BATTERY CHARGING

NanoMote Quad has an internal rechargeable battery that will run for three months under the normal use condition. The charger

s output should be a micro 

terminal with the specification of output DC 5V.The LED color is red during the charging process, and it will turn to green if the charging is finished.

Communication to a Sleeping device (Wakeup)

This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In orde
communicate with the device, a static controller 

C

 is needed in the network. This controller will maintain a mailbox for the battery operated devices and store

commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time 
significantly decreased.

This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbo
Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static contro
controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses o
device. To wakeup the device please perform the following action: Pressing and holding a button for 3 seconds. Led will turn to green,which means Scene C
has been woken up.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

1.  Make sure a device is in factory reset state before including. In doubt exclude before include.
2.  If inclusion still fails, check if both devices use the same frequency.
3.  Remove all dead devices from associations. Otherwise you will see severe delays.
4.  Never use sleeping battery devices without a central controller.
5.  Dont poll FLIRS devices.
6.  Make sure to have enough mains powered device to benefit from the meshing

Firmware-Update over the Air

This device is capable of receiving a new firmware 'over the air'. The update function needs to be supported by the central controller. Once the controller sta
update process, perform the following action to confirm the firmware update: With reference to Wake-up operation (VI.WAKE UP) and Z-Wave controller

s g

do OTA.

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a dif
device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they a
related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will rece
same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number

Maximum
Nodes

Description

1

5

NanoMote Quad will send the central scene notification command and battery report comma
associated nodes if any button is triggered.

2

5

NanoMote Quad will send Basic Set command to the associated nodes if button 1 is presse

3

5

NanoMote Quad will send switch multilevel set, the multilevel start level change and multileve
level change command to the associated nodes if button 1 is pressed, hold and released, re

4

5

NanoMote Quad will send Basic Set command to the associated nodes if button 2 is presse

5

5

NanoMote Quad will sendswitch multilevel set, the multilevel start level change and multileve
level change command to the associated nodes if button 2 is pressed, hold and released, re

6

5

NanoMote Quad will send Basic Set command to the associated nodes if button 3 is presse

7

5

NanoMote Quad will sendswitch multilevel set, the multilevel start level change and multileve
level change command to the associated nodes if button 3 is pressed, hold and released, re

8

5

NanoMote Quad will send Basic Set command to the associated nodes if button 4 is presse

9

5

NanoMote Quad will sendswitch multilevel set, the multilevel start level change and multileve
level change command to the associated nodes if button 4 is pressed, hold and released, re

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock fu
enhanced features.