product Id 

0x0086.0x0003.0x0074 

Frequency 

Europe - 868,4 Mhz 

Maximum transmission power 

5 mW 

Supported Command Classes 

 

Basic 

 

Switch Binary 

 

Switch All 

 

Scene Activation 

 

Scene Actuator Conf 

Summary of Contents for ZW116

Page 1: ...resulting from failure to comply with the instructions in this manual or any other material Use this equipment only for its intended purpose Follow the disposal instructions Do not dispose of electron...

Page 2: ...s to control the load ON OFF independently Its surface has a pin socket which can be used for connecting to the touch panel so you can also use the touch panel to control the Nano Switch The Nano Swit...

Page 3: ...load 1 S2 External switch control for load 2 1 Shut off the main circuit breaker of your home for safety during the installation and ensure the wires are not short circuited during the installation w...

Page 4: ...the following diagram to achieve this Note The IN terminal should be connected to the of DC 24V input Wiring diagram of DC24V power input Since the Nano Switch also supports the DC24V power input so y...

Page 5: ...ions 2 Press the button 2 times quickly on the Nano Switch Exclusion 1 Press the button once on the Dual Nano Switch Quick trouble shooting Here are a few hints for network installation if things dont...

Page 6: ...or unlock further enhanced features IMPORTANT Controllers may only allow configuring signed values In order to set values in the range 128 255 the value sent in the application shall be the desired v...

Page 7: ...Value 1 Setting Description 0 Send Nothing 1 Send Basic Set CC Parameter 82 To set which notification would be sent to the associated nodes in association group 4 To set which notification would be se...

Page 8: ...value Mon to Sun 16777215 Disable the setting 16777216 Enable the setting Parameter 90 Enables disables parameter 91 and 92 below Enables disables the function of parameter 91 and 92 Size 1 Byte Defau...

Page 9: ...n Report group 2 To set which reports need to be sent in Report group 2 Size 1 Byte Default Value 0 Setting Description 1 Send Meter Report of voltage V 2 Send Meter Report of current A 4 Send Meter R...

Page 10: ...2147483647 The range of interval time is 1 to 2147483647 Parameter 120 Configure the external switch mode for S1 Configure the external switch mode for S1 Size 1 Byte Default Value 0 Setting Descripti...

Page 11: ...ing and removed from the z wave network Technical Data Dimensions 0 0425000x0 0400000x0 0200000 mm Weight 28 5 gr Hardware Platform ZM5202 EAN 1220000015333 IP Class IP 20 Voltage 24V DC 230V AC Load...

Page 12: ...ves can be sensors actuators and even remote controls Primary Controller is the central organizer of the network It must be a controller There can be only one primary controller in a Z Wave network In...

Reviews: