certified Z-Wave device regardless of brand and origin 

as long as both are suited for the same frequency 

range. 

If a device supports 

secure communication

 it will communicate with other devices secure as long as this device 

provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to 
maintain backward compatibility. 

For more information about Z-Wave technology, devices, white papers etc. please refer to 

www.z-wave.info

. 

Product Description 

Aeotec  Nano Switch is a low-cost Z-Wave Switch specifically used to enable Z-Wave command and control 
(on/off) of any wall switches. It can report immediate wattage consumption or kWh energy usage over a period 
of time. In the event of power failure, non-volatile memory retains all programmed information relating to the 
unit?s operating status. 
 
It can connect to 2 external manual switches to control the load ON/OFF independently. Its surface has a pin 
socket, which can be used for connecting to the touch panel, so you can also use the touch panel to control the 
Nano Switch.  
 
The Nano Switch is also a security Z-Wave device and supports Over The Air (OTA) feature for the products 
firmware upgrade. 
 

 

Prepare for Installation / Reset 

Please read the user manual before installing the product. 

In order to include (add) a Z-Wave device to a network it 

must be in factory default state.

 Please make sure to 

reset the device into factory default. You can do this by performing an Exclusion operation as described below in 
the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the 
primary controller of the previous network to make sure the very device is excluded properly from this network. 

Reset to factory default 

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only 
be used when the primary controller is inoperable. 

Set Parameter 255 

Safety Warning for Mains Powered Devices 

Summary of Contents for ZW116

Page 1: ...resulting from failure to comply with the instructions in this manual or any other material Use this equipment only for its intended purpose Follow the disposal instructions Do not dispose of electron...

Page 2: ...s to control the load ON OFF independently Its surface has a pin socket which can be used for connecting to the touch panel so you can also use the touch panel to control the Nano Switch The Nano Swit...

Page 3: ...load 1 S2 External switch control for load 2 1 Shut off the main circuit breaker of your home for safety during the installation and ensure the wires are not short circuited during the installation w...

Page 4: ...the following diagram to achieve this Note The IN terminal should be connected to the of DC 24V input Wiring diagram of DC24V power input Since the Nano Switch also supports the DC24V power input so y...

Page 5: ...ions 2 Press the button 2 times quickly on the Nano Switch Exclusion 1 Press the button once on the Dual Nano Switch Quick trouble shooting Here are a few hints for network installation if things dont...

Page 6: ...or unlock further enhanced features IMPORTANT Controllers may only allow configuring signed values In order to set values in the range 128 255 the value sent in the application shall be the desired v...

Page 7: ...Value 1 Setting Description 0 Send Nothing 1 Send Basic Set CC Parameter 82 To set which notification would be sent to the associated nodes in association group 4 To set which notification would be se...

Page 8: ...value Mon to Sun 16777215 Disable the setting 16777216 Enable the setting Parameter 90 Enables disables parameter 91 and 92 below Enables disables the function of parameter 91 and 92 Size 1 Byte Defau...

Page 9: ...n Report group 2 To set which reports need to be sent in Report group 2 Size 1 Byte Default Value 0 Setting Description 1 Send Meter Report of voltage V 2 Send Meter Report of current A 4 Send Meter R...

Page 10: ...2147483647 The range of interval time is 1 to 2147483647 Parameter 120 Configure the external switch mode for S1 Configure the external switch mode for S1 Size 1 Byte Default Value 0 Setting Descripti...

Page 11: ...ing and removed from the z wave network Technical Data Dimensions 0 0425000x0 0400000x0 0200000 mm Weight 28 5 gr Hardware Platform ZM5202 EAN 1220000015333 IP Class IP 20 Voltage 24V DC 230V AC Load...

Page 12: ...ves can be sensors actuators and even remote controls Primary Controller is the central organizer of the network It must be a controller There can be only one primary controller in a Z Wave network In...

Reviews: