1. Place your gateway or controller into Z-Wave unpair or exclusion mode. (Please refer to your controller/gateway
manual on how to do this)
2. Press the Action Button on your Switch.
3. If your switch has been successfully unlinked to your network, its LED will begin to blink. If linking was unsuccessful,
the LED will return to its last LED state.

If you are using a Z-Stick:

1. If your Z-Stick is plugged into a gateway or a computer, unplug it.
2. Take your Z-Stick to your Heavy Duty Smart Switch.
3. Press the Action Button on your Z-Stick.
4. Press the Action Button on your Heavy Duty Smart Switch.
5. If your Heavy Duty Smart Switch has been successfully removed from  your network, its Status LE D will blink. If the
removal was unsuccessful, its Status LED will not blink. 
6. Press the Action Button on your Z-Stick to take it out of removal mode.

If you are using a Minimote:

1. Take your Minimote to your Heavy Duty Smart Switch.
2. Press the Remove Button on your Minimote.
3. Press the Action Button on your Heavy Duty Smart Switch.
4. If your Heavy Duty Smart Switch has been successfully removed from  your network, its Status LED will blink. If the
removal was unsuccessful, its Status LED will not blink. 
5. Press any button on your Minimote to take it out of removal mode.

Turn your Heavy Duty Smart Switch Gen5 on or off.

Your Heavy Duty Smart Switch can be turned on or off through the use of  Z-Wave commands built into Z- Wave certified
controllers and gateways. The specific Z-Wave commands supporting this function are the Basic Command Class and
Binary Switch Command Class. Please consult the operation manual for your Z-Wave network controller for specific
instructions on controlling your Heavy Duty Smart Switch.

Monitoring power consumption.

Your Heavy Duty Smart Switch can report Watts energy usage or kWh energy usage to a Z-Wave gateway or controller. If
this function is supported by the gateway/controller, your energy consumption will be displayed within its user interface. The
specific Z-Wave commands supporting energy monitoring are the Meter Command Class and Multilevel Sensor Command
Class. Automatic reports go to association group 1, which is setup via the  Association Command Class. Please consult
your gateway/controller manual for instructions on monitoring energy consumption through your Heavy Duty Smart Switch.

More advanced configurations.

The Smart Switch Gen5 has a longer list of device configurations that you can do with Smart Switch Gen5. These are not
exposed well in most gateways, but at the least you can manually set configurations through most Z-Wave gateways
available. These configuration options may not be available in a few gateways.

You can find the configuration sheet here: https://aeotec.freshdesk.com/helpdesk/attachments/6009584699

(https://aeotec.freshdesk.com/helpdesk/attachments/6009584699)

Summary of Contents for Aeotec Heavy Duty Smart Switch Gen5

Page 1: ...com z wave plus It is powered by Aeotec s Gen5 http aeotec com z wave gen5 technology To see whether Heavy Duty Smart Switch Gen5 is known to be compatible with your Z Wave system or not please refere...

Page 2: ...ink slowly constantly Terminals There are two groups of terminals As marked mains power is to be connected to AC Power and the electric load to Load Important A licensed electrician with knowledge and...

Page 3: ...6000161813 heavy duty smart switch gen5 user guide 3 8 2 Loosen your Heavy Duty Smart Switch s lower screw to release its shell Remove the shell to reveal the inner electronics 3 Prepare the wires you...

Page 4: ...onding terminals marked L1 AND L2 on your Heavy Duty Smart Switch If there is a Neutral line and GND from the Air Break Switch please respectively connect them to the terminals labelled N and GND Simi...

Page 5: ...uld install repair or open your switch s casing Alternative Wiring Schematics You may find other wiring schematics for using 120VAC 1 phase 240VAC 2 phase or EU based applications here Wiring Schemati...

Page 6: ...to blink Repeat the above steps 7 Press the Action Button on your Z Stick to take it out of installation mode If you re using a Minimote 1 Decide on where you want your Heavy Duty Smart Switch to be p...

Page 7: ...nimote to take it out of removal mode Turn your Heavy Duty Smart Switch Gen5 on or off Your Heavy Duty Smart Switch can be turned on or off through the use of Z Wave commands built into Z Wave certifi...

Page 8: ...ide Aeotec by Aeon Labs https aeotec freshdesk com support solutions articles 6000161813 heavy duty smart switch gen5 user guide 8 8 If you have any questions on how to set these please contact suppor...

Reviews: