background image

 

 

PARAMETER 

FUNCTION 

Date / Time

 

Sets the date and time format

 

Display

 

Adjusts the contrast and brightness of the display 

Defines the color of the voltage and current curves

 

Calculation Methods

 

Determines whether or not harmonics are used in calculations of 

reactive quantities (power and energy)

 

 

With harmonics: 

Harmonics are taken into account when 

calculating reactive parameters.

  

 

Without harmonics: 

Only the fundamental part is used for the 

calculation of reactive parameters

 

Electrical Connection

 

Determines the type of connection to the network

 

 

Single-Phase

 

 

Split-Phase

 

 

3-Phase 4-Wire

 

 

3-Phase 5-Wire

 

Sensors & Ratios

 

Defines the type of current probe to connect

 

 

MN93:  200A

AC

 

 

MN193: 100A or 5A

AC

 (with variable ratio)

  

 

SR193: 1000A

AC

 

 

J93: 3500A

AC

/5000A

DC

 

 

AmpFlex

®

 Sensors: 6500A

AC

 

 

MiniFlex

®

 Sensors: 6500A

AC

 

 

MR193: 1000A/1200A

AC/DC

 

 

SL261: 100A (sensitivity

 

10mV/A

AC/DC

)  

             10A (sensitivity 100mV/A

AC/DC

)

 

 

5A three-phase adapter (3-channel only)

  

Transient Mode

 

Configures the voltage and current thresholds

 

Trend (Recording) 

Mode

 

Selects the parameters to record (up to 4 configurations)

 

Alarm Mode

 

Defines the parameters of an alarm

 

Erase Memory

 

Deletes configurations, alarm settings, snapshots and recordings

 

About

 

Displays the serial number, software and hardware version

 

 

 

 

Summary of Contents for PowerPad 8436

Page 1: ...1 IMPORTANT WARRANTY NOTE By registering online within 30 days from the date of purchase your warranty will be extended to 3 years PowerPad Model8436 Quick StartGuide ENGLISH www aemc com...

Page 2: ...73 1 110V Power Cord Cat 5000 63 1 5 ft USB Cable Cat 2140 46 12 Color coded ID Markers Cat 2140 45 Also Included USB drive DataView User Manual 9 6V NiMh Battery installed SD Card installed High Vol...

Page 3: ...he time of purchase or obtained by returning the instrument to our repair and calibration facility for a nominal charge The recommended calibration interval for this instrument is 12 months and begins...

Page 4: ...hint to read The CE marking guarantees conformity with European directives and with regulations covering EMC The trash can with a line through it means that in the European Union the product must und...

Page 5: ...tegory exceeds those mentioned Do not use the instrument if it appears to be damaged incomplete or poorly closed Before each use check the condition of the insulation on the leads housing and accessor...

Page 6: ...n the memory Open a Help screen describing the current function Transients or Inrush Current Waveform acquisition mode with two sub modes transients mode blackouts interference etc and inrush current...

Page 7: ...c Power Energy Displays power levels and the associated parameters power factor displacement and tangent Energy monitoring Four quadrant measurement to discern source load active energy and inductive...

Page 8: ...onfigured the first time it is used The configuration is saved in memory when the instrument is turned OFF The instrument configurations can also be modified through the DataView software 1 Press the...

Page 9: ...n to the network Single Phase Split Phase 3 Phase 4 Wire 3 Phase 5 Wire Sensors Ratios Defines the type of current probe to connect MN93 200AAC MN193 100A or 5AAC with variable ratio SR193 1000AAC J93...

Page 10: ...he cover back on Getting Started NOTE Ensure the PowerPad is fully charged before use Connecting 1 Press the button to turn the instrument ON 2 Configure the instrument to obtain the required results...

Page 11: ...iew the files on the drive 3 In the AutoPlay window select Open folder to view files 4 Double click on Setup exe from the opened folder view to launch the Dataview setup program For more information o...

Page 12: ...for calibration weneed to know if you want a standard calibration or a calibration traceable to N I S T Includescalibration certificate plus recorded calibration data Ship To Chauvin Arnoux Inc d b a...

Page 13: ...y return the instrument to us for repair provided we have your warranty registration on file or a proof of purchase AEMC Instruments will at its option repair or replace the faulty material Warranty R...

Page 14: ...14 NOTES...

Page 15: ...15 NOTES...

Page 16: ...16 02 19 99 MAN 100483 v1 Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 603 749 6434 Fax 603 742 2346 www aemc com...

Reviews: