In regards to IEC 60446 wiring color mark standards in the EU where only Neutral, L1, and Ground are present
(L2 and L3 do not exist for the EU model):
N = Blue
L1 = Brown
GND = Yellow-Green
4. Wire your Heavy Duty Smart Switch according to the following diagram. As shown below, connect each live lines
from Air Break Switch to the corresponding terminals marked L1 AND L2 on your Heavy Duty Smart Switch. If there is a
Neutral line and GND from the Air Break Switch, please respectively connect them to the terminals labelled N and
GND. Similarly, wire the electric load with your Heavy Duty Smart Switch. As a final step, tighten the screws to the wire
terminals. (Note: Air Breaker is the same as Circuit Breaker)
Important: You must make sure the wire terminals are connected firmly with each corresponding terminal on your
Heavy Duty Smart Switch.
Please pay attention to the power and current of equipment. If the current is less than 32A, you can use AWG10 wire. If the
current exceeds 32A, please use AWG8 wire.
Warning: Device current can not exceed 40A.