Value
Description
1 — 15300 sec (Default 240)
Enable motion sensor (Parameter Number 4, Parameter Size 1)
Value
Description
0
Disabled
1
Enabled (Default)
Send unsolicited reports periodicaly. Interval group 1 (Parameter Number 101, Parameter Size 4)
Which reports need to send automatically in timing intervals for group 1
Value
Description
0
Battery report (Default)
5
Temperature
6
Luminosity
7
Humidity
Send unsolicited reports periodicaly. Intervcal group 2 (Parameter Number 102, Parameter Size 4)
Which reports need to send automatically in timing intervals for group 2
Value
Description
0
Battery report (Default)
5
Temperature
6
Luminosity
7
Humidity
Send unsolicited reports periodicaly. Intervcal group 3 (Parameter Number 103, Parameter Size 4)
Which reports need to send automatically in timing intervals for group 3
Value
Description
0
Battery report (Default)
5
Temperature
6
Luminosity
7
Humidity
(c) 2016 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 6