background image

Unsolicitate reports interval for timing groups 1 (Parameter Number 111, Parameter Size 4) Interval to send 

out reports to timing group 1

Value

Description

1 — 

2678400

sec (Default 720)

Unsolicitate reports interval for timing groups 2 (Parameter Number 112, Parameter Size 4) Interval to send 

out reports to timing group 2

Value

Description

1 — 

2678400

sec (Default 720)

Unsolicitate reports interval for timing groups 3 (Parameter Number 113, Parameter Size 4) Interval to send 

out reports to timing group 3

Value

Description

1 — 

2678400

sec (Default 720)

Technical Data

(c) 2016 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 7 

Summary of Contents for AEO MULTISENS

Page 1: ...en the sensor detects IR changes in front of its viewing window The Aeon Labs Multisensor complies with the IP43 standard so it can be used outdoors By adjusting the sensitivity of the sensor you can avoid the triggering due to small animals like dogs or cats The Aeon Labs Multi Sensor is delivered with a swivelling Back Mount Arm for wall mount and a Back Mount Plate for ceiling mount Installatio...

Page 2: ...and rain b For ceiling mount use the screws with the Back Mount Plate 4 Mount the Multisensor on the Mount Plate by rotating it clockwise to the Lock sign The next pictures are showing the effective motion sensor range for ceiling and wall mounting c 2016 Z Wave Europe GmbH Antonstr 3 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 2 ...

Page 3: ...r controller into inclusion or exclusion mode Only if the primary controller is in inclusion or exclusion mode this device can join or leave the network Leaving the network i e being excluded sets the device back to factory default If the device already belongs to a network follow the exclusion process before including it in your network Otherwise inclusion of this device will fail If the controll...

Page 4: ...tate by sending out a so called Wakeup Notification The controller can then empty the mailbox Therefore the device needs to be configured with the desired wakeup interval and the node ID of the controller If the device was included by a static controller this controller will usually perform all necessary configurations The wakeup interval is a tradeoff between maximal battery life time and the des...

Page 5: ...et values in the range 128 255 the value sent in the application shall be the desired value minus 256 For example to set a parameter to 200 it may be needed to set a value of 200 minus 256 minus 56 In case of two byte value the same logic applies Values greater than 32768 may needed to be given as negative values too Sensor report type on Get without instances Parameter Number 1 Parameter Size 1 W...

Page 6: ...olicited reports periodicaly Intervcal group 2 Parameter Number 102 Parameter Size 4 Which reports need to send automatically in timing intervals for group 2 Value Description 0 Battery report Default 5 Temperature 6 Luminosity 7 Humidity Send unsolicited reports periodicaly Intervcal group 3 Parameter Number 103 Parameter Size 4 Which reports need to send automatically in timing intervals for gro...

Page 7: ...meter Number 112 Parameter Size 4 Interval to send out reports to timing group 2 Value Description 1 2678400 sec Default 720 Unsolicitate reports interval for timing groups 3 Parameter Number 113 Parameter Size 4 Interval to send out reports to timing group 3 Value Description 1 2678400 sec Default 720 Technical Data c 2016 Z Wave Europe GmbH Antonstr 3 09337 Hohenstein Ernstthal Germany All right...

Page 8: ...r Frame Support No SDK 5 03 Device Type Slave with routing capabilities Generic Device Class Multilevel Sensor Specific Device Class Routing Multilevel Sensor Routing Yes FLiRS No Firmware Version 1 18 c 2016 Z Wave Europe GmbH Antonstr 3 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 8 ...

Reviews: