background image

3.

1.

2.

Put all the parts back in reverse order.

4.

5.

6.

The power supply must be cut off before changing carbon brushes.

9.

7.

8.

Carbon Brush

Wall-mounting Bracket

Fix the retaining screws in broken line 

showed in the picture; examine the strength 

and stability after works done.

The wall which you want to attach the bracket 

to must be a solid wall which could bear 

weight loading!

Groomers’ Third Arm

1.

2.

Fix the nozzle with the metal clamp.

Remove the retaining 

screws on front cap by 

cross screwdriver in arrow 

direction, and open the 

front cap.

Lift the little iron panel up 

with flathead screwdriver, 

open the brass clip which 

holds the motor wire to 

remove the old carbon 

brushes.

Put the new brushes 

in, and tighten the 

brass clip with nipper 

pliers to fix the 

varnished wires.

Twist the little iron to a 

certain angle to fix the 

carbon brush brass 

rear cap.

Remove the 4 wires 

from the connection 

terminal.

Remove the three 

screws which fix the 

front motor bracket one 

by one.

Slide out the rear motor 

bracket by fitting the little gap 

on the bracket to the screws 

on the housing.

After the middle rubber 

ring and rear motor 

bracket taken out, 

remove the rear motor.

Change carbon brushed 

on the rear motor 

according to the 

instructions in box 4, 5, 6

Summary of Contents for HERCULES TD-900XT

Page 1: ...anghai Xunyuan Industrial Co Ltd Address Building 8 No 65 Huandong First Road Jinshan District Shanghai China Distributor Contacts Owner s Guide New Generation TD 900XT PET DRYER ave Energy And Eco friendly dvanced Safety Control Technology xtremely Strong Blow Force nbelievable Super High Wind Speed TD 901T TD 903 TD 900XT TD 900CG TD 905 TD 906 TD 907 ...

Page 2: ...Nut Long Housing Housing Rubber Foot Handle Set PA3 10 Self tapping Screw Washer M5 10 Screw Vibration Absorber Ring Motor A Rubber Washer Carbon Brush Dual Motor Fixture Bracket Middle Rubber Ring 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 TD 90001 TD 90002 TD 90003 TD 90004 TD 90005 TD 90006 TD 90007 TD 90008 TD 90009 TD 90047 T...

Page 3: ...ean and dry and use a dry and soft cloth to clean the painted surface 3 Wet cloth with neutral detergent and wipe to remove stubborn stains and dirt 4 Use only mild neutral detergent 5 When the carbon brushes run out please renew the brushes following the guide line in this booklet or consult with the professionals Direction for Use Safety Instruction Pet dryer needs a single outlet which is at le...

Page 4: ... open the front cap Lift the little iron panel up with flathead screwdriver open the brass clip which holds the motor wire to remove the old carbon brushes Put the new brushes in and tighten the brass clip with nipper pliers to fix the varnished wires Twist the little iron to a certain angle to fix the carbon brush brass rear cap Remove the 4 wires from the connection terminal Remove the three scr...

Reviews: