background image

Refer to section "Parameter Configurations"

Parameter 1 will determine what mode the Door / Window Sensor 7 is used as.

Communication test.

This utilizes the Power Level command class to determine the health between the Door / Window Sensor 7 and your

Z-Wave gateway. This will tell you if the Door / Window Sensor 7 has a healthy connection to your system and is a great

method of debugging connectivity issues.

1. 

Set Parameter #5 to value #1

2. 

Double click the Tamper Switch.

3. 

Result:

Blinks once - success

Blinks 3x times - failure

Scene Controller.

When activated by configuration parameter #14 the device can perform as a scene controller. The external dry contact will

then act as a scene controller with a total of 7 scenes that can be activated:

1. 

Contact Pressed 1 time

2. 

Contact Pressed 2 time

3. 

Contact Pressed 3 time

4. 

Contact Pressed 4 time

5. 

Contact Pressed 5 time

6. 

Contact held down

7. 

Contact released

Firmware-Update over the Air.

This device is capable of receiving a new firmware 'over the air'. The update function needs to be supported by the central

controller. Once the controller starts the update process, perform the following action to confirm the firmware update:

1. 

Wake Up the device by removing the cover. 

2. 

The hit the tamper switch once.

Send a wake-up notification.

In order to send your sensors new configuration commands from your Z-Wave controller or gateway, it will need to be

woken up. 

1. 

Wake Up the device by removing the cover. 

2. 

The hit the tamper switch once, led blinks short green.

Note: Door / Window Sensor 7 Pro remains awake until the housing is closed again.

Aeotec Door/Windows Sensor 7 Pro User guide : Aeotec Help Desk

https://aeotec.freshdesk.com/support/solutions/articles/6000230465

8 z 14

23. 2. 2021, 19:15

Summary of Contents for 7 Pro ZWA012

Page 1: ...be compatible with your Z Wave system or not please reference our Z Wave gateway comparison http aeotec com z wave gateways listing The https aeotec freshdesk com a solutions articles 6000218908 door...

Page 2: ...lames and extreme heat Avoid direct sunlight or heat exposure Always remove all batteries from products that are being stored and not used Batteries may damage the appliance if they leak Do not use re...

Page 3: ...Mounting can be accomplished either using the tape by peeling off the protection foil or using two screws with the holes inside the battery compartment If the tilt detection on a window only normal w...

Page 4: ...e windows where the window sits on top of the window frame mounting on the side of the window is highly recommended The sensor can be placed on any position of the door or the window Installation of t...

Page 5: ...n command class to indicate a change in state to the Z Wave controller that it is paired to By default the magnetic sensor is used instead of the Dry Contact Sensor If the unit was changed to a dry co...

Page 6: ...Aeotec Door Windows Sensor 7 Pro User guide Aeotec Help Desk https aeotec freshdesk com support solutions articles 6000230465 6 z 14 23 2 2021 19 15...

Page 7: ...ed to any type of sensor utilizing NO Normally Open dry contact sensors This can be used to detect water magnet positions tilt doorbells etc You can wire any dry contact sensor output to Terminal 2 an...

Page 8: ...Contact Pressed 2 time 3 Contact Pressed 3 time 4 Contact Pressed 4 time 5 Contact Pressed 5 time 6 Contact held down 7 Contact released Firmware Update over the Air This device is capable of receivin...

Page 9: ...and hold tamper switch for 5 seconds until the red LED blinks 3 Release the tamper switch 4 Immediately press and hold the tamper switch again a green LED will confirm reset Association Groups Associa...

Page 10: ...state will allow state of sensor to toggle OPEN CLOSE based on ON toOFF signal Parameter 3 Door Window State This parameter allows setting Door Window Sensor 7 state when the magnet is close to the se...

Page 11: ...Parameter 8 Values of ON command frame sent to Group 2 Association The value of 0 turns OFF the device 255 turns it On In the case of associating the Dimmer or Roller Shutter module values Size 1 Byt...

Page 12: ...Size 1 Byte Default Value 1 Setting Description 0 do not send tamper cancellation report 1 send tamper cancellation report Parameter 14 Central Scene Event Functionality This parameter enables disabl...

Page 13: ...1 Byte Default Value 2 Setting Description 0 On 1 Off 2 On and Off Parameter 19 BASIC command value sent to 5th Association Group on On event This is the BASIC command value sent in case of On event S...

Page 14: ...Setting Description 0 100 Time in seconds Parameter 255 Factory reset This parameter helps reset configuration parameters and the device to factory defaults Size 1 Byte Default Value 0 Setting Descrip...

Reviews: